WEKO3
アイテム
{"_buckets": {"deposit": "80177764-30e6-485c-8225-20ace65d7248"}, "_deposit": {"created_by": 1, "id": "48616", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "48616"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00048616", "sets": ["1"]}, "author_link": ["488895", "488893", "488904", "488902", "488900", "488897", "488901", "488899", "488903", "488894", "488896", "488898"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2017-07", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "7", "bibliographicPageEnd": "432", "bibliographicPageStart": "427", "bibliographicVolumeNumber": "45", "bibliographic_titles": [{"bibliographic_title": "レーザー研究"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "We have developed the flash lamp pumped Nd:YAG laser with 2 J, 50 Hz for the laser hammering test that inspects a tunnel lining concrete. A simple and compact laser system that thermal lens effect was compensated by an adjustment of image tube had a high impact resistance and stability. As the result of the outdoor practical-test in 1.5 month, this laser system was shown to be available for a maintenance-free operation.", "subitem_description_type": "Abstract"}]}, "item_8_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "一般社団法人レーザー学会"}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0387-0200", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "岡田, 大"}], "nameIdentifiers": [{"nameIdentifier": "488893", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "長谷川, 登"}], "nameIdentifiers": [{"nameIdentifier": "488894", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "三上, 勝大"}], "nameIdentifiers": [{"nameIdentifier": "488895", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "近藤, 修司"}], "nameIdentifiers": [{"nameIdentifier": "488896", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "錦野, 将元"}], "nameIdentifiers": [{"nameIdentifier": "488897", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "河内, 哲哉"}], "nameIdentifiers": [{"nameIdentifier": "488898", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "岡田 大", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "488899", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "長谷川 登", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "488900", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "三上 勝大", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "488901", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "近藤 修司", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "488902", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "錦野 将元", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "488903", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "河内 哲哉", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "488904", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "トンネル覆工コンクリート検査に向けたレーザー打音検査用小型高出力高繰り返しレーザー装置の開発", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "トンネル覆工コンクリート検査に向けたレーザー打音検査用小型高出力高繰り返しレーザー装置の開発"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/48616", "pubdate": {"attribute_name": "公開日", "attribute_value": "2018-03-22"}, "publish_date": "2018-03-22", "publish_status": "0", "recid": "48616", "relation": {}, "relation_version_is_last": true, "title": ["トンネル覆工コンクリート検査に向けたレーザー打音検査用小型高出力高繰り返しレーザー装置の開発"], "weko_shared_id": -1}
トンネル覆工コンクリート検査に向けたレーザー打音検査用小型高出力高繰り返しレーザー装置の開発
https://repo.qst.go.jp/records/48616
https://repo.qst.go.jp/records/48616c919ab3e-364e-47d1-b287-537ca10e4e04
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2018-03-22 | |||||
タイトル | ||||||
タイトル | トンネル覆工コンクリート検査に向けたレーザー打音検査用小型高出力高繰り返しレーザー装置の開発 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
岡田, 大
× 岡田, 大× 長谷川, 登× 三上, 勝大× 近藤, 修司× 錦野, 将元× 河内, 哲哉× 岡田 大× 長谷川 登× 三上 勝大× 近藤 修司× 錦野 将元× 河内 哲哉 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | We have developed the flash lamp pumped Nd:YAG laser with 2 J, 50 Hz for the laser hammering test that inspects a tunnel lining concrete. A simple and compact laser system that thermal lens effect was compensated by an adjustment of image tube had a high impact resistance and stability. As the result of the outdoor practical-test in 1.5 month, this laser system was shown to be available for a maintenance-free operation. | |||||
書誌情報 |
レーザー研究 巻 45, 号 7, p. 427-432, 発行日 2017-07 |
|||||
出版者 | ||||||
出版者 | 一般社団法人レーザー学会 | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0387-0200 |