WEKO3
アイテム
{"_buckets": {"deposit": "f19ef348-4587-440b-a1bb-54ed4ea3bf24"}, "_deposit": {"created_by": 1, "id": "49561", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "49561"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00049561", "sets": ["1"]}, "author_link": ["873110", "873106", "873108", "873109", "873111", "873107"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2019-01", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "060068-6", "bibliographicPageStart": "060068-1", "bibliographicVolumeNumber": "2054", "bibliographic_titles": [{"bibliographic_title": " AIP Conference Proceedings "}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": " We developed a silicon avalanche photodiode (Si-APD) linear-array detector to be used for nuclear resonant scattering experiments using synchrotron X-rays. The detector has a 64-pixel or 128-pixel linear array (pixel size: 100 × 200 m 2 ). E ach xel tch s 1 0 m , and the depletion depth is 10 m he m lt channel scal ng (M S s stem for the detector counted X-ray pulses over 2048 continuous time bins with minimum time resolution of 0.5 ns. The detector system can record a time spectrum of the nuclear radiation simultaneously with an intensity distribution at each pixel. We \ninvestigated its performance using synchrotron X-rays and the 128-pixel linear array exhibited a time resolution of 0.5 ns (full width at half maximum, FWHM) at 14.4 keV. A vacuum feedthrough for the 64-pixel linear array system was \nfabricated to detect low-energy electrons of \u003c10 keV using internal conversion electrons. The feedthrough consists of a fast-transmission flexible flat cable, multi-electrode micro connectors and a build-up printed circuit board. The energy \nspectra of ~6 keV M-photoelectrons emitted from Tm foil were successively measured in vacuum with one pixel from the 64-pixel linear array using the vacuum feedthrough. The time spectrum was also recorded using the electron signal.", "subitem_description_type": "Abstract"}]}, "item_8_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "AIP Publishing"}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1063/1.5084699", "subitem_relation_type_select": "DOI"}}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Kishimoto, Shunji"}], "nameIdentifiers": [{"nameIdentifier": "873106", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "三井, 隆也"}], "nameIdentifiers": [{"nameIdentifier": "873107", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Haruki, Rie"}], "nameIdentifiers": [{"nameIdentifier": "873108", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Shimazaki, Shunichi"}], "nameIdentifiers": [{"nameIdentifier": "873109", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tanaka, Masanobu"}], "nameIdentifiers": [{"nameIdentifier": "873110", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Mitsui, Takaya", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "873111", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "64- and 128-pixel Si-APD linear array X-ray detectors with 0.5 ns time resolution", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "64- and 128-pixel Si-APD linear array X-ray detectors with 0.5 ns time resolution"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/49561", "pubdate": {"attribute_name": "公開日", "attribute_value": "2019-02-06"}, "publish_date": "2019-02-06", "publish_status": "0", "recid": "49561", "relation": {}, "relation_version_is_last": true, "title": ["64- and 128-pixel Si-APD linear array X-ray detectors with 0.5 ns time resolution"], "weko_shared_id": -1}
64- and 128-pixel Si-APD linear array X-ray detectors with 0.5 ns time resolution
https://repo.qst.go.jp/records/49561
https://repo.qst.go.jp/records/49561898cf40a-c451-4f55-aa24-5b1099dea887
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2019-02-06 | |||||
タイトル | ||||||
タイトル | 64- and 128-pixel Si-APD linear array X-ray detectors with 0.5 ns time resolution | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Kishimoto, Shunji
× Kishimoto, Shunji× 三井, 隆也× Haruki, Rie× Shimazaki, Shunichi× Tanaka, Masanobu× Mitsui, Takaya |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | We developed a silicon avalanche photodiode (Si-APD) linear-array detector to be used for nuclear resonant scattering experiments using synchrotron X-rays. The detector has a 64-pixel or 128-pixel linear array (pixel size: 100 × 200 m 2 ). E ach xel tch s 1 0 m , and the depletion depth is 10 m he m lt channel scal ng (M S s stem for the detector counted X-ray pulses over 2048 continuous time bins with minimum time resolution of 0.5 ns. The detector system can record a time spectrum of the nuclear radiation simultaneously with an intensity distribution at each pixel. We investigated its performance using synchrotron X-rays and the 128-pixel linear array exhibited a time resolution of 0.5 ns (full width at half maximum, FWHM) at 14.4 keV. A vacuum feedthrough for the 64-pixel linear array system was fabricated to detect low-energy electrons of <10 keV using internal conversion electrons. The feedthrough consists of a fast-transmission flexible flat cable, multi-electrode micro connectors and a build-up printed circuit board. The energy spectra of ~6 keV M-photoelectrons emitted from Tm foil were successively measured in vacuum with one pixel from the 64-pixel linear array using the vacuum feedthrough. The time spectrum was also recorded using the electron signal. |
|||||
書誌情報 |
AIP Conference Proceedings 巻 2054, p. 060068-1-060068-6, 発行日 2019-01 |
|||||
出版者 | ||||||
出版者 | AIP Publishing | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1063/1.5084699 |