{"_buckets": {"deposit": "8aa11914-dec7-4ff4-8eaa-2eaa283eef7b"}, "_deposit": {"created_by": 1, "id": "53853", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "53853"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00053853", "sets": ["2"]}, "author_link": ["549584", "549583", "549580", "549581", "549579", "549582"], "item_10003_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2007-03", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "NIRS-M-201", "bibliographicPageStart": "77", "bibliographicVolumeNumber": "第2回", "bibliographic_titles": [{"bibliographic_title": "技術と安全の報告会報告集"}]}]}, "item_10003_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "共同実験機器(以下「共実機器」)は、多種多様な機器がある。それら機器の管理を日々行っているが、今回はその中で細胞分取装置(日本BD社製FACSAria)のメンテナンスについて紹介する。\nFACSAriaは、フローサイトメトリと呼ばれる機器の一種であり、細胞等の分取(ソーティング)が行える機器である。この機器は高性能である反面、利用者が行う使用後の処置及び1週間毎に行う保守が精度の良い測定を行う為には欠かせない。その保守方法及び精度管理について紹介を行いたい。", "subitem_description_type": "Abstract"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "前田, 武"}], "nameIdentifiers": [{"nameIdentifier": "549579", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "高野, 裕之"}], "nameIdentifiers": [{"nameIdentifier": "549580", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小西, 輝昭"}], "nameIdentifiers": [{"nameIdentifier": "549581", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "前田 武", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "549582", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "高野 裕之", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "549583", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小西 輝昭", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "549584", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference paper", "resourceuri": "http://purl.org/coar/resource_type/c_5794"}]}, "item_title": "共実機器のメンテナンス", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "共実機器のメンテナンス"}]}, "item_type_id": "10003", "owner": "1", "path": ["2"], "permalink_uri": "https://repo.qst.go.jp/records/53853", "pubdate": {"attribute_name": "公開日", "attribute_value": "2007-05-15"}, "publish_date": "2007-05-15", "publish_status": "0", "recid": "53853", "relation": {}, "relation_version_is_last": true, "title": ["共実機器のメンテナンス"], "weko_shared_id": -1}
共実機器のメンテナンス
https://repo.qst.go.jp/records/53853
https://repo.qst.go.jp/records/5385324ed975f-a036-4a05-bcec-50b0dd11c415
Item type | 会議発表論文 / Conference Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2007-05-15 | |||||
タイトル | ||||||
タイトル | 共実機器のメンテナンス | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_5794 | |||||
資源タイプ | conference paper | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
前田, 武
× 前田, 武× 高野, 裕之× 小西, 輝昭× 前田 武× 高野 裕之× 小西 輝昭 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 共同実験機器(以下「共実機器」)は、多種多様な機器がある。それら機器の管理を日々行っているが、今回はその中で細胞分取装置(日本BD社製FACSAria)のメンテナンスについて紹介する。 FACSAriaは、フローサイトメトリと呼ばれる機器の一種であり、細胞等の分取(ソーティング)が行える機器である。この機器は高性能である反面、利用者が行う使用後の処置及び1週間毎に行う保守が精度の良い測定を行う為には欠かせない。その保守方法及び精度管理について紹介を行いたい。 |
|||||
書誌情報 |
技術と安全の報告会報告集 巻 第2回, 号 NIRS-M-201, p. 77, 発行日 2007-03 |