WEKO3
アイテム
{"_buckets": {"deposit": "b34f480b-74af-4105-ab6a-cd716f88bb7c"}, "_deposit": {"created_by": 1, "id": "53579", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "53579"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00053579", "sets": ["2"]}, "author_link": ["546891", "546895", "546896", "546892", "546897", "546890", "546898", "546893", "546894"], "item_10003_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2005-08", "bibliographicIssueDateType": "Issued"}, "bibliographicPageStart": "000", "bibliographicVolumeNumber": "OG", "bibliographic_titles": [{"bibliographic_title": "Proceedings of International Cosmic Ray Conference"}]}]}, "item_10003_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "We are developing the CALET (CALorimetric Electron Telescope) instrument for bserving high energy electrons and gamma rays on ISS. For confirming the CALET capability expected by simulations, we made a scale model of CALET with a size of 2/3 in thickness and had the experimental tests by using beams available in CERN. The beams used are 50GeV, 100GeV electron and 150 GeV proton. The energy resolution is sigma/E = 4.0+-0.1 percent and 2.25+-0.04 percent for 50GeV and 100GeV electrons, respectively. About 97.3 percent of protons can be rejected by shower image with Total Absorption Calorimeter, TASC, while approximately 96.8 percent of electrons were correctly identified. The performance of the scale model was also investigated by Monte Carlo simulation to compare with the results by beam tests. We confirmed good consistency between simulation and the beam test.", "subitem_description_type": "Abstract"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Katayose, Yusaku"}], "nameIdentifiers": [{"nameIdentifier": "546890", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Torii, Syoji"}], "nameIdentifiers": [{"nameIdentifier": "546891", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kitamura, Hisashi"}], "nameIdentifiers": [{"nameIdentifier": "546892", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Uchihori, Yukio"}], "nameIdentifiers": [{"nameIdentifier": "546893", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "et.al"}], "nameIdentifiers": [{"nameIdentifier": "546894", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "片寄 祐作", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "546895", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "鳥居 祥二", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "546896", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "北村 尚", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "546897", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "内堀 幸夫", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "546898", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference paper", "resourceuri": "http://purl.org/coar/resource_type/c_5794"}]}, "item_title": "Performance of the CALET Calorimeter by Accelerator Beam Test", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Performance of the CALET Calorimeter by Accelerator Beam Test"}]}, "item_type_id": "10003", "owner": "1", "path": ["2"], "permalink_uri": "https://repo.qst.go.jp/records/53579", "pubdate": {"attribute_name": "公開日", "attribute_value": "2005-10-06"}, "publish_date": "2005-10-06", "publish_status": "0", "recid": "53579", "relation": {}, "relation_version_is_last": true, "title": ["Performance of the CALET Calorimeter by Accelerator Beam Test"], "weko_shared_id": -1}
Performance of the CALET Calorimeter by Accelerator Beam Test
https://repo.qst.go.jp/records/53579
https://repo.qst.go.jp/records/535799fb40674-66dd-4afd-bbc4-7a2c467d03b6
Item type | 会議発表論文 / Conference Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2005-10-06 | |||||
タイトル | ||||||
タイトル | Performance of the CALET Calorimeter by Accelerator Beam Test | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_5794 | |||||
資源タイプ | conference paper | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Katayose, Yusaku
× Katayose, Yusaku× Torii, Syoji× Kitamura, Hisashi× Uchihori, Yukio× et.al× 片寄 祐作× 鳥居 祥二× 北村 尚× 内堀 幸夫 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | We are developing the CALET (CALorimetric Electron Telescope) instrument for bserving high energy electrons and gamma rays on ISS. For confirming the CALET capability expected by simulations, we made a scale model of CALET with a size of 2/3 in thickness and had the experimental tests by using beams available in CERN. The beams used are 50GeV, 100GeV electron and 150 GeV proton. The energy resolution is sigma/E = 4.0+-0.1 percent and 2.25+-0.04 percent for 50GeV and 100GeV electrons, respectively. About 97.3 percent of protons can be rejected by shower image with Total Absorption Calorimeter, TASC, while approximately 96.8 percent of electrons were correctly identified. The performance of the scale model was also investigated by Monte Carlo simulation to compare with the results by beam tests. We confirmed good consistency between simulation and the beam test. | |||||
書誌情報 |
Proceedings of International Cosmic Ray Conference 巻 OG, p. 000, 発行日 2005-08 |