WEKO3
アイテム
{"_buckets": {"deposit": "468678f7-bc74-4ea3-aa31-04eee788aa95"}, "_deposit": {"created_by": 1, "id": "53780", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "53780"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00053780", "sets": ["2"]}, "author_link": ["548859", "548860", "548856", "548862", "548858", "548861", "548857"], "item_10003_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2006-08", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "650", "bibliographicPageStart": "648", "bibliographic_titles": [{"bibliographic_title": "日本加速器学会年会・リニアック技術研究会"}]}]}, "item_10003_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "A new method for slow beam extraction from a synchrotron ring is proposed, based on controlling a quadrupole field with a fast response (FQ), assisted by a transverse RF-field (RF-knockout). This method works as follows: 1) particles of a circulating beam are diffused by RF-knockout to just inside the boundary of a separatrix produced under a resonant condition, 2) exciting the FQ shrinks the separatrix to a certain size, and the particles outside the separatrix can be extracted, 3) the fast Q-field is turned off, and 4) the above process is repeated until all of the circulating beam is completely extracted. This method can extract prescribed particles at required timings quickly and precisely, because it is controlled with only the fast Q-field. A proof-of-principle experiment was carried out at the HIMAC synchrotron. As a result, it was verified that the beam was extracted only with exciting the FQ, but not with turning the RF-knockout on.", "subitem_description_type": "Abstract"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "中西, 哲也"}], "nameIdentifiers": [{"nameIdentifier": "548856", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "古川, 卓司"}], "nameIdentifiers": [{"nameIdentifier": "548857", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "野田, 耕司"}], "nameIdentifiers": [{"nameIdentifier": "548858", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "その他"}], "nameIdentifiers": [{"nameIdentifier": "548859", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "中西 哲也", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "548860", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "古川 卓司", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "548861", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "野田 耕司", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "548862", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference paper", "resourceuri": "http://purl.org/coar/resource_type/c_5794"}]}, "item_title": "SLOW BEAM EXTRACTION METHOD USING A FAST Q-MAGNET ASSISTED BY RFKO", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "SLOW BEAM EXTRACTION METHOD USING A FAST Q-MAGNET ASSISTED BY RFKO"}]}, "item_type_id": "10003", "owner": "1", "path": ["2"], "permalink_uri": "https://repo.qst.go.jp/records/53780", "pubdate": {"attribute_name": "公開日", "attribute_value": "2006-12-27"}, "publish_date": "2006-12-27", "publish_status": "0", "recid": "53780", "relation": {}, "relation_version_is_last": true, "title": ["SLOW BEAM EXTRACTION METHOD USING A FAST Q-MAGNET ASSISTED BY RFKO"], "weko_shared_id": -1}
SLOW BEAM EXTRACTION METHOD USING A FAST Q-MAGNET ASSISTED BY RFKO
https://repo.qst.go.jp/records/53780
https://repo.qst.go.jp/records/5378046f72e6e-01c8-4cef-b011-7e153e5d79e1
Item type | 会議発表論文 / Conference Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2006-12-27 | |||||
タイトル | ||||||
タイトル | SLOW BEAM EXTRACTION METHOD USING A FAST Q-MAGNET ASSISTED BY RFKO | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_5794 | |||||
資源タイプ | conference paper | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
中西, 哲也
× 中西, 哲也× 古川, 卓司× 野田, 耕司× その他× 中西 哲也× 古川 卓司× 野田 耕司 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | A new method for slow beam extraction from a synchrotron ring is proposed, based on controlling a quadrupole field with a fast response (FQ), assisted by a transverse RF-field (RF-knockout). This method works as follows: 1) particles of a circulating beam are diffused by RF-knockout to just inside the boundary of a separatrix produced under a resonant condition, 2) exciting the FQ shrinks the separatrix to a certain size, and the particles outside the separatrix can be extracted, 3) the fast Q-field is turned off, and 4) the above process is repeated until all of the circulating beam is completely extracted. This method can extract prescribed particles at required timings quickly and precisely, because it is controlled with only the fast Q-field. A proof-of-principle experiment was carried out at the HIMAC synchrotron. As a result, it was verified that the beam was extracted only with exciting the FQ, but not with turning the RF-knockout on. | |||||
書誌情報 |
日本加速器学会年会・リニアック技術研究会 p. 648-650, 発行日 2006-08 |