WEKO3
アイテム
{"_buckets": {"deposit": "6410b51c-f15a-46c6-9195-d91ea97acbb8"}, "_deposit": {"created_by": 1, "id": "47939", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "47939"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00047939", "sets": ["1"]}, "author_link": ["481279", "481277", "481278", "481281", "481284", "481283", "481282", "481280"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2016-11", "bibliographicIssueDateType": "Issued"}, "bibliographicPageStart": "2405083", "bibliographicVolumeNumber": "11", "bibliographic_titles": [{"bibliographic_title": "Plasma and Fusion Research"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "ITER diagnostic lower ports will be used to exchange divertor cassettes and install diagnostic systems. Invessel components of diagnostic lower port #02 (LP#02) will be mounted on a divertor cassette and a support structure, so-called a diagnostic rack, to be removed and reinstalled collectively. Japan Domestic Agency is responsible for procurements of an integration engineering of LP#02 and a divertor impurity monitor, a main tenant system in LP#02. This paper presents preliminary thermal analyses for two critical components in LP#02, the diagnostic rack and a mirror box on the divertor cassette, which will be exposed to the harsh thermal load from plasma. Realistic fabrication methods for cooling the diagnostic rack and a required cooling path layout of the mirror box on the divertor cassette have been assessed to implement the preliminary design from the viewpoint of thermal analysis.", "subitem_description_type": "Abstract"}]}, "item_8_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "プラズマ・核融合学会"}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1585/pfr.11.2402101", "subitem_relation_type_select": "DOI"}}]}, "item_8_relation_17": {"attribute_name": "関連サイト", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "http://www.jspf.or.jp/PFR/PFR_articles/vol11_content.html"}], "subitem_relation_type_id": {"subitem_relation_type_id_text": "http://www.jspf.or.jp/PFR/PFR_articles/vol11_content.html", "subitem_relation_type_select": "URI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1880-6821", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "丸山, 敏征"}], "nameIdentifiers": [{"nameIdentifier": "481277", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "北澤, 真一"}], "nameIdentifiers": [{"nameIdentifier": "481278", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小川, 宏明"}], "nameIdentifiers": [{"nameIdentifier": "481279", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "伊丹, 潔"}], "nameIdentifiers": [{"nameIdentifier": "481280", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "丸山 敏征", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "481281", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "北澤 真一", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "481282", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小川 宏明", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "481283", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "伊丹 潔", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "481284", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Preliminary Thermal Analysis of Critical Components in ITER Lower Port #02", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Preliminary Thermal Analysis of Critical Components in ITER Lower Port #02"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/47939", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-05-09"}, "publish_date": "2017-05-09", "publish_status": "0", "recid": "47939", "relation": {}, "relation_version_is_last": true, "title": ["Preliminary Thermal Analysis of Critical Components in ITER Lower Port #02"], "weko_shared_id": -1}
Preliminary Thermal Analysis of Critical Components in ITER Lower Port #02
https://repo.qst.go.jp/records/47939
https://repo.qst.go.jp/records/47939b9d467db-b7eb-41b3-bed0-960c7cc74023
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-05-09 | |||||
タイトル | ||||||
タイトル | Preliminary Thermal Analysis of Critical Components in ITER Lower Port #02 | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
丸山, 敏征
× 丸山, 敏征× 北澤, 真一× 小川, 宏明× 伊丹, 潔× 丸山 敏征× 北澤 真一× 小川 宏明× 伊丹 潔 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | ITER diagnostic lower ports will be used to exchange divertor cassettes and install diagnostic systems. Invessel components of diagnostic lower port #02 (LP#02) will be mounted on a divertor cassette and a support structure, so-called a diagnostic rack, to be removed and reinstalled collectively. Japan Domestic Agency is responsible for procurements of an integration engineering of LP#02 and a divertor impurity monitor, a main tenant system in LP#02. This paper presents preliminary thermal analyses for two critical components in LP#02, the diagnostic rack and a mirror box on the divertor cassette, which will be exposed to the harsh thermal load from plasma. Realistic fabrication methods for cooling the diagnostic rack and a required cooling path layout of the mirror box on the divertor cassette have been assessed to implement the preliminary design from the viewpoint of thermal analysis. | |||||
書誌情報 |
Plasma and Fusion Research 巻 11, p. 2405083, 発行日 2016-11 |
|||||
出版者 | ||||||
出版者 | プラズマ・核融合学会 | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1880-6821 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1585/pfr.11.2402101 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | http://www.jspf.or.jp/PFR/PFR_articles/vol11_content.html | |||||
関連名称 | http://www.jspf.or.jp/PFR/PFR_articles/vol11_content.html |