WEKO3
アイテム
{"_buckets": {"deposit": "8fb1b0c3-7970-41ba-95c8-94b799799615"}, "_deposit": {"created_by": 1, "id": "54796", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "54796"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00054796", "sets": ["2"]}, "author_link": ["560185", "560186"], "item_10003_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2016-09", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "1660219-10", "bibliographicPageStart": "1660219-1", "bibliographicVolumeNumber": "44", "bibliographic_titles": [{"bibliographic_title": "International Journal of Modern Physics: Conference Series"}]}]}, "item_10003_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Since 1994, HIMAC has carried out clinical studies and treatments for more than 9000 cancer patients with carbon-ion beams. During the first decade of the HIMAC study, a single beam-wobbling method, adopted as the HIMAC beam-delivery technique, was improved for treatments of moving tumors and for obtaining more conformal dose distribution. During the second decade, a pencil-beam 3D scanning method has been developed toward an “adaptive cancer treatment” for treatments of both static and moving tumors. A new treatment research facility was constructed with HIMAC in order to verify the developed 3D scanning technology through a clinical study that has been successfully conducted since 2011. As the next stage, a compact heavy-ion rotating gantry with a superconducting technology has been developed for the more accurate and shorter-course treatments. The twenty-year development of the heavy-ion radiotherapy technologies including accelerator technologies with HIMAC is reviewed", "subitem_description_type": "Abstract"}]}, "item_10003_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "World Scientific Publishing Co Pte Ltd "}]}, "item_10003_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1142/S2010194516602192 ", "subitem_relation_type_select": "DOI"}}]}, "item_10003_relation_17": {"attribute_name": "関連サイト", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "http://www.worldscientific.com/doi/abs/10.1142/S2010194516602192"}], "subitem_relation_type_id": {"subitem_relation_type_id_text": "http://www.worldscientific.com/doi/abs/10.1142/S2010194516602192", "subitem_relation_type_select": "URI"}}]}, "item_10003_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": " 2010-1945 ", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Noda, Koji"}], "nameIdentifiers": [{"nameIdentifier": "560185", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "野田 耕司", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "560186", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference paper", "resourceuri": "http://purl.org/coar/resource_type/c_5794"}]}, "item_title": "Development of heavy-ion radiotherapy technology with HIMAC", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Development of heavy-ion radiotherapy technology with HIMAC"}]}, "item_type_id": "10003", "owner": "1", "path": ["2"], "permalink_uri": "https://repo.qst.go.jp/records/54796", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-07-13"}, "publish_date": "2017-07-13", "publish_status": "0", "recid": "54796", "relation": {}, "relation_version_is_last": true, "title": ["Development of heavy-ion radiotherapy technology with HIMAC"], "weko_shared_id": -1}
Development of heavy-ion radiotherapy technology with HIMAC
https://repo.qst.go.jp/records/54796
https://repo.qst.go.jp/records/547966da3f3d6-ea38-4249-b084-a805db406d5d
Item type | 会議発表論文 / Conference Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-07-13 | |||||
タイトル | ||||||
タイトル | Development of heavy-ion radiotherapy technology with HIMAC | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_5794 | |||||
資源タイプ | conference paper | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Noda, Koji
× Noda, Koji× 野田 耕司 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Since 1994, HIMAC has carried out clinical studies and treatments for more than 9000 cancer patients with carbon-ion beams. During the first decade of the HIMAC study, a single beam-wobbling method, adopted as the HIMAC beam-delivery technique, was improved for treatments of moving tumors and for obtaining more conformal dose distribution. During the second decade, a pencil-beam 3D scanning method has been developed toward an “adaptive cancer treatment” for treatments of both static and moving tumors. A new treatment research facility was constructed with HIMAC in order to verify the developed 3D scanning technology through a clinical study that has been successfully conducted since 2011. As the next stage, a compact heavy-ion rotating gantry with a superconducting technology has been developed for the more accurate and shorter-course treatments. The twenty-year development of the heavy-ion radiotherapy technologies including accelerator technologies with HIMAC is reviewed | |||||
書誌情報 |
International Journal of Modern Physics: Conference Series 巻 44, p. 1660219-1-1660219-10, 発行日 2016-09 |
|||||
出版者 | ||||||
出版者 | World Scientific Publishing Co Pte Ltd | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 2010-1945 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1142/S2010194516602192 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | http://www.worldscientific.com/doi/abs/10.1142/S2010194516602192 | |||||
関連名称 | http://www.worldscientific.com/doi/abs/10.1142/S2010194516602192 |