WEKO3
アイテム
{"_buckets": {"deposit": "c3861c18-db51-4858-a8d2-4e7d250bdfff"}, "_deposit": {"created_by": 1, "id": "49370", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "49370"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00049370", "sets": ["1"]}, "author_link": ["498517", "498519", "498518", "498516", "498515", "498513", "498514", "498512"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2018-02", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "150", "bibliographicPageStart": "146", "bibliographicVolumeNumber": "136", "bibliographic_titles": [{"bibliographic_title": "Fusion Eng. Design"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "A water-cooled ceramic breeder blanket has been developed. Heat flux and coolant pressure are applied to the first wall of the blanket in a fusion reactor. A square cooling channel is adopted in the first wall in Quantum and Radiological Science and Technology (QST). This study specifically addressed the relation between the thermal mechanical responses with different cooling channel shapes and the allowable load of the first wall. Thermal mechanical responses of the first wall were evaluated using finite element method (FEM). Based on those results, the allowable loads for the structural integrity of the first wall were assessed in accordance with the requirements of ASME Sec. III NH. Among the failure modes the creep-fatigue damage was the most dominant on the allowable loads of the first wall. The allowable loads were determined by characteristics of the thermal mechanical responses with the cooling channel shape. The major determinants were the surface heat flux and the coolant pressure, respectively, for the circular and the square channels.", "subitem_description_type": "Abstract"}]}, "item_8_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Elsevier"}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1016/j.fusengdes.2018.01.032", "subitem_relation_type_select": "DOI"}}]}, "item_8_relation_17": {"attribute_name": "関連サイト", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "https://doi.org/10.1016/j.fusengdes.2018.01.032"}], "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://doi.org/10.1016/j.fusengdes.2018.01.032", "subitem_relation_type_select": "DOI"}}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "権, 暁星"}], "nameIdentifiers": [{"nameIdentifier": "498512", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "谷川, 尚"}], "nameIdentifiers": [{"nameIdentifier": "498513", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "廣瀬, 貴規"}], "nameIdentifiers": [{"nameIdentifier": "498514", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "河村, 繕範"}], "nameIdentifiers": [{"nameIdentifier": "498515", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "権 暁星", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "498516", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "谷川 尚", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "498517", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "廣瀬 貴規", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "498518", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "河村 繕範", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "498519", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Thermal mechanical characteristics of blanket first walls with different cooling channel shapes", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Thermal mechanical characteristics of blanket first walls with different cooling channel shapes"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/49370", "pubdate": {"attribute_name": "公開日", "attribute_value": "2018-12-27"}, "publish_date": "2018-12-27", "publish_status": "0", "recid": "49370", "relation": {}, "relation_version_is_last": true, "title": ["Thermal mechanical characteristics of blanket first walls with different cooling channel shapes"], "weko_shared_id": -1}
Thermal mechanical characteristics of blanket first walls with different cooling channel shapes
https://repo.qst.go.jp/records/49370
https://repo.qst.go.jp/records/49370dba17761-257b-4c34-b8cf-88530e1a3665
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2018-12-27 | |||||
タイトル | ||||||
タイトル | Thermal mechanical characteristics of blanket first walls with different cooling channel shapes | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
権, 暁星
× 権, 暁星× 谷川, 尚× 廣瀬, 貴規× 河村, 繕範× 権 暁星× 谷川 尚× 廣瀬 貴規× 河村 繕範 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | A water-cooled ceramic breeder blanket has been developed. Heat flux and coolant pressure are applied to the first wall of the blanket in a fusion reactor. A square cooling channel is adopted in the first wall in Quantum and Radiological Science and Technology (QST). This study specifically addressed the relation between the thermal mechanical responses with different cooling channel shapes and the allowable load of the first wall. Thermal mechanical responses of the first wall were evaluated using finite element method (FEM). Based on those results, the allowable loads for the structural integrity of the first wall were assessed in accordance with the requirements of ASME Sec. III NH. Among the failure modes the creep-fatigue damage was the most dominant on the allowable loads of the first wall. The allowable loads were determined by characteristics of the thermal mechanical responses with the cooling channel shape. The major determinants were the surface heat flux and the coolant pressure, respectively, for the circular and the square channels. | |||||
書誌情報 |
Fusion Eng. Design 巻 136, p. 146-150, 発行日 2018-02 |
|||||
出版者 | ||||||
出版者 | Elsevier | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1016/j.fusengdes.2018.01.032 | |||||
関連サイト | ||||||
識別子タイプ | DOI | |||||
関連識別子 | https://doi.org/10.1016/j.fusengdes.2018.01.032 | |||||
関連名称 | https://doi.org/10.1016/j.fusengdes.2018.01.032 |