{"_buckets": {"deposit": "083a4581-66cd-473d-bd3d-43059d73a454"}, "_deposit": {"created_by": 1, "id": "53767", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "53767"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00053767", "sets": ["2"]}, "author_link": ["548739", "548738", "548744", "548741", "548740", "548742", "548745", "548737", "548743"], "item_10003_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2006", "bibliographicIssueDateType": "Issued"}, "bibliographicPageStart": "1467", "bibliographicVolumeNumber": "14", "bibliographic_titles": [{"bibliographic_title": "Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition"}]}]}, "item_10003_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Gadolinium (Gd) based dynamic susceptibility contrast (DSC) agents allow brain perfusion NMR images in both animal and human [1,2,3,4]. It is not easy to model the arterial input function (AIF) in small animals because of the small ratio of artery to tissue in a voxel. Hence, cerebral blood flow (CBF) values estimated from DSC images can be inaccurate. As an alternative,the maximum value of the logarithmic signal ratio (maxDELTA R2*) is occasionally used as an indicator of the CBF in the rat brain [3,4]. Toinvestigate the accuracy of CBF indicated by maxDELTA R2* in the ischemic rat brain, a comparison of the CBF values obtained with continuous arterial spin labeling (CASL) and maxDELTA R2* was performed in an ischemic rat model.", "subitem_description_type": "Abstract"}]}, "item_10003_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1524-6965", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Nakamura, Kazuhiro"}], "nameIdentifiers": [{"nameIdentifier": "548737", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Masanobu, Ibaraki"}], "nameIdentifiers": [{"nameIdentifier": "548738", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kershaw, Jeffrey"}], "nameIdentifiers": [{"nameIdentifier": "548739", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kanno, Iwao"}], "nameIdentifiers": [{"nameIdentifier": "548740", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "et.al"}], "nameIdentifiers": [{"nameIdentifier": "548741", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "中村 和浩", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "548742", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "茨木 正信", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "548743", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kershaw Jeffrey", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "548744", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "菅野 巖", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "548745", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference paper", "resourceuri": "http://purl.org/coar/resource_type/c_5794"}]}, "item_title": "Comparison of cerebral blood flow estimates in the ischemic area of rat brain obtained with dynamic susceptibility contrast and continuous arterial spin labeling", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Comparison of cerebral blood flow estimates in the ischemic area of rat brain obtained with dynamic susceptibility contrast and continuous arterial spin labeling"}]}, "item_type_id": "10003", "owner": "1", "path": ["2"], "permalink_uri": "https://repo.qst.go.jp/records/53767", "pubdate": {"attribute_name": "公開日", "attribute_value": "2006-11-28"}, "publish_date": "2006-11-28", "publish_status": "0", "recid": "53767", "relation": {}, "relation_version_is_last": true, "title": ["Comparison of cerebral blood flow estimates in the ischemic area of rat brain obtained with dynamic susceptibility contrast and continuous arterial spin labeling"], "weko_shared_id": -1}
Comparison of cerebral blood flow estimates in the ischemic area of rat brain obtained with dynamic susceptibility contrast and continuous arterial spin labeling
https://repo.qst.go.jp/records/53767
https://repo.qst.go.jp/records/537671a92bc40-49f0-49dc-b8a9-3a7585121d84
Item type | 会議発表論文 / Conference Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2006-11-28 | |||||
タイトル | ||||||
タイトル | Comparison of cerebral blood flow estimates in the ischemic area of rat brain obtained with dynamic susceptibility contrast and continuous arterial spin labeling | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_5794 | |||||
資源タイプ | conference paper | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Nakamura, Kazuhiro
× Nakamura, Kazuhiro× Masanobu, Ibaraki× Kershaw, Jeffrey× Kanno, Iwao× et.al× 中村 和浩× 茨木 正信× Kershaw Jeffrey× 菅野 巖 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Gadolinium (Gd) based dynamic susceptibility contrast (DSC) agents allow brain perfusion NMR images in both animal and human [1,2,3,4]. It is not easy to model the arterial input function (AIF) in small animals because of the small ratio of artery to tissue in a voxel. Hence, cerebral blood flow (CBF) values estimated from DSC images can be inaccurate. As an alternative,the maximum value of the logarithmic signal ratio (maxDELTA R2*) is occasionally used as an indicator of the CBF in the rat brain [3,4]. Toinvestigate the accuracy of CBF indicated by maxDELTA R2* in the ischemic rat brain, a comparison of the CBF values obtained with continuous arterial spin labeling (CASL) and maxDELTA R2* was performed in an ischemic rat model. | |||||
書誌情報 |
Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition 巻 14, p. 1467, 発行日 2006 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1524-6965 |