WEKO3
アイテム
{"_buckets": {"deposit": "c6631362-6156-4e52-836d-ad755104eed4"}, "_deposit": {"created_by": 1, "id": "55631", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "55631"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00055631", "sets": ["7"]}, "author_link": ["569242", "569244", "569245", "569249", "569243", "569241", "569240", "569246", "569248", "569247"], "item_10004_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2008-09", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "NIRS-M-215", "bibliographicPageEnd": "74", "bibliographicPageStart": "68", "bibliographicVolumeNumber": "2008", "bibliographic_titles": [{"bibliographic_title": "放射線医学総合研究所技術報告書"}]}]}, "item_10004_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "2008年3月上旬、放医研X線棟第3照射室に前X線照射装置PANTAK HF-320型の後継機としてX線発生装置TITAN-320型が設置された。装置更新に伴い、X線発生装置TITAN-320型の線量測定を実施した。 X線管焦点と照射台間距離(FSD)を変更することによって、3.51〜0.21Gy/minの範囲で照射が可能であり、高線量照射用回転テーブルを照射台に設置すると5.00Gy/min以上の(FSD235mm、照射野100mm)での照射が可能であることが確認された。", "subitem_description_type": "Abstract"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "三井, 大輔"}], "nameIdentifiers": [{"nameIdentifier": "569240", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "酢屋, 徳啓"}], "nameIdentifiers": [{"nameIdentifier": "569241", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "石川, 剛弘"}], "nameIdentifiers": [{"nameIdentifier": "569242", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "磯, 浩之"}], "nameIdentifiers": [{"nameIdentifier": "569243", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "今関, 等"}], "nameIdentifiers": [{"nameIdentifier": "569244", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "三井 大輔", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "569245", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "酢屋 徳啓", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "569246", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "石川 剛弘", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "569247", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "磯 浩之", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "569248", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "今関 等", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "569249", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "X線発生装置TITAN-320型における線量測定結果", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "X線発生装置TITAN-320型における線量測定結果"}]}, "item_type_id": "10004", "owner": "1", "path": ["7"], "permalink_uri": "https://repo.qst.go.jp/records/55631", "pubdate": {"attribute_name": "公開日", "attribute_value": "2008-10-24"}, "publish_date": "2008-10-24", "publish_status": "0", "recid": "55631", "relation": {}, "relation_version_is_last": true, "title": ["X線発生装置TITAN-320型における線量測定結果"], "weko_shared_id": -1}
X線発生装置TITAN-320型における線量測定結果
https://repo.qst.go.jp/records/55631
https://repo.qst.go.jp/records/556310a748ef5-27ed-4c1f-a71f-7607d9038051
Item type | 一般雑誌記事 / Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2008-10-24 | |||||
タイトル | ||||||
タイトル | X線発生装置TITAN-320型における線量測定結果 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
三井, 大輔
× 三井, 大輔× 酢屋, 徳啓× 石川, 剛弘× 磯, 浩之× 今関, 等× 三井 大輔× 酢屋 徳啓× 石川 剛弘× 磯 浩之× 今関 等 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 2008年3月上旬、放医研X線棟第3照射室に前X線照射装置PANTAK HF-320型の後継機としてX線発生装置TITAN-320型が設置された。装置更新に伴い、X線発生装置TITAN-320型の線量測定を実施した。 X線管焦点と照射台間距離(FSD)を変更することによって、3.51〜0.21Gy/minの範囲で照射が可能であり、高線量照射用回転テーブルを照射台に設置すると5.00Gy/min以上の(FSD235mm、照射野100mm)での照射が可能であることが確認された。 | |||||
書誌情報 |
放射線医学総合研究所技術報告書 巻 2008, 号 NIRS-M-215, p. 68-74, 発行日 2008-09 |