{"_buckets": {"deposit": "6b21bf58-6e53-4646-aad1-20c90cc23747"}, "_deposit": {"created_by": 1, "id": "48699", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "48699"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00048699", "sets": ["1"]}, "author_link": ["490005", "490007", "490004", "490006"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2017-10", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "84", "bibliographicPageStart": "79", "bibliographicVolumeNumber": "90", "bibliographic_titles": [{"bibliographic_title": "Physics Procedia"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "A several hundred keV class compact proton microbeam system was developed as a prototype of a 1 MeV compact microbeam system to be used in micro-fabrication and micro-analyses. Optimization of an extraction condition was performed to increase demagnification and to achieve a beam diameter of approximately 1 μm. The beam diameter measurement showed that a diameter of 1.8 μm was obtained. This indicates that the compact microbeam system is a feasible alternative to a MeV class conventional large accelerator system.", "subitem_description_type": "Abstract"}]}, "item_8_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Elsevier"}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1016/j.phpro.2017.09.022", "subitem_relation_type_select": "DOI"}}]}, "item_8_relation_17": {"attribute_name": "関連サイト", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "http://www.sciencedirect.com/science/article/pii/S1875389217301815?via%3Dihub"}], "subitem_relation_type_id": {"subitem_relation_type_id_text": "http://www.sciencedirect.com/science/article/pii/S1875389217301815?via%3Dihub", "subitem_relation_type_select": "URI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1875-3892", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "大久保, 猛"}], "nameIdentifiers": [{"nameIdentifier": "490004", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "石井, 保行"}], "nameIdentifiers": [{"nameIdentifier": "490005", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "大久保 猛", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "490006", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "石井 保行", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "490007", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Beam diameter reduction by optimization of an extraction condition in a compact ion microbeam system", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Beam diameter reduction by optimization of an extraction condition in a compact ion microbeam system"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/48699", "pubdate": {"attribute_name": "公開日", "attribute_value": "2018-04-12"}, "publish_date": "2018-04-12", "publish_status": "0", "recid": "48699", "relation": {}, "relation_version_is_last": true, "title": ["Beam diameter reduction by optimization of an extraction condition in a compact ion microbeam system"], "weko_shared_id": -1}
Beam diameter reduction by optimization of an extraction condition in a compact ion microbeam system
https://repo.qst.go.jp/records/48699
https://repo.qst.go.jp/records/48699049f5686-b245-4ad8-bdb1-671dfd5dc99a
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2018-04-12 | |||||
タイトル | ||||||
タイトル | Beam diameter reduction by optimization of an extraction condition in a compact ion microbeam system | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
大久保, 猛
× 大久保, 猛× 石井, 保行× 大久保 猛× 石井 保行 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | A several hundred keV class compact proton microbeam system was developed as a prototype of a 1 MeV compact microbeam system to be used in micro-fabrication and micro-analyses. Optimization of an extraction condition was performed to increase demagnification and to achieve a beam diameter of approximately 1 μm. The beam diameter measurement showed that a diameter of 1.8 μm was obtained. This indicates that the compact microbeam system is a feasible alternative to a MeV class conventional large accelerator system. | |||||
書誌情報 |
Physics Procedia 巻 90, p. 79-84, 発行日 2017-10 |
|||||
出版者 | ||||||
出版者 | Elsevier | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1875-3892 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1016/j.phpro.2017.09.022 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | http://www.sciencedirect.com/science/article/pii/S1875389217301815?via%3Dihub | |||||
関連名称 | http://www.sciencedirect.com/science/article/pii/S1875389217301815?via%3Dihub |