WEKO3
アイテム
{"_buckets": {"deposit": "57c410de-be8d-487b-9769-5c3caeb7a986"}, "_deposit": {"created_by": 1, "id": "48512", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "48512"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00048512", "sets": ["1"]}, "author_link": ["487665", "487669", "487667", "487666", "487668"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2018-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1", "bibliographicPageEnd": "e00497-20", "bibliographicPageStart": "e00497-1", "bibliographicVolumeNumber": "4", "bibliographic_titles": [{"bibliographic_title": "Heliyon"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "We studied 95gTc and 96gTc as alternatives to the medical radioisotope 99mTc. 96gTc (95gTc) can be produced by (p, n) reactions on an enriched 96Mo (95Mo) target with a proton beam provided by a compact accelerator such as a medical cyclotron that generate radioisotopes for positron emission tomography (PET). The γ-rays are measured with an electron-tracking Compton camera (ETCC). We calculated the relative intensities of the γ-rays from 95gTc and 96gTc. The calculated γ-ray intensity of a 96gTc (95gTc) nucleus is as high as 63% (70%) of that of a 99mTc nucleus. We also calculated the patient radiation doses of 95gTc and 96gTc, which were larger than that of 99mTc by a factor of 2–3 based on the applied assumptions. A medical PET cyclotron which can provide proton beams with energies of 11–12 MeV and a current of 100 μA can produce 12 GBq (39 GBq) of 96gTc (95gTc) for operation time of 8 h, which can be used for 240 (200) diagnostic scans.", "subitem_description_type": "Abstract"}]}, "item_8_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Elsevier"}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1016/j.heliyon.2017.e00497", "subitem_relation_type_select": "DOI"}}]}, "item_8_relation_17": {"attribute_name": "関連サイト", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "http://www.sciencedirect.com/science/article/pii/S2405844017330700"}], "subitem_relation_type_id": {"subitem_relation_type_id_text": "http://www.sciencedirect.com/science/article/pii/S2405844017330700", "subitem_relation_type_select": "URI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "2405-8440", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Hayakawa, Takehito"}], "nameIdentifiers": [{"nameIdentifier": "487665", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hatsukawa, Yuichi"}], "nameIdentifiers": [{"nameIdentifier": "487666", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tanimori, Toru"}], "nameIdentifiers": [{"nameIdentifier": "487667", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "早川 岳人", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "487668", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "初川 雄一", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "487669", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Proposal of 95gTc and 96gTc as alternatives to medical radioisotope 99mTc", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Proposal of 95gTc and 96gTc as alternatives to medical radioisotope 99mTc"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/48512", "pubdate": {"attribute_name": "公開日", "attribute_value": "2018-02-15"}, "publish_date": "2018-02-15", "publish_status": "0", "recid": "48512", "relation": {}, "relation_version_is_last": true, "title": ["Proposal of 95gTc and 96gTc as alternatives to medical radioisotope 99mTc"], "weko_shared_id": -1}
Proposal of 95gTc and 96gTc as alternatives to medical radioisotope 99mTc
https://repo.qst.go.jp/records/48512
https://repo.qst.go.jp/records/4851217586a7c-938f-4fd3-8033-9f21640e274b
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2018-02-15 | |||||
タイトル | ||||||
タイトル | Proposal of 95gTc and 96gTc as alternatives to medical radioisotope 99mTc | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Hayakawa, Takehito
× Hayakawa, Takehito× Hatsukawa, Yuichi× Tanimori, Toru× 早川 岳人× 初川 雄一 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | We studied 95gTc and 96gTc as alternatives to the medical radioisotope 99mTc. 96gTc (95gTc) can be produced by (p, n) reactions on an enriched 96Mo (95Mo) target with a proton beam provided by a compact accelerator such as a medical cyclotron that generate radioisotopes for positron emission tomography (PET). The γ-rays are measured with an electron-tracking Compton camera (ETCC). We calculated the relative intensities of the γ-rays from 95gTc and 96gTc. The calculated γ-ray intensity of a 96gTc (95gTc) nucleus is as high as 63% (70%) of that of a 99mTc nucleus. We also calculated the patient radiation doses of 95gTc and 96gTc, which were larger than that of 99mTc by a factor of 2–3 based on the applied assumptions. A medical PET cyclotron which can provide proton beams with energies of 11–12 MeV and a current of 100 μA can produce 12 GBq (39 GBq) of 96gTc (95gTc) for operation time of 8 h, which can be used for 240 (200) diagnostic scans. | |||||
書誌情報 |
Heliyon 巻 4, 号 1, p. e00497-1-e00497-20, 発行日 2018-01 |
|||||
出版者 | ||||||
出版者 | Elsevier | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 2405-8440 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1016/j.heliyon.2017.e00497 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | http://www.sciencedirect.com/science/article/pii/S2405844017330700 | |||||
関連名称 | http://www.sciencedirect.com/science/article/pii/S2405844017330700 |