WEKO3
アイテム
{"_buckets": {"deposit": "23cf5966-8951-4cae-a839-e9bf6bae5f76"}, "_deposit": {"created_by": 1, "id": "47613", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "47613"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00047613", "sets": ["1"]}, "author_link": ["773927", "773931", "773926", "773929", "773930", "773924", "773928", "773923", "773925"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2016-09", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "19", "bibliographicPageEnd": "4816", "bibliographicPageStart": "4807", "bibliographicVolumeNumber": "51", "bibliographic_titles": [{"bibliographic_title": "Physics in Medicine and Biology"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "We have developed a simple collimator model to improve the accuracy of penumbra behaviour in pencil-beam dose calculation for proton radiotherapy. In this model, transmission of particles through a three-dimensionally extended opening of a collimator is calculated in conjunction with phase-space distribution of the particles. Comparison of the dose distributions calculated using the new three-dimensional collimator model and the conventional twodimensional model to lateral dose profiles experimentally measured with collimated proton beams showed the superiority of the new model over the conventional one.", "subitem_description_type": "Abstract"}]}, "item_8_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "IOP Publishing"}]}, "item_8_relation_13": {"attribute_name": "PubMed番号", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "16985272", "subitem_relation_type_select": "PMID"}}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1088/0031-9155/51/19/006", "subitem_relation_type_select": "DOI"}}]}, "item_8_relation_17": {"attribute_name": "関連サイト", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "https://doi.org/10.1088/0031-9155/51/19/006", "subitem_relation_type_select": "DOI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0031-9155", "subitem_source_identifier_type": "ISSN"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Kanematsu, Nobuyuki"}], "nameIdentifiers": [{"nameIdentifier": "773923", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Akagi, Takashi"}], "nameIdentifiers": [{"nameIdentifier": "773924", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Takatani, Yasuyuki"}], "nameIdentifiers": [{"nameIdentifier": "773925", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yonai, Shunsuke"}], "nameIdentifiers": [{"nameIdentifier": "773926", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sakamoto, Hidenobu"}], "nameIdentifiers": [{"nameIdentifier": "773927", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamashita, Haruo"}], "nameIdentifiers": [{"nameIdentifier": "773928", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kanematsu, Nobuyuki", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "773929", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Akagi, Takashi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "773930", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yonai, Shunsuke", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "773931", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2019-08-06"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "60f4b8f8ebf7421d3f7d02fd326c46e0.pdf", "filesize": [{"value": "386.3 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 386300.0, "url": {"label": "manuscript.pdf", "url": "https://repo.qst.go.jp/record/47613/files/60f4b8f8ebf7421d3f7d02fd326c46e0.pdf"}, "version_id": "14372883-f06f-44c4-9b73-1d5106e87fec"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Extended collimator model for pencil-beam dose calculation in proton radiotherapy", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Extended collimator model for pencil-beam dose calculation in proton radiotherapy"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/47613", "pubdate": {"attribute_name": "公開日", "attribute_value": "2006-09-08"}, "publish_date": "2006-09-08", "publish_status": "0", "recid": "47613", "relation": {}, "relation_version_is_last": true, "title": ["Extended collimator model for pencil-beam dose calculation in proton radiotherapy"], "weko_shared_id": -1}
Extended collimator model for pencil-beam dose calculation in proton radiotherapy
https://repo.qst.go.jp/records/47613
https://repo.qst.go.jp/records/476133ae2b8d1-357b-447e-a228-bc364da654ae
名前 / ファイル | ライセンス | アクション |
---|---|---|
manuscript.pdf (386.3 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2006-09-08 | |||||
タイトル | ||||||
タイトル | Extended collimator model for pencil-beam dose calculation in proton radiotherapy | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Kanematsu, Nobuyuki
× Kanematsu, Nobuyuki× Akagi, Takashi× Takatani, Yasuyuki× Yonai, Shunsuke× Sakamoto, Hidenobu× Yamashita, Haruo× Kanematsu, Nobuyuki× Akagi, Takashi× Yonai, Shunsuke |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | We have developed a simple collimator model to improve the accuracy of penumbra behaviour in pencil-beam dose calculation for proton radiotherapy. In this model, transmission of particles through a three-dimensionally extended opening of a collimator is calculated in conjunction with phase-space distribution of the particles. Comparison of the dose distributions calculated using the new three-dimensional collimator model and the conventional twodimensional model to lateral dose profiles experimentally measured with collimated proton beams showed the superiority of the new model over the conventional one. | |||||
書誌情報 |
Physics in Medicine and Biology 巻 51, 号 19, p. 4807-4816, 発行日 2016-09 |
|||||
出版者 | ||||||
出版者 | IOP Publishing | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0031-9155 | |||||
PubMed番号 | ||||||
識別子タイプ | PMID | |||||
関連識別子 | 16985272 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1088/0031-9155/51/19/006 | |||||
関連サイト | ||||||
識別子タイプ | DOI | |||||
関連識別子 | https://doi.org/10.1088/0031-9155/51/19/006 |