WEKO3
アイテム
{"_buckets": {"deposit": "61992a8a-def3-4a61-859d-7520814f3865"}, "_deposit": {"created_by": 1, "id": "53854", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "53854"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00053854", "sets": ["2"]}, "author_link": ["549586", "549592", "549587", "549591", "549590", "549585", "549589", "549588"], "item_10003_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2007-03", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "NIRS-M-201", "bibliographicPageStart": "89", "bibliographicVolumeNumber": "第2回", "bibliographic_titles": [{"bibliographic_title": "技術と安全の報告会報告集"}]}]}, "item_10003_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "第1ガンマ線棟に設置されている60Co照射線源(全放射能111TBq)の線源照射筒内の水吸収線量をファーマ基準電離箱で測定し、中心軸の線量分布は0.2mlのファーマ電離箱で測定した。照射筒内の半径方向の線量分布は、ラジオクロミックフイルムの光学濃度分布から算定した。\nガンマ線照射装置の2006年11月1日の基準点における1分間当たりの線量Drは27.92Gyであり、シャッタの開閉による線量Dsは5.272Gyであった。半径方向の線量は中心軸の値を1.00とすれば、半径1cm以内では1%以内の平坦であり、2cmでは3%、3cmでは8%、4cmでは16%それぞれ線量が上昇する。\n水吸収線量の評価は標準測定法01、標準測定法86、ICRUの3方法により算定し、比較検討した。その結果全ては1%以内で一致した。イオン再結合損失による電離電荷への補正係数は、理論と実験から求めたが連続放射線であるため値は小さい。マウス程度の照射体であれば基準点において±2%以内で均一に照射可能であることが判明した。", "subitem_description_type": "Abstract"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "平岡, 武"}], "nameIdentifiers": [{"nameIdentifier": "549585", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "三井, 大輔"}], "nameIdentifiers": [{"nameIdentifier": "549586", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "萩原, 拓也"}], "nameIdentifiers": [{"nameIdentifier": "549587", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "濱野, 毅"}], "nameIdentifiers": [{"nameIdentifier": "549588", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "平岡 武", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "549589", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "三井 大輔", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "549590", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "萩原 拓也", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "549591", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "濱野 毅", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "549592", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference paper", "resourceuri": "http://purl.org/coar/resource_type/c_5794"}]}, "item_title": "第1ガンマ線棟Co-60照射装置(111TBq)の線量測定", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "第1ガンマ線棟Co-60照射装置(111TBq)の線量測定"}]}, "item_type_id": "10003", "owner": "1", "path": ["2"], "permalink_uri": "https://repo.qst.go.jp/records/53854", "pubdate": {"attribute_name": "公開日", "attribute_value": "2007-05-15"}, "publish_date": "2007-05-15", "publish_status": "0", "recid": "53854", "relation": {}, "relation_version_is_last": true, "title": ["第1ガンマ線棟Co-60照射装置(111TBq)の線量測定"], "weko_shared_id": -1}
第1ガンマ線棟Co-60照射装置(111TBq)の線量測定
https://repo.qst.go.jp/records/53854
https://repo.qst.go.jp/records/538541ff7dc2a-0f49-4ccd-b039-7d30099719eb
Item type | 会議発表論文 / Conference Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2007-05-15 | |||||
タイトル | ||||||
タイトル | 第1ガンマ線棟Co-60照射装置(111TBq)の線量測定 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_5794 | |||||
資源タイプ | conference paper | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
平岡, 武
× 平岡, 武× 三井, 大輔× 萩原, 拓也× 濱野, 毅× 平岡 武× 三井 大輔× 萩原 拓也× 濱野 毅 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 第1ガンマ線棟に設置されている60Co照射線源(全放射能111TBq)の線源照射筒内の水吸収線量をファーマ基準電離箱で測定し、中心軸の線量分布は0.2mlのファーマ電離箱で測定した。照射筒内の半径方向の線量分布は、ラジオクロミックフイルムの光学濃度分布から算定した。 ガンマ線照射装置の2006年11月1日の基準点における1分間当たりの線量Drは27.92Gyであり、シャッタの開閉による線量Dsは5.272Gyであった。半径方向の線量は中心軸の値を1.00とすれば、半径1cm以内では1%以内の平坦であり、2cmでは3%、3cmでは8%、4cmでは16%それぞれ線量が上昇する。 水吸収線量の評価は標準測定法01、標準測定法86、ICRUの3方法により算定し、比較検討した。その結果全ては1%以内で一致した。イオン再結合損失による電離電荷への補正係数は、理論と実験から求めたが連続放射線であるため値は小さい。マウス程度の照射体であれば基準点において±2%以内で均一に照射可能であることが判明した。 |
|||||
書誌情報 |
技術と安全の報告会報告集 巻 第2回, 号 NIRS-M-201, p. 89, 発行日 2007-03 |