WEKO3
アイテム
{"_buckets": {"deposit": "4f11f14c-268f-4bc7-a6f5-3ff2a3aba023"}, "_deposit": {"created_by": 1, "id": "55157", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "55157"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00055157", "sets": ["7"]}, "author_link": ["564318", "564313", "564320", "564312", "564314", "564317", "564315", "564319", "564316"], "item_10004_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2002-09", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "11/16", "bibliographicPageEnd": "28", "bibliographicPageStart": "23", "bibliographicVolumeNumber": "02", "bibliographic_titles": [{"bibliographic_title": "電気学会研究会資料 NE, 原子力研究会"}]}]}, "item_10004_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "ガンマ線源の分布測定装置としてのコンプトンカメラは、効率のよい分布測定装置として1970年代に提案され、近年まで比較的緩やかな発展が続けられたが、半導体放射線検出器の技術発展、及び、分子生物学分野での高分解能機能断層画像の要求を受け、ここ数年コンプトンカメラ関係の研究発表が多くなっている。本論文では、コンプトンカメラの原理と補正点、分布像再構成法、検出器構成例について解説する。", "subitem_description_type": "Abstract"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "平澤, 雅彦"}], "nameIdentifiers": [{"nameIdentifier": "564312", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "富谷, 武浩"}], "nameIdentifiers": [{"nameIdentifier": "564313", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "柴田, 貞夫"}], "nameIdentifiers": [{"nameIdentifier": "564314", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "榎本, 秀一"}], "nameIdentifiers": [{"nameIdentifier": "564315", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "矢野, 安重"}], "nameIdentifiers": [{"nameIdentifier": "564316", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "平澤 雅彦", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "564317", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "富谷 武浩", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "564318", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "柴田 貞夫", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "564319", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "矢野 安重", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "564320", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "コンプトンカメラによるガンマ線源分布測定技術とその動向", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "コンプトンカメラによるガンマ線源分布測定技術とその動向"}]}, "item_type_id": "10004", "owner": "1", "path": ["7"], "permalink_uri": "https://repo.qst.go.jp/records/55157", "pubdate": {"attribute_name": "公開日", "attribute_value": "2003-10-20"}, "publish_date": "2003-10-20", "publish_status": "0", "recid": "55157", "relation": {}, "relation_version_is_last": true, "title": ["コンプトンカメラによるガンマ線源分布測定技術とその動向"], "weko_shared_id": -1}
コンプトンカメラによるガンマ線源分布測定技術とその動向
https://repo.qst.go.jp/records/55157
https://repo.qst.go.jp/records/55157aa99e803-f906-4136-900e-2dad34c7e45f
Item type | 一般雑誌記事 / Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2003-10-20 | |||||
タイトル | ||||||
タイトル | コンプトンカメラによるガンマ線源分布測定技術とその動向 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
平澤, 雅彦
× 平澤, 雅彦× 富谷, 武浩× 柴田, 貞夫× 榎本, 秀一× 矢野, 安重× 平澤 雅彦× 富谷 武浩× 柴田 貞夫× 矢野 安重 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | ガンマ線源の分布測定装置としてのコンプトンカメラは、効率のよい分布測定装置として1970年代に提案され、近年まで比較的緩やかな発展が続けられたが、半導体放射線検出器の技術発展、及び、分子生物学分野での高分解能機能断層画像の要求を受け、ここ数年コンプトンカメラ関係の研究発表が多くなっている。本論文では、コンプトンカメラの原理と補正点、分布像再構成法、検出器構成例について解説する。 | |||||
書誌情報 |
電気学会研究会資料 NE, 原子力研究会 巻 02, 号 11/16, p. 23-28, 発行日 2002-09 |