WEKO3
アイテム
{"_buckets": {"deposit": "c8728d21-88db-4029-ba23-b2feb52de0c2"}, "_deposit": {"created_by": 1, "id": "48457", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "48457"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00048457", "sets": ["1"]}, "author_link": ["487193", "487186", "487187", "487191", "487189", "487188", "487195", "487196", "487192", "487197", "487190", "487194"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2017-01", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "105", "bibliographicPageStart": "100", "bibliographicVolumeNumber": "404", "bibliographic_titles": [{"bibliographic_title": "Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "数100μm径のエアロゾル等に付着した化学物質の同定とマイクロメートルレベルの分解能での分布の計測を可能にすることを目的に、イオンマイクロビームの物質照射によるIBIL (ion beam induced luminescence: イオンビーム誘起発光)をフォトンカウンティングレベルの高感度で多波長同時計測と2次元マッピングを実現する技術として、高効率光学格子と32チャンネルアレイの光電子増倍管を用いた高感度波長分散IBIL分析システムを開発した。3MeVのプロトンマイクロビームを標準試料(有機化合物)に照射して発生した可視光を用いてシステムの性能評価を行った結果、有機化合物の分析に十分な波長分解能と、多波長の発光強度を同時に10μmより高い空間分解能でマッピングでき、目標性能を達成した。", "subitem_description_type": "Abstract"}]}, "item_8_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Elsevier"}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1016/j.nimb.2017.01.025", "subitem_relation_type_select": "DOI"}}]}, "item_8_relation_17": {"attribute_name": "関連サイト", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "http://www.sciencedirect.com/science/article/pii/S0168583X17300332"}], "subitem_relation_type_id": {"subitem_relation_type_id_text": "http://www.sciencedirect.com/science/article/pii/S0168583X17300332", "subitem_relation_type_select": "URI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0168-583X", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Kada, Wataru"}], "nameIdentifiers": [{"nameIdentifier": "487186", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kawabata, Shunsuke"}], "nameIdentifiers": [{"nameIdentifier": "487187", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Satoh, Takahiro"}], "nameIdentifiers": [{"nameIdentifier": "487188", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sakai, Makoto"}], "nameIdentifiers": [{"nameIdentifier": "487189", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kumar, Parajuli Raj"}], "nameIdentifiers": [{"nameIdentifier": "487190", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamada, Naoto"}], "nameIdentifiers": [{"nameIdentifier": "487191", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Koka, Masashi"}], "nameIdentifiers": [{"nameIdentifier": "487192", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Miura, Kenta"}], "nameIdentifiers": [{"nameIdentifier": "487193", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hanaizumi, Osamu"}], "nameIdentifiers": [{"nameIdentifier": "487194", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kamiya, Tomihiro"}], "nameIdentifiers": [{"nameIdentifier": "487195", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "佐藤 隆博", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "487196", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山田 尚人", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "487197", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Observation of changes in ion beam induced luminescence spectra from organics during focused microbeam irradiation", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Observation of changes in ion beam induced luminescence spectra from organics during focused microbeam irradiation"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/48457", "pubdate": {"attribute_name": "公開日", "attribute_value": "2018-02-06"}, "publish_date": "2018-02-06", "publish_status": "0", "recid": "48457", "relation": {}, "relation_version_is_last": true, "title": ["Observation of changes in ion beam induced luminescence spectra from organics during focused microbeam irradiation"], "weko_shared_id": -1}
Observation of changes in ion beam induced luminescence spectra from organics during focused microbeam irradiation
https://repo.qst.go.jp/records/48457
https://repo.qst.go.jp/records/48457a3c9110d-a601-42fd-b124-57ca9ed7360a
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2018-02-06 | |||||
タイトル | ||||||
タイトル | Observation of changes in ion beam induced luminescence spectra from organics during focused microbeam irradiation | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Kada, Wataru
× Kada, Wataru× Kawabata, Shunsuke× Satoh, Takahiro× Sakai, Makoto× Kumar, Parajuli Raj× Yamada, Naoto× Koka, Masashi× Miura, Kenta× Hanaizumi, Osamu× Kamiya, Tomihiro× 佐藤 隆博× 山田 尚人 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 数100μm径のエアロゾル等に付着した化学物質の同定とマイクロメートルレベルの分解能での分布の計測を可能にすることを目的に、イオンマイクロビームの物質照射によるIBIL (ion beam induced luminescence: イオンビーム誘起発光)をフォトンカウンティングレベルの高感度で多波長同時計測と2次元マッピングを実現する技術として、高効率光学格子と32チャンネルアレイの光電子増倍管を用いた高感度波長分散IBIL分析システムを開発した。3MeVのプロトンマイクロビームを標準試料(有機化合物)に照射して発生した可視光を用いてシステムの性能評価を行った結果、有機化合物の分析に十分な波長分解能と、多波長の発光強度を同時に10μmより高い空間分解能でマッピングでき、目標性能を達成した。 | |||||
書誌情報 |
Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms 巻 404, p. 100-105, 発行日 2017-01 |
|||||
出版者 | ||||||
出版者 | Elsevier | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0168-583X | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1016/j.nimb.2017.01.025 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | http://www.sciencedirect.com/science/article/pii/S0168583X17300332 | |||||
関連名称 | http://www.sciencedirect.com/science/article/pii/S0168583X17300332 |