ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

細胞核内DNA二本鎖切断部位の蛍光標識によるイオントラックの可視化

https://repo.qst.go.jp/records/48447
https://repo.qst.go.jp/records/48447
bc511f6a-9d30-45e0-8a20-99c8f3cf5144
Item type 学術雑誌論文 / Journal Article(1)
公開日 2018-02-04
タイトル
タイトル 細胞核内DNA二本鎖切断部位の蛍光標識によるイオントラックの可視化
言語
言語 jpn
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 小西, 輝昭

× 小西, 輝昭

WEKO 487066

小西, 輝昭

Search repository
竹安, 明浩

× 竹安, 明浩

WEKO 487067

竹安, 明浩

Search repository
雨宮, 邦招

× 雨宮, 邦招

WEKO 487068

雨宮, 邦招

Search repository
夏目, 敏之

× 夏目, 敏之

WEKO 487069

夏目, 敏之

Search repository
安田, 仲宏

× 安田, 仲宏

WEKO 487070

安田, 仲宏

Search repository
檜枝, 光太郎

× 檜枝, 光太郎

WEKO 487071

檜枝, 光太郎

Search repository
小西 輝昭

× 小西 輝昭

WEKO 487072

en 小西 輝昭

Search repository
竹安 明弘

× 竹安 明弘

WEKO 487073

en 竹安 明弘

Search repository
安田 仲宏

× 安田 仲宏

WEKO 487074

en 安田 仲宏

Search repository
檜枝 光太郎

× 檜枝 光太郎

WEKO 487075

en 檜枝 光太郎

Search repository
抄録
内容記述タイプ Abstract
内容記述 The geometric locations of ion traversals in mammalian cells constitute important information in the study of heavy ion-induced biological effects. We will introduce two methods for detecting heavy ion tracks in a nucleus of mammalian cells. The cells were irradiated with Ar ions to visualize the ions traversals by detecting the 3'-OH termini of DNA, where DSBs were induced, which were labeled with BrdU-triphosphate catalyzed by terminal deoxynucleotidyl transferase (TdT). This method of TUNEL is based on the specific binding of TdT to 3'-OH termini of DNA. Then, immuno-fluoresecent staining was performed against BrdU, and the images of the cells nuclei were acquired by confocal laser microscope. Another method is the contact microscopy technique, which was previously reported by Amemiya et al (2005), which enables to visualize simultaneously the images of cells as a relief on a plastic track detector, CR-39, and the etch pits which indicate the positions of ion traversals. We applied this method with immuno-staining assay against gamma-H2AX, which were used as a DNA double strand breaks (DSBs) marker, to compare geometric position of DSBs with the position of the ion traversals in the cell nuclei.
書誌情報 放射線

巻 33, 号 3, p. 201-210, 発行日 2007-07
ISSN
収録物識別子タイプ ISSN
収録物識別子 0285-3604
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:27:59.727130
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3