The FLUKA Monte Carlo code coupled with the NIRS approach for clinical dose calculations in carbon ion therapy

https://repo.qst.go.jp/records/48895
https://repo.qst.go.jp/records/48895
c0812b07-92c5-4cbf-89f6-2eb303c89340
Item type 学術雑誌論文 / Journal Article(1)
公開日 2018-05-08
タイトル
タイトル The FLUKA Monte Carlo code coupled with the NIRS approach for clinical dose calculations in carbon ion therapy
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Magro, G.

× Magro, G.

WEKO 492602

Magro, G.

Search repository
J., Dahle T.

× J., Dahle T.

WEKO 492603

J., Dahle T.

Search repository
Molinelli, S.

× Molinelli, S.

WEKO 492604

Molinelli, S.

Search repository
Ciocca, M.

× Ciocca, M.

WEKO 492605

Ciocca, M.

Search repository
Fossati, P.

× Fossati, P.

WEKO 492606

Fossati, P.

Search repository
Ferrari, A.

× Ferrari, A.

WEKO 492607

Ferrari, A.

Search repository
稲庭, 拓

× 稲庭, 拓

WEKO 492608

稲庭, 拓

Search repository
Matsufuji, Naruhiro

× Matsufuji, Naruhiro

WEKO 492609

Matsufuji, Naruhiro

Search repository
S., Ytre-Hauge K.

× S., Ytre-Hauge K.

WEKO 492610

S., Ytre-Hauge K.

Search repository
Mairani, A.

× Mairani, A.

WEKO 492611

Mairani, A.

Search repository
稲庭 拓

× 稲庭 拓

WEKO 492612

en 稲庭 拓

Search repository
松藤 成弘

× 松藤 成弘

WEKO 492613

en 松藤 成弘

Search repository
抄録
内容記述タイプ Abstract
内容記述 Particle therapy facilities often require Monte Carlo (MC) simulations to overcome intrinsic limitations of analytical treatment planning systems (TPS) related to the description of the mixed radiation field and beam interaction with tissue inhomogeneities. Some of these uncertainties may affect the computation of effective dose distributions; therefore, particle therapy dedicated MC codes should provide both absorbed and biological doses. Two biophysical models are currently applied clinically in particle therapy: the local effect model (LEM) and the microdosimetric kinetic model (MKM). In this paper, we describe the coupling of the NIRS (National Institute for Radiological Sciences, Japan) clinical dose to the FLUKA MC code. We moved from the implementation of the model itself to its application in clinical cases, according to the NIRS approach, where a scaling factor is introduced to rescale the (carbon-equivalent) biological dose to a clinical dose level. A high level of agreement was found with published data by exploring a range of values for the MKM input parameters, while some differences were registered in forward recalculations of NIRS patient plans, mainly attributable to differences with the analytical TPS dose engine (taken as reference) in describing the mixed radiation field (lateral spread and fragmentation). We presented a tool which is being used at the Italian National Center for Oncological Hadrontherapy to support the comparison study between the NIRS clinical dose level and the LEM dose specification.
書誌情報 Physics in Medicine & Biology

巻 62, 号 9, p. 3814-3827, 発行日 2018-05
出版者
出版者 IOP Publishing
ISSN
収録物識別子タイプ ISSN
収録物識別子 0031-9155
DOI
識別子タイプ DOI
関連識別子 10.1088/1361-6560/aa642b
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:23:08.958987
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3