{"_buckets": {"deposit": "89422b8f-fa83-4e5b-aaf1-4e47d1cf276a"}, "_deposit": {"created_by": 1, "id": "56392", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "56392"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00056392", "sets": ["11"]}, "author_link": ["575442", "575441", "575440", "575443"], "item_10004_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2003", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1", "bibliographicPageEnd": "16", "bibliographicPageStart": "11", "bibliographicVolumeNumber": "14", "bibliographic_titles": [{"bibliographic_title": "Biomedical Research on Trace Elements"}]}]}, "item_10004_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Abstract Particle Induced X-ray Emission(PIXE)analysis is one of the analytical methods for elements. PIXE has high sensitivity, multi-elemental and non-destructive characteristics and the advantage of micro-beam scanning ability on the sample surface. In 1999, micro-beam scanning PIXE system was installed at the National Institute of Radiological Sciences (NIRS). The system allowed multi elemental mapping on 2mm x 2mm areas of small samples such as fish scales, small fish eyes, pollen etc. with a special resolution of about 1mu m with accelerated proton micro-beams produced by an electrostatic accelerator, Tandetron (Model 4117MC, High Voltage Engineering Europe Co.) and a micro-beam scanning system (Model OM2000, Oxford Micro Beams, Ltd.).\n Fine ring structure of a fish scale was observed with P and Ca maps. Pollen was examined to ability of the system to draw elemental distribution maps of singles cell. The distribution of elements in a thin section of Medaka eye was investigated in connection with Scanning Transmission Ion Microscopy (STIM).", "subitem_description_type": "Abstract"}]}, "item_10004_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0916-717X", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Yukawa, Masae"}], "nameIdentifiers": [{"nameIdentifier": "575440", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Imaseki, Hitoshi"}], "nameIdentifiers": [{"nameIdentifier": "575441", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "湯川 雅枝", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "575442", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "今関 等", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "575443", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Imaging of elemental distribution in the small area of biological samples- micro-PIXE analysis", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Imaging of elemental distribution in the small area of biological samples- micro-PIXE analysis"}]}, "item_type_id": "10004", "owner": "1", "path": ["11"], "permalink_uri": "https://repo.qst.go.jp/records/56392", "pubdate": {"attribute_name": "公開日", "attribute_value": "2003-05-16"}, "publish_date": "2003-05-16", "publish_status": "0", "recid": "56392", "relation": {}, "relation_version_is_last": true, "title": ["Imaging of elemental distribution in the small area of biological samples- micro-PIXE analysis"], "weko_shared_id": -1}
Imaging of elemental distribution in the small area of biological samples- micro-PIXE analysis
https://repo.qst.go.jp/records/56392
https://repo.qst.go.jp/records/56392a18b706e-39c1-464f-a670-8ad2446a5ac3
Item type | 一般雑誌記事 / Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2003-05-16 | |||||
タイトル | ||||||
タイトル | Imaging of elemental distribution in the small area of biological samples- micro-PIXE analysis | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Yukawa, Masae
× Yukawa, Masae× Imaseki, Hitoshi× 湯川 雅枝× 今関 等 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Abstract Particle Induced X-ray Emission(PIXE)analysis is one of the analytical methods for elements. PIXE has high sensitivity, multi-elemental and non-destructive characteristics and the advantage of micro-beam scanning ability on the sample surface. In 1999, micro-beam scanning PIXE system was installed at the National Institute of Radiological Sciences (NIRS). The system allowed multi elemental mapping on 2mm x 2mm areas of small samples such as fish scales, small fish eyes, pollen etc. with a special resolution of about 1mu m with accelerated proton micro-beams produced by an electrostatic accelerator, Tandetron (Model 4117MC, High Voltage Engineering Europe Co.) and a micro-beam scanning system (Model OM2000, Oxford Micro Beams, Ltd.). Fine ring structure of a fish scale was observed with P and Ca maps. Pollen was examined to ability of the system to draw elemental distribution maps of singles cell. The distribution of elements in a thin section of Medaka eye was investigated in connection with Scanning Transmission Ion Microscopy (STIM). |
|||||
書誌情報 |
Biomedical Research on Trace Elements 巻 14, 号 1, p. 11-16, 発行日 2003 |
|||||