WEKO3
アイテム
{"_buckets": {"deposit": "99ce1b48-95bb-42de-8530-7f1c9641525b"}, "_deposit": {"created_by": 1, "id": "55255", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "55255"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00055255", "sets": ["7"]}, "author_link": ["565221", "565224", "565225", "565223", "565219", "565218", "565220", "565217", "565222"], "item_10004_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2003-04", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "106", "bibliographicPageStart": "105", "bibliographicVolumeNumber": "2002", "bibliographic_titles": [{"bibliographic_title": "放射線医学総合研究所重粒子線がん治療装置等共同利用研究報告書"}]}]}, "item_10004_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Colonogenic assays of normal human and Ataxia Telangiectasia fibroblast cells were performed using heavy ions. Survival data showed that AT was much more sensitive to low-LET radiations but showed similar sensitivity to high-LET radiations compared to normal human fibroblasts.", "subitem_description_type": "Abstract"}]}, "item_10004_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "放医研"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "川田, 哲也"}], "nameIdentifiers": [{"nameIdentifier": "565217", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "斎藤, 正好"}], "nameIdentifiers": [{"nameIdentifier": "565218", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "宇野, 隆"}], "nameIdentifiers": [{"nameIdentifier": "565219", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "古澤, 佳也"}], "nameIdentifiers": [{"nameIdentifier": "565220", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "伊東, 久夫"}], "nameIdentifiers": [{"nameIdentifier": "565221", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "川田 哲也", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "565222", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "宇野 隆", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "565223", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "古澤 佳也", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "565224", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "伊東 久夫", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "565225", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "ヒト繊維芽細胞の重粒子線照射による生存率とFISH法による染色体異常に関する研究", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "ヒト繊維芽細胞の重粒子線照射による生存率とFISH法による染色体異常に関する研究"}]}, "item_type_id": "10004", "owner": "1", "path": ["7"], "permalink_uri": "https://repo.qst.go.jp/records/55255", "pubdate": {"attribute_name": "公開日", "attribute_value": "2004-01-25"}, "publish_date": "2004-01-25", "publish_status": "0", "recid": "55255", "relation": {}, "relation_version_is_last": true, "title": ["ヒト繊維芽細胞の重粒子線照射による生存率とFISH法による染色体異常に関する研究"], "weko_shared_id": -1}
ヒト繊維芽細胞の重粒子線照射による生存率とFISH法による染色体異常に関する研究
https://repo.qst.go.jp/records/55255
https://repo.qst.go.jp/records/552550762ccdf-e289-4593-b0dc-165c13a929eb
Item type | 一般雑誌記事 / Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2004-01-25 | |||||
タイトル | ||||||
タイトル | ヒト繊維芽細胞の重粒子線照射による生存率とFISH法による染色体異常に関する研究 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
川田, 哲也
× 川田, 哲也× 斎藤, 正好× 宇野, 隆× 古澤, 佳也× 伊東, 久夫× 川田 哲也× 宇野 隆× 古澤 佳也× 伊東 久夫 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Colonogenic assays of normal human and Ataxia Telangiectasia fibroblast cells were performed using heavy ions. Survival data showed that AT was much more sensitive to low-LET radiations but showed similar sensitivity to high-LET radiations compared to normal human fibroblasts. | |||||
書誌情報 |
放射線医学総合研究所重粒子線がん治療装置等共同利用研究報告書 巻 2002, p. 105-106, 発行日 2003-04 |
|||||
出版者 | ||||||
出版者 | 放医研 |