WEKO3
アイテム
{"_buckets": {"deposit": "6c9cfc0b-ea53-4fc8-bca2-39b019250351"}, "_deposit": {"created_by": 1, "id": "53786", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "53786"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00053786", "sets": ["2"]}, "author_link": ["548930", "548933", "548931", "548929", "548935", "548934", "548936", "548928", "548927", "548937", "548932"], "item_10003_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2006-08", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "689", "bibliographicPageStart": "687", "bibliographic_titles": [{"bibliographic_title": "日本加速器学会年会・リニアック技術研究会"}]}]}, "item_10003_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "S-LSR is a compact ion storage and cooler ring for R\u0026D of the accelerator for the medical treatment. The vacuum system for S-LSR has been operated from September 2005. The study of the vacuum and the beam lifetime for the proton beam and Mg beam are presented. The design vacuum pressure in S-LSR is 3x10-9 Pa. But the measured\nvacuum pressure is about 7x10-9 Pa because a vacuum leak trouble had happened while lowering the temperature of the baking. The lifetime of 7MeV proton and 35keV Mg+ beam are measured about 55000sec and 13sec in the present status. They are almost consistent with the calculation.", "subitem_description_type": "Abstract"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "頓宮, 拓"}], "nameIdentifiers": [{"nameIdentifier": "548927", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "白井, 敏之"}], "nameIdentifiers": [{"nameIdentifier": "548928", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "野田, 章"}], "nameIdentifiers": [{"nameIdentifier": "548929", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "田辺, 幹夫"}], "nameIdentifiers": [{"nameIdentifier": "548930", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "藤本, 慎司"}], "nameIdentifiers": [{"nameIdentifier": "548931", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "野田, 耕司"}], "nameIdentifiers": [{"nameIdentifier": "548932", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "その他"}], "nameIdentifiers": [{"nameIdentifier": "548933", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "白井 敏之", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "548934", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "野田 章", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "548935", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "藤本 慎司", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "548936", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "野田 耕司", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "548937", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference paper", "resourceuri": "http://purl.org/coar/resource_type/c_5794"}]}, "item_title": "VACUUM AND BEAM LIFETIME IN S-LSR", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "VACUUM AND BEAM LIFETIME IN S-LSR"}]}, "item_type_id": "10003", "owner": "1", "path": ["2"], "permalink_uri": "https://repo.qst.go.jp/records/53786", "pubdate": {"attribute_name": "公開日", "attribute_value": "2006-12-27"}, "publish_date": "2006-12-27", "publish_status": "0", "recid": "53786", "relation": {}, "relation_version_is_last": true, "title": ["VACUUM AND BEAM LIFETIME IN S-LSR"], "weko_shared_id": -1}
VACUUM AND BEAM LIFETIME IN S-LSR
https://repo.qst.go.jp/records/53786
https://repo.qst.go.jp/records/53786a58840d7-af47-4963-808c-d66f01b3b58a
Item type | 会議発表論文 / Conference Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2006-12-27 | |||||
タイトル | ||||||
タイトル | VACUUM AND BEAM LIFETIME IN S-LSR | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_5794 | |||||
資源タイプ | conference paper | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
頓宮, 拓
× 頓宮, 拓× 白井, 敏之× 野田, 章× 田辺, 幹夫× 藤本, 慎司× 野田, 耕司× その他× 白井 敏之× 野田 章× 藤本 慎司× 野田 耕司 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | S-LSR is a compact ion storage and cooler ring for R&D of the accelerator for the medical treatment. The vacuum system for S-LSR has been operated from September 2005. The study of the vacuum and the beam lifetime for the proton beam and Mg beam are presented. The design vacuum pressure in S-LSR is 3x10-9 Pa. But the measured vacuum pressure is about 7x10-9 Pa because a vacuum leak trouble had happened while lowering the temperature of the baking. The lifetime of 7MeV proton and 35keV Mg+ beam are measured about 55000sec and 13sec in the present status. They are almost consistent with the calculation. |
|||||
書誌情報 |
日本加速器学会年会・リニアック技術研究会 p. 687-689, 発行日 2006-08 |