WEKO3
アイテム
{"_buckets": {"deposit": "9ea0b013-4e95-4d35-9cdc-7a8d364c2a6f"}, "_deposit": {"created_by": 1, "id": "54268", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "54268"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00054268", "sets": ["2"]}, "author_link": ["554275", "554278", "554276", "554265", "554260", "554281", "554280", "554268", "554258", "554282", "554255", "554262", "554279", "554261", "554264", "554263", "554272", "554256", "554267", "554271", "554266", "554273", "554274", "554277", "554269", "554270", "554259", "554257"], "item_10003_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2009", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "218", "bibliographicPageEnd": "71", "bibliographicPageStart": "64", "bibliographicVolumeNumber": "NIRS-M", "bibliographic_titles": [{"bibliographic_title": "NIRS-ETOILE Joint Symposium on Carbon Ion Radiotherapy"}]}]}, "item_10003_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Purpose: To evaluate the tolerance for and effectiveness of carbon ion radiotherapy in patients with locally recurrent rectal cancer.\nPatients and Methods: We conducted a phase I/II dose escalation study of carbon ion radiotherapy. One hundred patients with 105 sites of locally recurrent cancer receiving carbon ion radiotherapy were analyzed. Forty-eight relapses originated in the presacral region, 28 in the pelvic sidewalls, 16 in the perineal region and 8 in the colorectal anastomosis. The total dose ranged from 67.2 to 73.6 gray equivalent (GyE) and was administered in 16 fixed fractions over 4 weeks (4.2 to 4.6 GyE/fraction). \nResults: None of 75 patients treated with the highest total dose of 73.6 GyE experienced National Cancer Institute - Common Toxicity Criteria grade 3 to 5 acute reactions. The local control rate in patients treated with 73.6 GyE in the present study was 97% at one year and 92% at 3 years. Dose escalation was then halted at this level. The median survival time in patients treated with 73.6 GyE was 54 months (range, 7 to 65 months), and the 1- and 3-year overall survival rates were 71% at 3 years and 39% at 5 years, respectively.\nConclusion: Carbon ion radiotherapy seems to be a safe and effective modality in the management of locally recurrent rectal cancer, providing good local control and offering a survival advantage without unacceptable morbidity.", "subitem_description_type": "Abstract"}]}, "item_10003_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "National Institute of Radiological Sciences"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Yamada, Shigeru"}], "nameIdentifiers": [{"nameIdentifier": "554255", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yanagi, Takeshi"}], "nameIdentifiers": [{"nameIdentifier": "554256", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yasuda, Shigeo"}], "nameIdentifiers": [{"nameIdentifier": "554257", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Imada, Hiroshi"}], "nameIdentifiers": [{"nameIdentifier": "554258", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Katou, Hirotoshi"}], "nameIdentifiers": [{"nameIdentifier": "554259", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kamada, Tadashi"}], "nameIdentifiers": [{"nameIdentifier": "554260", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tsujii, Hirohiko"}], "nameIdentifiers": [{"nameIdentifier": "554261", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tsuji, Hiroshi"}], "nameIdentifiers": [{"nameIdentifier": "554262", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Baba, Masayuki"}], "nameIdentifiers": [{"nameIdentifier": "554263", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Mizoe, Junetsu"}], "nameIdentifiers": [{"nameIdentifier": "554264", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kishimoto, Riwa"}], "nameIdentifiers": [{"nameIdentifier": "554265", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yoshikawa, Kyosan"}], "nameIdentifiers": [{"nameIdentifier": "554266", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kandatsu, Susumu"}], "nameIdentifiers": [{"nameIdentifier": "554267", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ochiai, Takenori"}], "nameIdentifiers": [{"nameIdentifier": "554268", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山田 滋", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "554269", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "柳 剛", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "554270", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "安田 茂雄", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "554271", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "今田 