{"_buckets": {"deposit": "09a1cc03-25b2-41fe-88b0-d43ce864fabf"}, "_deposit": {"created_by": 1, "id": "52991", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "52991"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00052991", "sets": ["2"]}, "author_link": ["540541", "540542", "540544", "540543"], "item_10003_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2002-09", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "232", "bibliographicPageStart": "231", "bibliographic_titles": [{"bibliographic_title": "Proceedings of The Third Korea-Japan Joint Meeting on Medical Physics and The Second Asia Oceania Congress of Medical Physics"}]}]}, "item_10003_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "We have been developing microvolume LET counter in order to measure the three-dimensional LET distribution of the therapeutic heavy ion radiation volumes in the water phantom. With help of the technique of cathode induced carhge readout, this detector has a rectangular (box-shape) sensitive volume of which size is about 1 mm2 and 2mm (depth).", "subitem_description_type": "Abstract"}]}, "item_10003_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1589-6691", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Hirai, Masaaki"}], "nameIdentifiers": [{"nameIdentifier": "540541", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kanai, Tatsuaki"}], "nameIdentifiers": [{"nameIdentifier": "540542", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "平井 正明", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "540543", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "金井 達明", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "540544", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference paper", "resourceuri": "http://purl.org/coar/resource_type/c_5794"}]}, "item_title": "Development of Microvolume LET Counter for Therapeutic Heavy Ion Beam", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Development of Microvolume LET Counter for Therapeutic Heavy Ion Beam"}]}, "item_type_id": "10003", "owner": "1", "path": ["2"], "permalink_uri": "https://repo.qst.go.jp/records/52991", "pubdate": {"attribute_name": "公開日", "attribute_value": "2003-01-29"}, "publish_date": "2003-01-29", "publish_status": "0", "recid": "52991", "relation": {}, "relation_version_is_last": true, "title": ["Development of Microvolume LET Counter for Therapeutic Heavy Ion Beam"], "weko_shared_id": -1}
Development of Microvolume LET Counter for Therapeutic Heavy Ion Beam
https://repo.qst.go.jp/records/52991
https://repo.qst.go.jp/records/52991683af43e-ce7d-4de5-8542-a6a7ce51eadf
Item type | 会議発表論文 / Conference Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2003-01-29 | |||||
タイトル | ||||||
タイトル | Development of Microvolume LET Counter for Therapeutic Heavy Ion Beam | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_5794 | |||||
資源タイプ | conference paper | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Hirai, Masaaki
× Hirai, Masaaki× Kanai, Tatsuaki× 平井 正明× 金井 達明 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | We have been developing microvolume LET counter in order to measure the three-dimensional LET distribution of the therapeutic heavy ion radiation volumes in the water phantom. With help of the technique of cathode induced carhge readout, this detector has a rectangular (box-shape) sensitive volume of which size is about 1 mm2 and 2mm (depth). | |||||