WEKO3
アイテム
{"_buckets": {"deposit": "6dddabe8-260b-4169-95c4-27c7c5aa0cc5"}, "_deposit": {"created_by": 1, "id": "54985", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "54985"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00054985", "sets": ["7"]}, "author_link": ["562481", "562488", "562489", "562486", "562483", "562490", "562479", "562487", "562485", "562484", "562482", "562480"], "item_10004_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2001", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "227", "bibliographicPageStart": "205", "bibliographicVolumeNumber": "50", "bibliographic_titles": [{"bibliographic_title": "Radioisotopes"}]}]}, "item_10004_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "positron emitting radiopharmaceuticals,minimum requrements for positron emitting radiopharmaceuticals in medical institutes,general rules for preparations, general tests,fluorine-18-2-deoxy-2-fluoro-D-glucose,oxygen-15-oxygen,oxygen-15-carbon monoxide,oxygen-15-carbon dioxide,manufacturing environment,manufacturing control organization, quality control organization,environmental monitoring,drug product standard code,manufacturing control standard code,manufacturing hygiene control stndard code,quality control standard code,Good Manufacturing Practice", "subitem_description_type": "Abstract"}]}, "item_10004_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0033-8303", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "小西, 淳二"}], "nameIdentifiers": [{"nameIdentifier": "562479", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "佐治, 英郎"}], "nameIdentifiers": [{"nameIdentifier": "562480", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "井戸, 達雄"}], "nameIdentifiers": [{"nameIdentifier": "562481", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "井上, 修"}], "nameIdentifiers": [{"nameIdentifier": "562482", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "鈴木, 和年"}], "nameIdentifiers": [{"nameIdentifier": "562483", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "田中, 彰"}], "nameIdentifiers": [{"nameIdentifier": "562484", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "前田, 稔"}], "nameIdentifiers": [{"nameIdentifier": "562485", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "安原, 眞人"}], "nameIdentifiers": [{"nameIdentifier": "562486", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "佐治 英郎", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "562487", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "井上 修", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "562488", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "鈴木 和年", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "562489", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "前田 稔", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "562490", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "「サイクロトロン核医学利用専門委員会が成熟技術として認定した放射性薬剤の基準(2001年改定)」に関する解説", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "「サイクロトロン核医学利用専門委員会が成熟技術として認定した放射性薬剤の基準(2001年改定)」に関する解説"}]}, "item_type_id": "10004", "owner": "1", "path": ["7"], "permalink_uri": "https://repo.qst.go.jp/records/54985", "pubdate": {"attribute_name": "公開日", "attribute_value": "2002-04-03"}, "publish_date": "2002-04-03", "publish_status": "0", "recid": "54985", "relation": {}, "relation_version_is_last": true, "title": ["「サイクロトロン核医学利用専門委員会が成熟技術として認定した放射性薬剤の基準(2001年改定)」に関する解説"], "weko_shared_id": -1}
「サイクロトロン核医学利用専門委員会が成熟技術として認定した放射性薬剤の基準(2001年改定)」に関する解説
https://repo.qst.go.jp/records/54985
https://repo.qst.go.jp/records/54985d9b7cd34-3a27-4e2f-a092-7baccc70327d
Item type | 一般雑誌記事 / Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2002-04-03 | |||||
タイトル | ||||||
タイトル | 「サイクロトロン核医学利用専門委員会が成熟技術として認定した放射性薬剤の基準(2001年改定)」に関する解説 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
小西, 淳二
× 小西, 淳二× 佐治, 英郎× 井戸, 達雄× 井上, 修× 鈴木, 和年× 田中, 彰× 前田, 稔× 安原, 眞人× 佐治 英郎× 井上 修× 鈴木 和年× 前田 稔 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | positron emitting radiopharmaceuticals,minimum requrements for positron emitting radiopharmaceuticals in medical institutes,general rules for preparations, general tests,fluorine-18-2-deoxy-2-fluoro-D-glucose,oxygen-15-oxygen,oxygen-15-carbon monoxide,oxygen-15-carbon dioxide,manufacturing environment,manufacturing control organization, quality control organization,environmental monitoring,drug product standard code,manufacturing control standard code,manufacturing hygiene control stndard code,quality control standard code,Good Manufacturing Practice | |||||
書誌情報 |
Radioisotopes 巻 50, p. 205-227, 発行日 2001 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0033-8303 |