WEKO3
アイテム
{"_buckets": {"deposit": "c8e8c53a-887d-4baf-a4ba-a2a7942336d6"}, "_deposit": {"created_by": 1, "id": "47262", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "47262"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00047262", "sets": ["1"]}, "author_link": ["472704", "472698", "472701", "472703", "472705", "472699", "472700", "472706", "472697", "472702"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2012-09", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1/2", "bibliographicPageEnd": "39", "bibliographicPageStart": "30", "bibliographicVolumeNumber": "19", "bibliographic_titles": [{"bibliographic_title": "Tissue Engineering. Part A"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The objective of this study was to design and prepare a new contrast agent of magnetic resonance (MR) imaging for the evaluation of therapeutic angiogenesis. Diethylenetriaminepentaacetic acid (DTPA) residue of a chelator was chemically introduced to dextran with a molecular weight of 74,000 (dextran-DTPA). Cyclic peptide containing an arginine-glycine-aspartic acid (RGD) sequence (cyclic RGD) with an inherent affinity for the a(v)B(3) integrin was then introduced to dextran-DTPA (Cyclic RGD-dextran-DTPA). Gd(3+) was added to cyclic RGD-dextran-DTPA to prepare a dextran-based MR contrast agent (Cyclic RGD-dextran-DTPA-Gd). Cyclic RGD-dextran-DTPA-Gd had affinity for cells expressing the a(v)B(3) integrin and showed a higher longitudinal relaxivity compared with DTPA-Gd of an MR contrast agent clinically used. Right femoral, external iliac, and deep femoral and circumflex arteries and veins were surgically ligated to prepare a mouse model of hindlimb ischemia. A laser Doppler analysis and histological evaluation confirmed that hindlimb ischemia healed naturally and was accompanied by angiogenesis, while a(v)B(3) integrin was expressed in the ischemic-angiogenic region without any treatment. Mice at 7 days after vascular ligation were used as an angiogenesis model. When intravenously injected into mice with hindlimb ischemia, cyclic RGD-dextran-DTPA accumulated in the ischemic-angiogenic region and showed the MR ability to detect the ischemic-angiogenic region. It is concluded that cyclic RGD-dextran-DTPA-Gd is a promising material for evaluation of therapeutic angiogenesis.", "subitem_description_type": "Abstract"}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1089/ten.tea.2012.0131", "subitem_relation_type_select": "DOI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1937-3341", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Jo, Jun-ichiro"}], "nameIdentifiers": [{"nameIdentifier": "472697", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nakahara, Teppei"}], "nameIdentifiers": [{"nameIdentifier": "472698", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Aoki, Ichio"}], "nameIdentifiers": [{"nameIdentifier": "472699", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Saga, Tsuneo"}], "nameIdentifiers": [{"nameIdentifier": "472700", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tabata, Yasuhiko"}], "nameIdentifiers": [{"nameIdentifier": "472701", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "et.al"}], "nameIdentifiers": [{"nameIdentifier": "472702", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "城 潤一郎", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "472703", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "中原 鉄平", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "472704", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "青木 伊知男", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "472705", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "佐賀 恒夫", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "472706", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Preparation of polymer-based magnetic resonance imaging contrast agent to visualize therapeutic angiogenesis.", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Preparation of polymer-based magnetic resonance imaging contrast agent to visualize therapeutic angiogenesis."}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/47262", "pubdate": {"attribute_name": "公開日", "attribute_value": "2015-08-19"}, "publish_date": "2015-08-19", "publish_status": "0", "recid": "47262", "relation": {}, "relation_version_is_last": true, "title": ["Preparation of polymer-based magnetic resonance imaging contrast agent to visualize therapeutic angiogenesis."], "weko_shared_id": -1}
Preparation of polymer-based magnetic resonance imaging contrast agent to visualize therapeutic angiogenesis.
https://repo.qst.go.jp/records/47262
https://repo.qst.go.jp/records/47262508f1f80-8d27-4fcd-9f5e-584a6b0d88cf
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2015-08-19 | |||||
タイトル | ||||||
タイトル | Preparation of polymer-based magnetic resonance imaging contrast agent to visualize therapeutic angiogenesis. | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Jo, Jun-ichiro
× Jo, Jun-ichiro× Nakahara, Teppei× Aoki, Ichio× Saga, Tsuneo× Tabata, Yasuhiko× et.al× 城 潤一郎× 中原 鉄平× 青木 伊知男× 佐賀 恒夫 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The objective of this study was to design and prepare a new contrast agent of magnetic resonance (MR) imaging for the evaluation of therapeutic angiogenesis. Diethylenetriaminepentaacetic acid (DTPA) residue of a chelator was chemically introduced to dextran with a molecular weight of 74,000 (dextran-DTPA). Cyclic peptide containing an arginine-glycine-aspartic acid (RGD) sequence (cyclic RGD) with an inherent affinity for the a(v)B(3) integrin was then introduced to dextran-DTPA (Cyclic RGD-dextran-DTPA). Gd(3+) was added to cyclic RGD-dextran-DTPA to prepare a dextran-based MR contrast agent (Cyclic RGD-dextran-DTPA-Gd). Cyclic RGD-dextran-DTPA-Gd had affinity for cells expressing the a(v)B(3) integrin and showed a higher longitudinal relaxivity compared with DTPA-Gd of an MR contrast agent clinically used. Right femoral, external iliac, and deep femoral and circumflex arteries and veins were surgically ligated to prepare a mouse model of hindlimb ischemia. A laser Doppler analysis and histological evaluation confirmed that hindlimb ischemia healed naturally and was accompanied by angiogenesis, while a(v)B(3) integrin was expressed in the ischemic-angiogenic region without any treatment. Mice at 7 days after vascular ligation were used as an angiogenesis model. When intravenously injected into mice with hindlimb ischemia, cyclic RGD-dextran-DTPA accumulated in the ischemic-angiogenic region and showed the MR ability to detect the ischemic-angiogenic region. It is concluded that cyclic RGD-dextran-DTPA-Gd is a promising material for evaluation of therapeutic angiogenesis. | |||||
書誌情報 |
Tissue Engineering. Part A 巻 19, 号 1/2, p. 30-39, 発行日 2012-09 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1937-3341 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1089/ten.tea.2012.0131 |