WEKO3
アイテム
{"_buckets": {"deposit": "821eda0c-2a2e-45ed-9229-33eb530eff47"}, "_deposit": {"created_by": 1, "id": "49346", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "49346"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00049346", "sets": ["1"]}, "author_link": ["758272", "758273", "758271", "758274"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2018-08", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "11", "bibliographicPageStart": "6", "bibliographicVolumeNumber": "119", "bibliographic_titles": [{"bibliographic_title": "Radiation Measurements"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "International Commission on Radiological Protection recommends that aircraft crew and frequent flyers be informed of their individual doses received from cosmic radiation onboard aircrafts. The cosmic radiation dose in aviation is generally assessed by model calculations. In Japan, the code “JISCARD EX” is used since 2007 for management of cosmic radiation exposure of aircraft crew. In the present study, the precision of this code was investigated in regard to neutrons which contribute the most to the effective dose in aviation. Measurements of cosmic neutrons were performed with two moderator-type neutron monitors having different response functions: a conventional-type rem meter (NCN1) and an extended energy-range rem meter (WENDI-II) in four long-haul flights to Singapore, Sydney, Washington, D.C. and London from Japan (Narita or Kansai airport). Through the combined analyses of these measurements, the contribution of high-energy (\u003e 15 MeV) neutron component was estimated. The ambient dose equivalents, H*(10), measured with WENDI-II agreed well with the calculations made by JISCARD EX, while the contribution of the high-energy component obtained as the difference between\nthe measured H*(10) values of two monitors was systematically higher than the model calculations.", "subitem_description_type": "Abstract"}]}, "item_8_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Elsevier B.V."}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1016/j.radmeas.2018.08.016", "subitem_relation_type_select": "DOI"}}]}, "item_8_relation_17": {"attribute_name": "関連サイト", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "https://doi.org/10.1016/j.radmeas.2018.08.016", "subitem_relation_type_select": "DOI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1350-4487", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Yasuda, Hiroshi"}], "nameIdentifiers": [{"nameIdentifier": "758271", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yajima, Kazuaki"}], "nameIdentifiers": [{"nameIdentifier": "758272", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yasuda, Hiroshi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "758273", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yajima, Kazuaki", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "758274", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Verification of cosmic neutron doses in long-haul flights from Japan", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Verification of cosmic neutron doses in long-haul flights from Japan"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/49346", "pubdate": {"attribute_name": "公開日", "attribute_value": "2018-12-20"}, "publish_date": "2018-12-20", "publish_status": "0", "recid": "49346", "relation": {}, "relation_version_is_last": true, "title": ["Verification of cosmic neutron doses in long-haul flights from Japan"], "weko_shared_id": -1}
Verification of cosmic neutron doses in long-haul flights from Japan
https://repo.qst.go.jp/records/49346
https://repo.qst.go.jp/records/49346dfe2c625-a0f7-40a6-ae5e-4ef3342ea96a
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2018-12-20 | |||||
タイトル | ||||||
タイトル | Verification of cosmic neutron doses in long-haul flights from Japan | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Yasuda, Hiroshi
× Yasuda, Hiroshi× Yajima, Kazuaki× Yasuda, Hiroshi× Yajima, Kazuaki |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | International Commission on Radiological Protection recommends that aircraft crew and frequent flyers be informed of their individual doses received from cosmic radiation onboard aircrafts. The cosmic radiation dose in aviation is generally assessed by model calculations. In Japan, the code “JISCARD EX” is used since 2007 for management of cosmic radiation exposure of aircraft crew. In the present study, the precision of this code was investigated in regard to neutrons which contribute the most to the effective dose in aviation. Measurements of cosmic neutrons were performed with two moderator-type neutron monitors having different response functions: a conventional-type rem meter (NCN1) and an extended energy-range rem meter (WENDI-II) in four long-haul flights to Singapore, Sydney, Washington, D.C. and London from Japan (Narita or Kansai airport). Through the combined analyses of these measurements, the contribution of high-energy (> 15 MeV) neutron component was estimated. The ambient dose equivalents, H*(10), measured with WENDI-II agreed well with the calculations made by JISCARD EX, while the contribution of the high-energy component obtained as the difference between the measured H*(10) values of two monitors was systematically higher than the model calculations. |
|||||
書誌情報 |
Radiation Measurements 巻 119, p. 6-11, 発行日 2018-08 |
|||||
出版者 | ||||||
出版者 | Elsevier B.V. | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1350-4487 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1016/j.radmeas.2018.08.016 | |||||
関連サイト | ||||||
識別子タイプ | DOI | |||||
関連識別子 | https://doi.org/10.1016/j.radmeas.2018.08.016 |