WEKO3
アイテム
{"_buckets": {"deposit": "ac396432-fd85-47b7-b824-845fa5ce0667"}, "_deposit": {"created_by": 1, "id": "54954", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "54954"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00054954", "sets": ["2"]}, "author_link": ["561957", "561955", "561954", "561956"], "item_10003_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2019-01", "bibliographicIssueDateType": "Issued"}, "bibliographic_titles": [{"bibliographic_title": "第15回日本加速器学会年会論文集"}]}]}, "item_10003_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "In this research, we have constructed a two-photon interference measurement system to evaluate the bunch length in\nthe storage ring of HiSOR. We will try the two-photon interference experiment of the synchrotron radiation by making\nthe Michelson’s type interferometer with prisms and mirrors. To use photomultiplier tubes for photon counting, a new\nhigh voltage power supply unit is fabricated and calibrated. For the sake of comparison, we also consider the electron\nbunch length measurement by the streak camera. At present, an interferometer is constructed and the alignment with a -\n-Ne laser is performed. As the result of the alignment, we confirm the interference fringes. In the future research, it is\nnecessary to make the two beams into parallel waves that the interference fringes are not observed. Also, since the\nphotomultiplier tubes have to work at the photon counting mode for the synchrotron radiation, it is necessary to construct\na reliable shading system of stray light. After the light shielding system is constructed and the alignment of the two beams\nare completed, we will perform the two-photon interferometry with the synchrotron radiation. ", "subitem_description_type": "Abstract"}]}, "item_10003_relation_17": {"attribute_name": "関連サイト", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "https://www.pasj.jp/web_publish/pasj2018/proceedings/PDF/WEP0/WEP081.pdf"}], "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://www.pasj.jp/web_publish/pasj2018/proceedings/PDF/WEP0/WEP081.pdf", "subitem_relation_type_select": "URI"}}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "野津庄平"}], "nameIdentifiers": [{"nameIdentifier": "561954", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "松葉俊哉"}], "nameIdentifiers": [{"nameIdentifier": "561955", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "川瀬, 啓悟"}], "nameIdentifiers": [{"nameIdentifier": "561956", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "川瀬 啓悟", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "561957", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference paper", "resourceuri": "http://purl.org/coar/resource_type/c_5794"}]}, "item_title": "電子バンチ長評価を目指した放射光による2光子干渉計測システムの構築", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "電子バンチ長評価を目指した放射光による2光子干渉計測システムの構築"}]}, "item_type_id": "10003", "owner": "1", "path": ["2"], "permalink_uri": "https://repo.qst.go.jp/records/54954", "pubdate": {"attribute_name": "公開日", "attribute_value": "2019-01-10"}, "publish_date": "2019-01-10", "publish_status": "0", "recid": "54954", "relation": {}, "relation_version_is_last": true, "title": ["電子バンチ長評価を目指した放射光による2光子干渉計測システムの構築"], "weko_shared_id": -1}
電子バンチ長評価を目指した放射光による2光子干渉計測システムの構築
https://repo.qst.go.jp/records/54954
https://repo.qst.go.jp/records/5495435c1eb89-0f2e-4f03-8ef5-c678ed447460
Item type | 会議発表論文 / Conference Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2019-01-10 | |||||
タイトル | ||||||
タイトル | 電子バンチ長評価を目指した放射光による2光子干渉計測システムの構築 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_5794 | |||||
資源タイプ | conference paper | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
野津庄平
× 野津庄平× 松葉俊哉× 川瀬, 啓悟× 川瀬 啓悟 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | In this research, we have constructed a two-photon interference measurement system to evaluate the bunch length in the storage ring of HiSOR. We will try the two-photon interference experiment of the synchrotron radiation by making the Michelson’s type interferometer with prisms and mirrors. To use photomultiplier tubes for photon counting, a new high voltage power supply unit is fabricated and calibrated. For the sake of comparison, we also consider the electron bunch length measurement by the streak camera. At present, an interferometer is constructed and the alignment with a - -Ne laser is performed. As the result of the alignment, we confirm the interference fringes. In the future research, it is necessary to make the two beams into parallel waves that the interference fringes are not observed. Also, since the photomultiplier tubes have to work at the photon counting mode for the synchrotron radiation, it is necessary to construct a reliable shading system of stray light. After the light shielding system is constructed and the alignment of the two beams are completed, we will perform the two-photon interferometry with the synchrotron radiation. |
|||||
書誌情報 |
第15回日本加速器学会年会論文集 発行日 2019-01 |
|||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://www.pasj.jp/web_publish/pasj2018/proceedings/PDF/WEP0/WEP081.pdf | |||||
関連名称 | https://www.pasj.jp/web_publish/pasj2018/proceedings/PDF/WEP0/WEP081.pdf |