浩史", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "554272", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "加藤 博敏", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "554273", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "鎌田 正", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "554274", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "辻井 博彦", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "554275", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "辻 比呂志", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "554276", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "馬場 雅行", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "554277", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "溝江 純悦", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "554278", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "岸本 理和", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "554279", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "吉川 京燦", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "554280", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "神立 進", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "554281", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "落合 武徳", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "554282", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference paper", "resourceuri": "http://purl.org/coar/resource_type/c_5794"}]}, "item_title": "Carbon Ion Therapy for Patients with Locally Recurrent Rectal Cancer", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Carbon Ion Therapy for Patients with Locally Recurrent Rectal Cancer"}]}, "item_type_id": "10003", "owner": "1", "path": ["2"], "permalink_uri": "https://repo.qst.go.jp/records/54268", "pubdate": {"attribute_name": "公開日", "attribute_value": "2010-12-14"}, "publish_date": "2010-12-14", "publish_status": "0", "recid": "54268", "relation": {}, "relation_version_is_last": true, "title": ["Carbon Ion Therapy for Patients with Locally Recurrent Rectal Cancer"], "weko_shared_id": -1}
Carbon Ion Therapy for Patients with Locally Recurrent Rectal Cancer
https://repo.qst.go.jp/records/54268
https://repo.qst.go.jp/records/54268d75b5425-ec46-40e5-b871-f6aea52f804e
Item type | 会議発表論文 / Conference Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2010-12-14 | |||||
タイトル | ||||||
タイトル | Carbon Ion Therapy for Patients with Locally Recurrent Rectal Cancer | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_5794 | |||||
資源タイプ | conference paper | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Yamada, Shigeru
× Yamada, Shigeru× Yanagi, Takeshi× Yasuda, Shigeo× Imada, Hiroshi× Katou, Hirotoshi× Kamada, Tadashi× Tsujii, Hirohiko× Tsuji, Hiroshi× Baba, Masayuki× Mizoe, Junetsu× Kishimoto, Riwa× Yoshikawa, Kyosan× Kandatsu, Susumu× Ochiai, Takenori× 山田 滋× 柳 剛× 安田 茂雄× 今田 浩史× 加藤 博敏× 鎌田 正× 辻井 博彦× 辻 比呂志× 馬場 雅行× 溝江 純悦× 岸本 理和× 吉川 京燦× 神立 進× 落合 武徳 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Purpose: To evaluate the tolerance for and effectiveness of carbon ion radiotherapy in patients with locally recurrent rectal cancer. Patients and Methods: We conducted a phase I/II dose escalation study of carbon ion radiotherapy. One hundred patients with 105 sites of locally recurrent cancer receiving carbon ion radiotherapy were analyzed. Forty-eight relapses originated in the presacral region, 28 in the pelvic sidewalls, 16 in the perineal region and 8 in the colorectal anastomosis. The total dose ranged from 67.2 to 73.6 gray equivalent (GyE) and was administered in 16 fixed fractions over 4 weeks (4.2 to 4.6 GyE/fraction). Results: None of 75 patients treated with the highest total dose of 73.6 GyE experienced National Cancer Institute - Common Toxicity Criteria grade 3 to 5 acute reactions. The local control rate in patients treated with 73.6 GyE in the present study was 97% at one year and 92% at 3 years. Dose escalation was then halted at this level. The median survival time in patients treated with 73.6 GyE was 54 months (range, 7 to 65 months), and the 1- and 3-year overall survival rates were 71% at 3 years and 39% at 5 years, respectively. Conclusion: Carbon ion radiotherapy seems to be a safe and effective modality in the management of locally recurrent rectal cancer, providing good local control and offering a survival advantage without unacceptable morbidity. |
|||||
書誌情報 |
NIRS-ETOILE Joint Symposium on Carbon Ion Radiotherapy 巻 NIRS-M, 号 218, p. 64-71, 発行日 2009 |
|||||
出版者 | ||||||
出版者 | National Institute of Radiological Sciences |