WEKO3
アイテム
{"_buckets": {"deposit": "e25aa5d0-64b0-4951-b51e-7021a1f669ea"}, "_deposit": {"created_by": 1, "id": "47472", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "47472"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00047472", "sets": ["1"]}, "author_link": ["475587", "475595", "475588", "475591", "475593", "475592", "475590", "475586", "475594", "475589"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2015-02", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "6", "bibliographicPageEnd": "540", "bibliographicPageStart": "536", "bibliographicVolumeNumber": "42", "bibliographic_titles": [{"bibliographic_title": "Nuclear medicine and biology"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "A specific diagnosis for melanoma is strongly desired because malignant melanoma has poor prognosis. In a previous study, although radioiodine-125-labeled 4-hydroxyphenyl-L-cysteine ((125)I-L-PC) was found to have good substrate affinity for tyrosinase enzyme in the melanin metabolic pathway, (123/131)I-L-PC had insufficient substrate affinity for tyrosinase to diagnose melanoma. In this study, we synthesized 4-hydroxyphenylcysteamine (4-PCA) and developed a novel radioiodine-125-labeled 4-hydroxyphenylcysteamine ((125)I-PCA) to increase affinity for the melanin biosynthesis pathway.", "subitem_description_type": "Abstract"}]}, "item_8_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Elsevier"}]}, "item_8_relation_13": {"attribute_name": "PubMed番号", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "25744361", "subitem_relation_type_select": "PMID"}}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1016/j.nucmedbio.2015.02.004", "subitem_relation_type_select": "DOI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0969-8051", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Kobayashi, Masato"}], "nameIdentifiers": [{"nameIdentifier": "475586", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nishii, Ryuichi"}], "nameIdentifiers": [{"nameIdentifier": "475587", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Shikano, Naoto"}], "nameIdentifiers": [{"nameIdentifier": "475588", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "G, Flores Leo"}], "nameIdentifiers": [{"nameIdentifier": "475589", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Mizutani, Asuka"}], "nameIdentifiers": [{"nameIdentifier": "475590", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ogai, Kazuhiro"}], "nameIdentifiers": [{"nameIdentifier": "475591", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sugama, Jyunko"}], "nameIdentifiers": [{"nameIdentifier": "475592", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nagamachi, Shigeki"}], "nameIdentifiers": [{"nameIdentifier": "475593", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kawai, Keiichi"}], "nameIdentifiers": [{"nameIdentifier": "475594", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "西井 龍一", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "475595", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Development of radioiodine-labeled 4-hydroxyphenylcysteamine for specific diagnosis of malignant melanoma.", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Development of radioiodine-labeled 4-hydroxyphenylcysteamine for specific diagnosis of malignant melanoma."}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/47472", "pubdate": {"attribute_name": "公開日", "attribute_value": "2016-08-10"}, "publish_date": "2016-08-10", "publish_status": "0", "recid": "47472", "relation": {}, "relation_version_is_last": true, "title": ["Development of radioiodine-labeled 4-hydroxyphenylcysteamine for specific diagnosis of malignant melanoma."], "weko_shared_id": -1}
Development of radioiodine-labeled 4-hydroxyphenylcysteamine for specific diagnosis of malignant melanoma.
https://repo.qst.go.jp/records/47472
https://repo.qst.go.jp/records/47472c0605045-c698-4cb7-bd37-4b37be64cfbc
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2016-08-10 | |||||
タイトル | ||||||
タイトル | Development of radioiodine-labeled 4-hydroxyphenylcysteamine for specific diagnosis of malignant melanoma. | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Kobayashi, Masato
× Kobayashi, Masato× Nishii, Ryuichi× Shikano, Naoto× G, Flores Leo× Mizutani, Asuka× Ogai, Kazuhiro× Sugama, Jyunko× Nagamachi, Shigeki× Kawai, Keiichi× 西井 龍一 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | A specific diagnosis for melanoma is strongly desired because malignant melanoma has poor prognosis. In a previous study, although radioiodine-125-labeled 4-hydroxyphenyl-L-cysteine ((125)I-L-PC) was found to have good substrate affinity for tyrosinase enzyme in the melanin metabolic pathway, (123/131)I-L-PC had insufficient substrate affinity for tyrosinase to diagnose melanoma. In this study, we synthesized 4-hydroxyphenylcysteamine (4-PCA) and developed a novel radioiodine-125-labeled 4-hydroxyphenylcysteamine ((125)I-PCA) to increase affinity for the melanin biosynthesis pathway. | |||||
書誌情報 |
Nuclear medicine and biology 巻 42, 号 6, p. 536-540, 発行日 2015-02 |
|||||
出版者 | ||||||
出版者 | Elsevier | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0969-8051 | |||||
PubMed番号 | ||||||
識別子タイプ | PMID | |||||
関連識別子 | 25744361 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1016/j.nucmedbio.2015.02.004 |