ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Validation of Liquid Lithium Target Stability for an Intense Neutron Source

https://repo.qst.go.jp/records/48981
https://repo.qst.go.jp/records/48981
279ebd7d-98cf-4f23-8b52-dbb6b75363cc
Item type 学術雑誌論文 / Journal Article(1)
公開日 2018-05-11
タイトル
タイトル Validation of Liquid Lithium Target Stability for an Intense Neutron Source
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 近藤, 浩夫

× 近藤, 浩夫

WEKO 493828

近藤, 浩夫

Search repository
Kanemura, Takuji

× Kanemura, Takuji

WEKO 493829

Kanemura, Takuji

Search repository
Furukawa, Tomohiro

× Furukawa, Tomohiro

WEKO 493830

Furukawa, Tomohiro

Search repository
Hirakawa, Yasushi

× Hirakawa, Yasushi

WEKO 493831

Hirakawa, Yasushi

Search repository
Eakai, Eiichi

× Eakai, Eiichi

WEKO 493832

Eakai, Eiichi

Search repository
近藤 浩夫

× 近藤 浩夫

WEKO 493833

en 近藤 浩夫

Search repository
抄録
内容記述タイプ Abstract
内容記述 This paper reports on the validation results for the stability of a liquid lithium (Li) target being intended for use as an intense fusion neutron source such as the International Fusion Materials Irradiation Facility (IFMIF), the Advanced Fusion Neutron Source (A-FNS), and the DEMO Oriented Neutron Source (DONES). The variation in the thickness of a Li target must be suppressed to within ±1 mm inside a deuteron beam footprint to both maintain the integrity of the Li target and guarantee the desired level of the neutron flux. We achieve a stable Li target with an average thickness variation of just 0.17 mm inside the beam footprint under standard IFMIF operating conditions (target speed: 15 m/s, vacuum pressure: 10−3 Pa, and Li temperature: 250 °C). Moreover, the mean and maximum wave amplitudes under such conditions were found to be 0.26 mm and 1.46 mm, respectively, at the beam center; these are small enough to satisfy the operational requirements. Finally, it was determined that the stability of the Li target remained unchanged despite using it for a period of 1,561 h. This finding is regarded as a significant step toward the realization of the IFMIF and the potential use of relevant neutron sources such as A-FNS and DONES.
書誌情報 Nuclear Fusion

巻 57, p. 066008, 発行日 2017-04
DOI
識別子タイプ DOI
関連識別子 10.1088/1741-4326/aa5fbd
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:22:15.985253
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3