{"_buckets": {"deposit": "f41fb373-c0a3-4176-b291-3cb41576f978"}, "_deposit": {"created_by": 1, "id": "53784", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "53784"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00053784", "sets": ["2"]}, "author_link": ["548914", "548911", "548912", "548913", "548915"], "item_10003_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2006-08", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "158", "bibliographicPageStart": "157", "bibliographic_titles": [{"bibliographic_title": "日本加速器学会年会・リニアック技術研究会"}]}]}, "item_10003_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "6MeV/u Argon beam stacking experiment using electron cooling (EC) has been executing in Heavy Ion Medical Accelerator in Chiba (HIMAC), in order to enhance beam quality, intensity and expand application. Beam loss has been observed at certain intensity due to rapid growth of vertical oscillation. Technique of analog feedback-damping (FBD) is introduced for suppressing the vertical oscillation and for increasing storage beam intensity.", "subitem_description_type": "Abstract"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "野田, 耕司"}], "nameIdentifiers": [{"nameIdentifier": "548911", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "鳥飼, 幸太"}], "nameIdentifiers": [{"nameIdentifier": "548912", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "渋谷, 真二"}], "nameIdentifiers": [{"nameIdentifier": "548913", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "野田 耕司", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "548914", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "鳥飼 幸太", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "548915", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference paper", "resourceuri": "http://purl.org/coar/resource_type/c_5794"}]}, "item_title": "INCREASE OF STORAGE BEAM INTENSITY BY VERTICAL FEEDBACK DAMPING IN HIMAC", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "INCREASE OF STORAGE BEAM INTENSITY BY VERTICAL FEEDBACK DAMPING IN HIMAC"}]}, "item_type_id": "10003", "owner": "1", "path": ["2"], "permalink_uri": "https://repo.qst.go.jp/records/53784", "pubdate": {"attribute_name": "公開日", "attribute_value": "2006-12-27"}, "publish_date": "2006-12-27", "publish_status": "0", "recid": "53784", "relation": {}, "relation_version_is_last": true, "title": ["INCREASE OF STORAGE BEAM INTENSITY BY VERTICAL FEEDBACK DAMPING IN HIMAC"], "weko_shared_id": -1}
INCREASE OF STORAGE BEAM INTENSITY BY VERTICAL FEEDBACK DAMPING IN HIMAC
https://repo.qst.go.jp/records/53784
https://repo.qst.go.jp/records/537843ffbd366-0098-48e3-83e1-c682c2d8f2ce
Item type | 会議発表論文 / Conference Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2006-12-27 | |||||
タイトル | ||||||
タイトル | INCREASE OF STORAGE BEAM INTENSITY BY VERTICAL FEEDBACK DAMPING IN HIMAC | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_5794 | |||||
資源タイプ | conference paper | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
野田, 耕司
× 野田, 耕司× 鳥飼, 幸太× 渋谷, 真二× 野田 耕司× 鳥飼 幸太 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 6MeV/u Argon beam stacking experiment using electron cooling (EC) has been executing in Heavy Ion Medical Accelerator in Chiba (HIMAC), in order to enhance beam quality, intensity and expand application. Beam loss has been observed at certain intensity due to rapid growth of vertical oscillation. Technique of analog feedback-damping (FBD) is introduced for suppressing the vertical oscillation and for increasing storage beam intensity. | |||||
書誌情報 |
日本加速器学会年会・リニアック技術研究会 p. 157-158, 発行日 2006-08 |