{"_buckets": {"deposit": "4a5e6b8f-f084-4dc0-a863-cee449de6f03"}, "_deposit": {"created_by": 1, "id": "54679", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "54679"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00054679", "sets": ["2"]}, "author_link": ["558800", "558802", "558806", "558804", "558810", "558811", "558801", "558805", "558807", "558809", "558803", "558808"], "item_10003_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2016-10", "bibliographicIssueDateType": "Issued"}, "bibliographic_titles": [{"bibliographic_title": "IEEE2015 Conference Record"}]}]}, "item_10003_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The lightweight, high sensitivity and low-price camera to image Cs-137 contamination in environment has been developed. These three merits have not been realized by recent gamma cameras and Compton cameras. The camera images Cs-137 distribution by detecting the characteristic X-rays from it instead of gamma-rays. We have investigated the performance of the characteristic X-ray camera (CXRC) in detail and the specification is summarized. ", "subitem_description_type": "Abstract"}]}, "item_10003_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1109/NSSMIC.2015.7581963", "subitem_relation_type_select": "DOI"}}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Kobayashi, Shingo"}], "nameIdentifiers": [{"nameIdentifier": "558800", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Shinomiya, Takayuki"}], "nameIdentifiers": [{"nameIdentifier": "558801", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Goto, Yuichi"}], "nameIdentifiers": [{"nameIdentifier": "558802", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Terakado, Yasuo"}], "nameIdentifiers": [{"nameIdentifier": "558803", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamanishi, Akio"}], "nameIdentifiers": [{"nameIdentifier": "558804", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kitamura, Hisashi"}], "nameIdentifiers": [{"nameIdentifier": "558805", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tanimoto, Kazuo"}], "nameIdentifiers": [{"nameIdentifier": "558806", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Uchihori, Yukio"}], "nameIdentifiers": [{"nameIdentifier": "558807", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小林 進悟", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "558808", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "四野宮 貴幸", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "558809", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "北村 尚", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "558810", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "内堀 幸夫", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "558811", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference paper", "resourceuri": "http://purl.org/coar/resource_type/c_5794"}]}, "item_title": "Performance of a Characteristic X-ray Camera to Identify Contamination of Radioactive Cesium", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Performance of a Characteristic X-ray Camera to Identify Contamination of Radioactive Cesium"}]}, "item_type_id": "10003", "owner": "1", "path": ["2"], "permalink_uri": "https://repo.qst.go.jp/records/54679", "pubdate": {"attribute_name": "公開日", "attribute_value": "2016-12-20"}, "publish_date": "2016-12-20", "publish_status": "0", "recid": "54679", "relation": {}, "relation_version_is_last": true, "title": ["Performance of a Characteristic X-ray Camera to Identify Contamination of Radioactive Cesium"], "weko_shared_id": -1}
Performance of a Characteristic X-ray Camera to Identify Contamination of Radioactive Cesium
https://repo.qst.go.jp/records/54679
https://repo.qst.go.jp/records/54679f5eab3ac-26db-462b-95d8-78f3440ac480
Item type | 会議発表論文 / Conference Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2016-12-20 | |||||
タイトル | ||||||
タイトル | Performance of a Characteristic X-ray Camera to Identify Contamination of Radioactive Cesium | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_5794 | |||||
資源タイプ | conference paper | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Kobayashi, Shingo
× Kobayashi, Shingo× Shinomiya, Takayuki× Goto, Yuichi× Terakado, Yasuo× Yamanishi, Akio× Kitamura, Hisashi× Tanimoto, Kazuo× Uchihori, Yukio× 小林 進悟× 四野宮 貴幸× 北村 尚× 内堀 幸夫 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The lightweight, high sensitivity and low-price camera to image Cs-137 contamination in environment has been developed. These three merits have not been realized by recent gamma cameras and Compton cameras. The camera images Cs-137 distribution by detecting the characteristic X-rays from it instead of gamma-rays. We have investigated the performance of the characteristic X-ray camera (CXRC) in detail and the specification is summarized. | |||||
書誌情報 |
IEEE2015 Conference Record 発行日 2016-10 |
|||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1109/NSSMIC.2015.7581963 |