WEKO3
アイテム
{"_buckets": {"deposit": "ba189fd1-39d6-4e42-8e3e-ef9f45195382"}, "_deposit": {"created_by": 1, "id": "55233", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "55233"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00055233", "sets": ["7"]}, "author_link": ["564947", "564946", "564950", "564942", "564949", "564948", "564945", "564937", "564941", "564936", "564943", "564935", "564939", "564944", "564938", "564940"], "item_10004_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2003-04", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "244", "bibliographicPageStart": "243", "bibliographic_titles": [{"bibliographic_title": "放射線医学総合研究所重粒子線がん治療装置等共同利用研究報告書"}]}]}, "item_10004_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "We have been developing a cosmic-ray detector. CALorimetric Electron Telescope (CALET), to observe high energy cosmic-ray electrons, gamma rays, and heavy particles on the International Space Station (ISS). The detector consists of two parts, an imaging calorimeter assembled with scintillating fibers and a total absorption calorimeter of BGO. We make tests of a scintillating fiber readout unit with beams of He (230MeV/n), C (430MeV/n), Si(800MeV/n) and Fe (500MeV/n) to investigate charge identification performace of it.", "subitem_description_type": "Abstract"}]}, "item_10004_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "放医研"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "田村, 忠久"}], "nameIdentifiers": [{"nameIdentifier": "564935", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "鳥居, 祥二"}], "nameIdentifiers": [{"nameIdentifier": "564936", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "日比野, 欣也"}], "nameIdentifiers": [{"nameIdentifier": "564937", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "吉田, 賢二"}], "nameIdentifiers": [{"nameIdentifier": "564938", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "奥野, 祥二"}], "nameIdentifiers": [{"nameIdentifier": "564939", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "内堀, 幸夫"}], "nameIdentifiers": [{"nameIdentifier": "564940", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "北村, 尚"}], "nameIdentifiers": [{"nameIdentifier": "564941", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "片寄, 祐作"}], "nameIdentifiers": [{"nameIdentifier": "564942", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "田村 忠久", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "564943", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "鳥居 祥二", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "564944", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "日比野 欣也", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "564945", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "吉田 賢二", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "564946", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "奥野 祥二", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "564947", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "内堀 幸夫", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "564948", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "北村 尚", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "564949", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "片寄 祐作", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "564950", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "スペースシャトル搭載用宇宙線観測装置の重粒子検出性能に関する研究 (12P-098)", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "スペースシャトル搭載用宇宙線観測装置の重粒子検出性能に関する研究 (12P-098)"}]}, "item_type_id": "10004", "owner": "1", "path": ["7"], "permalink_uri": "https://repo.qst.go.jp/records/55233", "pubdate": {"attribute_name": "公開日", "attribute_value": "2004-01-23"}, "publish_date": "2004-01-23", "publish_status": "0", "recid": "55233", "relation": {}, "relation_version_is_last": true, "title": ["スペースシャトル搭載用宇宙線観測装置の重粒子検出性能に関する研究 (12P-098)"], "weko_shared_id": -1}
スペースシャトル搭載用宇宙線観測装置の重粒子検出性能に関する研究 (12P-098)
https://repo.qst.go.jp/records/55233
https://repo.qst.go.jp/records/55233a22c6b9a-c2ca-45d2-bc0f-fd160ddff04e
Item type | 一般雑誌記事 / Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2004-01-23 | |||||
タイトル | ||||||
タイトル | スペースシャトル搭載用宇宙線観測装置の重粒子検出性能に関する研究 (12P-098) | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
田村, 忠久
× 田村, 忠久× 鳥居, 祥二× 日比野, 欣也× 吉田, 賢二× 奥野, 祥二× 内堀, 幸夫× 北村, 尚× 片寄, 祐作× 田村 忠久× 鳥居 祥二× 日比野 欣也× 吉田 賢二× 奥野 祥二× 内堀 幸夫× 北村 尚× 片寄 祐作 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | We have been developing a cosmic-ray detector. CALorimetric Electron Telescope (CALET), to observe high energy cosmic-ray electrons, gamma rays, and heavy particles on the International Space Station (ISS). The detector consists of two parts, an imaging calorimeter assembled with scintillating fibers and a total absorption calorimeter of BGO. We make tests of a scintillating fiber readout unit with beams of He (230MeV/n), C (430MeV/n), Si(800MeV/n) and Fe (500MeV/n) to investigate charge identification performace of it. | |||||
書誌情報 |
放射線医学総合研究所重粒子線がん治療装置等共同利用研究報告書 p. 243-244, 発行日 2003-04 |
|||||
出版者 | ||||||
出版者 | 放医研 |