{"_buckets": {"deposit": "5afcb55d-7161-4d83-83a5-f4a382a5f479"}, "_deposit": {"created_by": 1, "id": "55627", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "55627"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00055627", "sets": ["7"]}, "author_link": ["569207", "569206", "569189", "569196", "569199", "569190", "569191", "569200", "569203", "569198", "569204", "569192", "569195", "569193", "569205", "569201", "569202", "569194", "569197", "569188"], "item_10004_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2008-09", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "NIRS-M-215", "bibliographicPageEnd": "91", "bibliographicPageStart": "85", "bibliographicVolumeNumber": "2008", "bibliographic_titles": [{"bibliographic_title": "放射線医学総合研究所技術報告書"}]}]}, "item_10004_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "研究基盤技術部放射線発生装置利用技術開発課では、平成15年度に速中性子線照射用加速器システムNeutron Exposure Accelerator System for Biological Effect Experiment(以下NASBEE)を導入した。このシステムは、加速された水素及び重水素イオンをBeやLi等の固体金属ターゲットに照射し、発生する高フルエンスの速中性子をコンベンショナルな環境下(生物照射室)及びSpecific Pathogen free(特定病原菌未感染:SPF)マウス、ラット等に照射することができることである。本システム導入時に新規に設計したBeターゲットが5年間で7個作成し内4個がビームの熱による劣化のため破損した。照射で使用した場合の平均期間は約半年程度とわかった。破損の状況により分かった幾つかの構造的欠点も修正したので、これについて報告する。", "subitem_description_type": "Abstract"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "萩原, 拓也"}], "nameIdentifiers": [{"nameIdentifier": "569188", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "須田, 充"}], "nameIdentifiers": [{"nameIdentifier": "569189", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "酢屋, 徳啓"}], "nameIdentifiers": [{"nameIdentifier": "569190", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小西, 輝昭"}], "nameIdentifiers": [{"nameIdentifier": "569191", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "濱野, 毅"}], "nameIdentifiers": [{"nameIdentifier": "569192", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "宮原, 信幸"}], "nameIdentifiers": [{"nameIdentifier": "569193", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "高田, 真志"}], "nameIdentifiers": [{"nameIdentifier": "569194", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "大町, 康"}], "nameIdentifiers": [{"nameIdentifier": "569195", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "平岡, 武"}], "nameIdentifiers": [{"nameIdentifier": "569196", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "今関, 等"}], "nameIdentifiers": [{"nameIdentifier": "569197", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "萩原 拓也", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "569198", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "須田 充", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "569199", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "酢屋 徳啓", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "569200", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小西 輝昭", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "569201", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "濱野 毅", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "569202", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "宮原 信幸", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "569203", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "高田 真志", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "569204", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "大町 康", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "569205", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "平岡 武", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "569206", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "今関 等", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "569207", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "NASBEEに導入したBeターゲットの耐久性について(1)", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "NASBEEに導入したBeターゲットの耐久性について(1)"}]}, "item_type_id": "10004", "owner": "1", "path": ["7"], "permalink_uri": "https://repo.qst.go.jp/records/55627", "pubdate": {"attribute_name": "公開日", "attribute_value": "2008-10-21"}, "publish_date": "2008-10-21", "publish_status": "0", "recid": "55627", "relation": {}, "relation_version_is_last": true, "title": ["NASBEEに導入したBeターゲットの耐久性について(1)"], "weko_shared_id": -1}
NASBEEに導入したBeターゲットの耐久性について(1)
https://repo.qst.go.jp/records/55627
https://repo.qst.go.jp/records/55627b9efa593-1eac-45fa-b74b-fe3e0af1d17b
Item type | 一般雑誌記事 / Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2008-10-21 | |||||
タイトル | ||||||
タイトル | NASBEEに導入したBeターゲットの耐久性について(1) | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
萩原, 拓也
× 萩原, 拓也× 須田, 充× 酢屋, 徳啓× 小西, 輝昭× 濱野, 毅× 宮原, 信幸× 高田, 真志× 大町, 康× 平岡, 武× 今関, 等× 萩原 拓也× 須田 充× 酢屋 徳啓× 小西 輝昭× 濱野 毅× 宮原 信幸× 高田 真志× 大町 康× 平岡 武× 今関 等 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 研究基盤技術部放射線発生装置利用技術開発課では、平成15年度に速中性子線照射用加速器システムNeutron Exposure Accelerator System for Biological Effect Experiment(以下NASBEE)を導入した。このシステムは、加速された水素及び重水素イオンをBeやLi等の固体金属ターゲットに照射し、発生する高フルエンスの速中性子をコンベンショナルな環境下(生物照射室)及びSpecific Pathogen free(特定病原菌未感染:SPF)マウス、ラット等に照射することができることである。本システム導入時に新規に設計したBeターゲットが5年間で7個作成し内4個がビームの熱による劣化のため破損した。照射で使用した場合の平均期間は約半年程度とわかった。破損の状況により分かった幾つかの構造的欠点も修正したので、これについて報告する。 | |||||
書誌情報 |
放射線医学総合研究所技術報告書 巻 2008, 号 NIRS-M-215, p. 85-91, 発行日 2008-09 |