{"_buckets": {"deposit": "8e5a62f3-8485-4bca-a665-8d3e60835ecb"}, "_deposit": {"created_by": 1, "id": "47429", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "47429"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00047429", "sets": ["1"]}, "author_link": ["475041", "475038", "475046", "475047", "475037", "475045", "475042", "475039", "475043", "475044", "475040"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2016-01", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "72", "bibliographicPageStart": "68", "bibliographicVolumeNumber": "812", "bibliographic_titles": [{"bibliographic_title": "Nuclear Instruments and Methods in Physics Research A"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "In a conventional carbon-ion radiotherapy facility, a carbon-ion beam is typically accelerated up to an optimum energy, slowly extracted from a synchrotron ring by a resonant slow extraction method, and ultimately delivered to a patient through a beam-delivery system. At Japan’s Gunma University, a method employing slow-beam extraction along with beam-acceleration has been adopted. This method slightly alters the extracted-beam’s energy owing to the acceleration component of the process, which subsequently results in a residual-range variation of approximately 2 mm in water-equivalent length. However, this range variation does not disturb a distal dose distribution with broad-beam methods such as the single beam-wobbling method. With the pencil-beam 3D scanning method, however, such a range variation disturbs a distal dose distribution because the variation is comparable to slice thickness. Therefore, for pencil-beam 3D scanning, an energy compensation method for a slow extracted beam is proposed in this paper. This method can compensate for the aforementioned energy variances by controlling net energy losses through a rotatable energy absorber set fixed between the synchrotron exit channel and the isocenter. Experimental results demonstrate that beam energies can be maintained constant, as originally hypothesized. Moreover, energy-absorber positions were found to be significantly enhanced by optimizing beam optics for reducing beam-size growth by implementation of the multiple-scattering effect option.", "subitem_description_type": "Abstract"}]}, "item_8_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "ELSEVIER"}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "doi:10.1016/j.nima.2015.12.044", "subitem_relation_type_select": "DOI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0168-9002", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Fujimoto, Tetsuya"}], "nameIdentifiers": [{"nameIdentifier": "475037", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Souda, Hikaru"}], "nameIdentifiers": [{"nameIdentifier": "475038", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Torikoshi, Masami"}], "nameIdentifiers": [{"nameIdentifier": "475039", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kanai, Tatsuaki"}], "nameIdentifiers": [{"nameIdentifier": "475040", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamada, Satoru"}], "nameIdentifiers": [{"nameIdentifier": "475041", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Noda, Koji"}], "nameIdentifiers": [{"nameIdentifier": "475042", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "想田 光", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "475043", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "取越 正己", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "475044", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "金井 達明", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "475045", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山田 聰", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "475046", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "野田 耕司", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "475047", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Energy compensation of slow extracted beams with RF acceleration", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Energy compensation of slow extracted beams with RF acceleration"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/47429", "pubdate": {"attribute_name": "公開日", "attribute_value": "2016-05-19"}, "publish_date": "2016-05-19", "publish_status": "0", "recid": "47429", "relation": {}, "relation_version_is_last": true, "title": ["Energy compensation of slow extracted beams with RF acceleration"], "weko_shared_id": -1}
Energy compensation of slow extracted beams with RF acceleration
https://repo.qst.go.jp/records/47429
https://repo.qst.go.jp/records/47429b67abc0b-c8ac-4d4e-89ae-6898799d789c
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2016-05-19 | |||||
タイトル | ||||||
タイトル | Energy compensation of slow extracted beams with RF acceleration | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Fujimoto, Tetsuya
× Fujimoto, Tetsuya× Souda, Hikaru× Torikoshi, Masami× Kanai, Tatsuaki× Yamada, Satoru× Noda, Koji× 想田 光× 取越 正己× 金井 達明× 山田 聰× 野田 耕司 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | In a conventional carbon-ion radiotherapy facility, a carbon-ion beam is typically accelerated up to an optimum energy, slowly extracted from a synchrotron ring by a resonant slow extraction method, and ultimately delivered to a patient through a beam-delivery system. At Japan’s Gunma University, a method employing slow-beam extraction along with beam-acceleration has been adopted. This method slightly alters the extracted-beam’s energy owing to the acceleration component of the process, which subsequently results in a residual-range variation of approximately 2 mm in water-equivalent length. However, this range variation does not disturb a distal dose distribution with broad-beam methods such as the single beam-wobbling method. With the pencil-beam 3D scanning method, however, such a range variation disturbs a distal dose distribution because the variation is comparable to slice thickness. Therefore, for pencil-beam 3D scanning, an energy compensation method for a slow extracted beam is proposed in this paper. This method can compensate for the aforementioned energy variances by controlling net energy losses through a rotatable energy absorber set fixed between the synchrotron exit channel and the isocenter. Experimental results demonstrate that beam energies can be maintained constant, as originally hypothesized. Moreover, energy-absorber positions were found to be significantly enhanced by optimizing beam optics for reducing beam-size growth by implementation of the multiple-scattering effect option. | |||||
書誌情報 |
Nuclear Instruments and Methods in Physics Research A 巻 812, p. 68-72, 発行日 2016-01 |
|||||
出版者 | ||||||
出版者 | ELSEVIER | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0168-9002 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | doi:10.1016/j.nima.2015.12.044 |