WEKO3
アイテム
{"_buckets": {"deposit": "1b108293-3c01-4335-815d-9ae42d446c5c"}, "_deposit": {"created_by": 1, "id": "56028", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "56028"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00056028", "sets": ["7"]}, "author_link": ["573327", "573325", "573328", "573324", "573323", "573326"], "item_10004_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2017-03", "bibliographicIssueDateType": "Issued"}, "bibliographicPageStart": "166", "bibliographic_titles": [{"bibliographic_title": "QST Takasaki Annual Report 2015"}]}]}, "item_10004_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "We investigated the beam intensity range of several different phosphor screens for efficient real-time tuning of a large-area ion-beam distribution at the TIARA cyclotron. It has been found that high-intensity beams can be monitored using calcium fluoride and PEN films of different thicknesses for light ions. The intensity range is 10^-3~10^1 nA/cm^2 for 10-MeV protons. As a result, a large-area uniform ion beam can be adjusted efficiently at a high intensity of the order of 10 nA/cm^2, which is often required for radiation degradation/damage testing of materials.", "subitem_description_type": "Abstract"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "百合, 庸介"}], "nameIdentifiers": [{"nameIdentifier": "573323", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "湯山, 貴裕"}], "nameIdentifiers": [{"nameIdentifier": "573324", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "石坂, 知久"}], "nameIdentifiers": [{"nameIdentifier": "573325", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "百合 庸介", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "573326", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "湯山 貴裕", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "573327", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "石坂 知久", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "573328", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Investigation of Phosphor Screens for Real-time Tuning of Large-area Ion Beam Profile", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Investigation of Phosphor Screens for Real-time Tuning of Large-area Ion Beam Profile"}]}, "item_type_id": "10004", "owner": "1", "path": ["7"], "permalink_uri": "https://repo.qst.go.jp/records/56028", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-03-30"}, "publish_date": "2017-03-30", "publish_status": "0", "recid": "56028", "relation": {}, "relation_version_is_last": true, "title": ["Investigation of Phosphor Screens for Real-time Tuning of Large-area Ion Beam Profile"], "weko_shared_id": -1}
Investigation of Phosphor Screens for Real-time Tuning of Large-area Ion Beam Profile
https://repo.qst.go.jp/records/56028
https://repo.qst.go.jp/records/5602806ae6ac6-33cf-47e2-9c69-20038bc92fa4
Item type | 一般雑誌記事 / Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-03-30 | |||||
タイトル | ||||||
タイトル | Investigation of Phosphor Screens for Real-time Tuning of Large-area Ion Beam Profile | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
百合, 庸介
× 百合, 庸介× 湯山, 貴裕× 石坂, 知久× 百合 庸介× 湯山 貴裕× 石坂 知久 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | We investigated the beam intensity range of several different phosphor screens for efficient real-time tuning of a large-area ion-beam distribution at the TIARA cyclotron. It has been found that high-intensity beams can be monitored using calcium fluoride and PEN films of different thicknesses for light ions. The intensity range is 10^-3~10^1 nA/cm^2 for 10-MeV protons. As a result, a large-area uniform ion beam can be adjusted efficiently at a high intensity of the order of 10 nA/cm^2, which is often required for radiation degradation/damage testing of materials. | |||||
書誌情報 |
QST Takasaki Annual Report 2015 p. 166, 発行日 2017-03 |