ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Qualitative and Quantitative Assessments of Cardiac Sarcoidosis using 18F-FDG PET

https://repo.qst.go.jp/records/49120
https://repo.qst.go.jp/records/49120
0d704276-3033-4a3d-92e7-fba753b24fac
Item type 学術雑誌論文 / Journal Article(1)
公開日 2018-08-02
タイトル
タイトル Qualitative and Quantitative Assessments of Cardiac Sarcoidosis using 18F-FDG PET
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Manabe, Osamu

× Manabe, Osamu

WEKO 495558

Manabe, Osamu

Search repository
Ohira, Hiroshi

× Ohira, Hiroshi

WEKO 495559

Ohira, Hiroshi

Search repository
Yoshinaga, Keiichiro

× Yoshinaga, Keiichiro

WEKO 495560

Yoshinaga, Keiichiro

Search repository
Naya, Masanao

× Naya, Masanao

WEKO 495561

Naya, Masanao

Search repository
Oyama-Manabe, Noriko

× Oyama-Manabe, Noriko

WEKO 495562

Oyama-Manabe, Noriko

Search repository
Tamaki, Nagara

× Tamaki, Nagara

WEKO 495563

Tamaki, Nagara

Search repository
吉永 恵一郎

× 吉永 恵一郎

WEKO 495564

en 吉永 恵一郎

Search repository
抄録
内容記述タイプ Abstract
内容記述 Sarcoidosis is a multisystem disease pathologically characterized by non-caseating granuloma. Cardiac sarcoidosis (CS) remains an important prognostic factor of sarcoidosis patients. 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography (PET) has been applied as a noninvasive tool not only for CS diagnoses but also for the evaluation of therapeutic effects and prognoses. Visual assessment is a standard method to evaluate whether the 18F-FDG uptake is physiological or active inflammation due to the CS. A semi-quantitative assessment using the standardized uptake value (SUV) is a simple method for achieving a more accurate diagnosis. A volume-based analysis has been proposed as a new marker that can provide information about the improvement or prevention of heart failure and can be used to predict a further clinical event in CS patients. This is a brief review of the objective and quantitative assessments of the magnitude and extent of CS activity with the use of 18F-FDG PET.
書誌情報 Annals of Nuclear Cardiology

巻 3, 号 1, p. 117-120, 発行日 2017-08
出版者
出版者 Shunkosha Co.,Ltd
ISSN
収録物識別子タイプ ISSN
収録物識別子 2189-3926
DOI
識別子タイプ DOI
関連識別子 10.17996/anc.17-00015
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:21:06.715694
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3