WEKO3
アイテム
{"_buckets": {"deposit": "445dc8eb-4597-4d09-9d1a-04cb0418c1fc"}, "_deposit": {"created_by": 1, "id": "57361", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "57361"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00057361", "sets": ["11"]}, "author_link": ["579735", "579736", "579733", "579738", "579732", "579731", "579730", "579734", "579737", "579729"], "item_10004_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2007-10", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2", "bibliographicPageEnd": "63", "bibliographicPageStart": "57", "bibliographicVolumeNumber": "12", "bibliographic_titles": [{"bibliographic_title": "医用標準線量"}]}]}, "item_10004_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "放医研に設置されているソフテックス株式会社製M-70-WE特型X線発生装置は、照射用として最大管電圧が70kVのX線が得られる。 今回放射線防護薬の研究として、マウス皮膚の放射線障害と防護薬の研究の利用のため、軟X線照射場のドシメトリーを行った。浅い皮膚面の傷害に対する影響を研究するため、30kVpX線を選定して特性を検討し照射場を決定した。照射管電圧の決定、付加フィルター零とPMMA0.5mm通過後の半価層、照射ビームの実効エネルギー、照射野の線量分布、深部線量分布の検討、測定電離箱の校正定数、マウス照射ケージの決定、マウス皮膚における水吸収線量の決定、など測定および検討結果について述べる。", "subitem_description_type": "Abstract"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "平岡, 武"}], "nameIdentifiers": [{"nameIdentifier": "579729", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "三井, 大輔"}], "nameIdentifiers": [{"nameIdentifier": "579730", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "石川, 剛弘"}], "nameIdentifiers": [{"nameIdentifier": "579731", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "濱野, 毅"}], "nameIdentifiers": [{"nameIdentifier": "579732", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "宮原, 信幸"}], "nameIdentifiers": [{"nameIdentifier": "579733", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "平岡 武", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "579734", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "三井 大輔", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "579735", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "石川 剛弘", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "579736", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "濱野 毅", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "579737", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "宮原 信幸", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "579738", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "軟X線の線量測定", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "軟X線の線量測定"}]}, "item_type_id": "10004", "owner": "1", "path": ["11"], "permalink_uri": "https://repo.qst.go.jp/records/57361", "pubdate": {"attribute_name": "公開日", "attribute_value": "2008-02-08"}, "publish_date": "2008-02-08", "publish_status": "0", "recid": "57361", "relation": {}, "relation_version_is_last": true, "title": ["軟X線の線量測定"], "weko_shared_id": -1}
軟X線の線量測定
https://repo.qst.go.jp/records/57361
https://repo.qst.go.jp/records/57361f9cda757-4b86-4950-8fd9-0eefd2c76110
Item type | 一般雑誌記事 / Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2008-02-08 | |||||
タイトル | ||||||
タイトル | 軟X線の線量測定 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
平岡, 武
× 平岡, 武× 三井, 大輔× 石川, 剛弘× 濱野, 毅× 宮原, 信幸× 平岡 武× 三井 大輔× 石川 剛弘× 濱野 毅× 宮原 信幸 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 放医研に設置されているソフテックス株式会社製M-70-WE特型X線発生装置は、照射用として最大管電圧が70kVのX線が得られる。 今回放射線防護薬の研究として、マウス皮膚の放射線障害と防護薬の研究の利用のため、軟X線照射場のドシメトリーを行った。浅い皮膚面の傷害に対する影響を研究するため、30kVpX線を選定して特性を検討し照射場を決定した。照射管電圧の決定、付加フィルター零とPMMA0.5mm通過後の半価層、照射ビームの実効エネルギー、照射野の線量分布、深部線量分布の検討、測定電離箱の校正定数、マウス照射ケージの決定、マウス皮膚における水吸収線量の決定、など測定および検討結果について述べる。 | |||||
書誌情報 |
医用標準線量 巻 12, 号 2, p. 57-63, 発行日 2007-10 |