WEKO3
アイテム
{"_buckets": {"deposit": "f2bfaa0e-5911-44ef-a35b-69c53dce337e"}, "_deposit": {"created_by": 1, "id": "53561", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "53561"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00053561", "sets": ["2"]}, "author_link": ["546679", "546685", "546686", "546689", "546691", "546687", "546692", "546680", "546690", "546693", "546684", "546688", "546694", "546683", "546682", "546681"], "item_10003_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2005-07", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "225", "bibliographicPageStart": "223", "bibliographicVolumeNumber": "2", "bibliographic_titles": [{"bibliographic_title": "日本加速器学会年会・リニアック技術研究会"}]}]}, "item_10003_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "A fast,non-destructive beam-profile monitor was developed using an oxigen gas-sheet target in the HIMAC synchrotron .The size of the gas-sheet target was 85 mm in width and 1.3mm in thickness,of which the density was 1x10^-4^Pa.The base vacuum in the ring was not deteriorated by this gas-sheet target,and was on the order of 10^-8^Pa.In typical cases,carbon ion beams are accelerated from 6 to 290-430MeV/n for cancer therapy,in which the intensity is 2.5x10^8^ particles/bunch.For these beams,two-dimensional beam profiles were successfully measured within the time(~100ns)of the bunch separation.This article describes both the technical and physical aspects of the monitor together with some results.", "subitem_description_type": "Abstract"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "橋本, 義徳"}], "nameIdentifiers": [{"nameIdentifier": "546679", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "藤澤, 高志"}], "nameIdentifiers": [{"nameIdentifier": "546680", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "森本, 輝久"}], "nameIdentifiers": [{"nameIdentifier": "546681", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "藤田, 雄三"}], "nameIdentifiers": [{"nameIdentifier": "546682", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "本間, 壽廣"}], "nameIdentifiers": [{"nameIdentifier": "546683", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "武藤, 豪"}], "nameIdentifiers": [{"nameIdentifier": "546684", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "野田, 耕司"}], "nameIdentifiers": [{"nameIdentifier": "546685", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "佐藤, 幸夫"}], "nameIdentifiers": [{"nameIdentifier": "546686", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "上杉, 智教"}], "nameIdentifiers": [{"nameIdentifier": "546687", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山田, 聰"}], "nameIdentifiers": [{"nameIdentifier": "546688", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "藤澤 高志", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "546689", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "本間 壽廣", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "546690", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "野田 耕司", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "546691", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "佐藤 幸夫", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "546692", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "上杉 智教", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "546693", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山田 聰", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "546694", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference paper", "resourceuri": "http://purl.org/coar/resource_type/c_5794"}]}, "item_title": "酸素分子ガスシートを用いたビームプロファイルモニター", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "酸素分子ガスシートを用いたビームプロファイルモニター"}]}, "item_type_id": "10003", "owner": "1", "path": ["2"], "permalink_uri": "https://repo.qst.go.jp/records/53561", "pubdate": {"attribute_name": "公開日", "attribute_value": "2005-08-17"}, "publish_date": "2005-08-17", "publish_status": "0", "recid": "53561", "relation": {}, "relation_version_is_last": true, "title": ["酸素分子ガスシートを用いたビームプロファイルモニター"], "weko_shared_id": -1}
酸素分子ガスシートを用いたビームプロファイルモニター
https://repo.qst.go.jp/records/53561
https://repo.qst.go.jp/records/53561d0254fe4-c26d-4722-a3c8-46bfaec99fc6
Item type | 会議発表論文 / Conference Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2005-08-17 | |||||
タイトル | ||||||
タイトル | 酸素分子ガスシートを用いたビームプロファイルモニター | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_5794 | |||||
資源タイプ | conference paper | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
橋本, 義徳
× 橋本, 義徳× 藤澤, 高志× 森本, 輝久× 藤田, 雄三× 本間, 壽廣× 武藤, 豪× 野田, 耕司× 佐藤, 幸夫× 上杉, 智教× 山田, 聰× 藤澤 高志× 本間 壽廣× 野田 耕司× 佐藤 幸夫× 上杉 智教× 山田 聰 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | A fast,non-destructive beam-profile monitor was developed using an oxigen gas-sheet target in the HIMAC synchrotron .The size of the gas-sheet target was 85 mm in width and 1.3mm in thickness,of which the density was 1x10^-4^Pa.The base vacuum in the ring was not deteriorated by this gas-sheet target,and was on the order of 10^-8^Pa.In typical cases,carbon ion beams are accelerated from 6 to 290-430MeV/n for cancer therapy,in which the intensity is 2.5x10^8^ particles/bunch.For these beams,two-dimensional beam profiles were successfully measured within the time(~100ns)of the bunch separation.This article describes both the technical and physical aspects of the monitor together with some results. | |||||
書誌情報 |
日本加速器学会年会・リニアック技術研究会 巻 2, p. 223-225, 発行日 2005-07 |