WEKO3
アイテム
{"_buckets": {"deposit": "64b9619e-01a8-4a5f-9c78-1440255ef479"}, "_deposit": {"created_by": 1, "id": "48983", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "48983"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00048983", "sets": ["1"]}, "author_link": ["493893", "493894", "493887", "493898", "493895", "493890", "493902", "493900", "493899", "493892", "493896", "493897", "493901", "493891", "493886", "493888", "493889"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2017-03", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "124", "bibliographicPageEnd": "604", "bibliographicPageStart": "600", "bibliographic_titles": [{"bibliographic_title": "Fusion Engineering and Design"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The JT-60SA Tokamak is provided with a cryogenic system with a refrigeration capacity of 9 kW (eqv.) at 4.5 K. Before commissioning and during occasional warm-up periods the total 3.6 t helium inventory (at ∼1.5 Mpa(g)) is stored in six pressure vessels. Each vessel is 22 m long, has a diameter of 4 m, 250 m3 volume, and weighs about 73 t. As the vessels will store pure helium, the tightness and cleanliness require- ments were quite demanding. One of the vessels is also used to receive the cold helium (20 K) from the cryogenic system quench line, following a fast discharge of the superconducting coils. A special 18 m long helium diffuser system and a thermal barrier connector at the quench line flange have been designed and manufactured to avoid local chilling of the vessel wall below the minimum allowed temperature of the material.", "subitem_description_type": "Abstract"}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1016/j.fusengdes.2017.03.034", "subitem_relation_type_select": "DOI"}}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Cardella, Antonino"}], "nameIdentifiers": [{"nameIdentifier": "493886", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Annino, Carmela"}], "nameIdentifiers": [{"nameIdentifier": "493887", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Di, Pietro Enrico"}], "nameIdentifiers": [{"nameIdentifier": "493888", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hajnal, Nandor"}], "nameIdentifiers": [{"nameIdentifier": "493889", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Semeraro, Luigi"}], "nameIdentifiers": [{"nameIdentifier": "493890", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tomarchio, Valerio"}], "nameIdentifiers": [{"nameIdentifier": "493891", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Wanner, Manfred"}], "nameIdentifiers": [{"nameIdentifier": "493892", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Batista, da Cruz Jorge"}], "nameIdentifiers": [{"nameIdentifier": "493893", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Figueiredo, Antonio"}], "nameIdentifiers": [{"nameIdentifier": "493894", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Silva, Joao"}], "nameIdentifiers": [{"nameIdentifier": "493895", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Koide, Yoshihiko"}], "nameIdentifiers": [{"nameIdentifier": "493896", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kizu, Kaname"}], "nameIdentifiers": [{"nameIdentifier": "493897", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Natsume, Kyohei"}], "nameIdentifiers": [{"nameIdentifier": "493898", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Michel, Frederic"}], "nameIdentifiers": [{"nameIdentifier": "493899", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小出 芳彦", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "493900", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "木津 要", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "493901", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "夏目 恭平", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "493902", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Manufacturing and installation of the JT-60SA helium storage vessels for the cryogenic plant", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Manufacturing and installation of the JT-60SA helium storage vessels for the cryogenic plant"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/48983", "pubdate": {"attribute_name": "公開日", "attribute_value": "2018-05-11"}, "publish_date": "2018-05-11", "publish_status": "0", "recid": "48983", "relation": {}, "relation_version_is_last": true, "title": ["Manufacturing and installation of the JT-60SA helium storage vessels for the cryogenic plant"], "weko_shared_id": -1}
Manufacturing and installation of the JT-60SA helium storage vessels for the cryogenic plant
https://repo.qst.go.jp/records/48983
https://repo.qst.go.jp/records/48983e937430b-fe94-4a43-b79b-5261a9d20ca4
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2018-05-11 | |||||
タイトル | ||||||
タイトル | Manufacturing and installation of the JT-60SA helium storage vessels for the cryogenic plant | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Cardella, Antonino
× Cardella, Antonino× Annino, Carmela× Di, Pietro Enrico× Hajnal, Nandor× Semeraro, Luigi× Tomarchio, Valerio× Wanner, Manfred× Batista, da Cruz Jorge× Figueiredo, Antonio× Silva, Joao× Koide, Yoshihiko× Kizu, Kaname× Natsume, Kyohei× Michel, Frederic× 小出 芳彦× 木津 要× 夏目 恭平 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The JT-60SA Tokamak is provided with a cryogenic system with a refrigeration capacity of 9 kW (eqv.) at 4.5 K. Before commissioning and during occasional warm-up periods the total 3.6 t helium inventory (at ∼1.5 Mpa(g)) is stored in six pressure vessels. Each vessel is 22 m long, has a diameter of 4 m, 250 m3 volume, and weighs about 73 t. As the vessels will store pure helium, the tightness and cleanliness require- ments were quite demanding. One of the vessels is also used to receive the cold helium (20 K) from the cryogenic system quench line, following a fast discharge of the superconducting coils. A special 18 m long helium diffuser system and a thermal barrier connector at the quench line flange have been designed and manufactured to avoid local chilling of the vessel wall below the minimum allowed temperature of the material. | |||||
書誌情報 |
Fusion Engineering and Design 号 124, p. 600-604, 発行日 2017-03 |
|||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1016/j.fusengdes.2017.03.034 |