WEKO3
アイテム
{"_buckets": {"deposit": "ed3f26dc-faae-4cb2-b23c-bd0d4e8fae7f"}, "_deposit": {"created_by": 1, "id": "55563", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "55563"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00055563", "sets": ["7"]}, "author_link": ["568461", "568464", "568463", "568462"], "item_10004_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2006", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1", "bibliographicPageEnd": "31", "bibliographicPageStart": "25", "bibliographicVolumeNumber": "11", "bibliographic_titles": [{"bibliographic_title": "医用標準線量"}]}]}, "item_10004_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "代表的な人体組織のCT値を理論的に求め、人体組織のCT値、放射線治療計画用のX線スペクトル、ビームハードニングなどの基礎知識に役立てる。", "subitem_description_type": "Abstract"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "藤崎, 達也"}], "nameIdentifiers": [{"nameIdentifier": "568461", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "平岡, 武"}], "nameIdentifiers": [{"nameIdentifier": "568462", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "齋藤, 秀敏"}], "nameIdentifiers": [{"nameIdentifier": "568463", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "平岡 武", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "568464", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "各種人体組織のCT値−理論的な計算−", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "各種人体組織のCT値−理論的な計算−"}]}, "item_type_id": "10004", "owner": "1", "path": ["7"], "permalink_uri": "https://repo.qst.go.jp/records/55563", "pubdate": {"attribute_name": "公開日", "attribute_value": "2007-08-24"}, "publish_date": "2007-08-24", "publish_status": "0", "recid": "55563", "relation": {}, "relation_version_is_last": true, "title": ["各種人体組織のCT値−理論的な計算−"], "weko_shared_id": -1}
各種人体組織のCT値−理論的な計算−
https://repo.qst.go.jp/records/55563
https://repo.qst.go.jp/records/55563f636a215-7947-4714-8487-d5e19371078f
Item type | 一般雑誌記事 / Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2007-08-24 | |||||
タイトル | ||||||
タイトル | 各種人体組織のCT値−理論的な計算− | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
藤崎, 達也
× 藤崎, 達也× 平岡, 武× 齋藤, 秀敏× 平岡 武 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 代表的な人体組織のCT値を理論的に求め、人体組織のCT値、放射線治療計画用のX線スペクトル、ビームハードニングなどの基礎知識に役立てる。 | |||||
書誌情報 |
医用標準線量 巻 11, 号 1, p. 25-31, 発行日 2006 |