WEKO3
アイテム
{"_buckets": {"deposit": "bb32f3b0-759e-468b-a5c9-a565500c797e"}, "_deposit": {"created_by": 1, "id": "47181", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "47181"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00047181", "sets": ["1"]}, "author_link": ["471504", "471508", "471499", "471509", "471501", "471497", "471495", "471500", "471506", "471502", "471507", "471498", "471494", "471503", "471505", "471496"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2014-06", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "3", "bibliographicPageEnd": "436", "bibliographicPageStart": "431", "bibliographicVolumeNumber": "111", "bibliographic_titles": [{"bibliographic_title": "Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Pencil beam scanning offers excellent conformity, but is sensitive to organ motion. We conducted a simulation study to validate our rescanning approach in combination with gating in the irradiation of liver tumors.", "subitem_description_type": "Abstract"}]}, "item_8_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Elsevier Scientific Publishers"}]}, "item_8_relation_13": {"attribute_name": "PubMed番号", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "24785510", "subitem_relation_type_select": "PMID"}}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1016/j.radonc.2014.03.009", "subitem_relation_type_select": "DOI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0167-8140", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Mori, Shinichiro"}], "nameIdentifiers": [{"nameIdentifier": "471494", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Zenklusen, Silvan"}], "nameIdentifiers": [{"nameIdentifier": "471495", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Inaniwa, Taku"}], "nameIdentifiers": [{"nameIdentifier": "471496", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Furukawa, Takuji"}], "nameIdentifiers": [{"nameIdentifier": "471497", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Imada, Hiroshi"}], "nameIdentifiers": [{"nameIdentifier": "471498", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Shirai, Toshiyuki"}], "nameIdentifiers": [{"nameIdentifier": "471499", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Noda, Koji"}], "nameIdentifiers": [{"nameIdentifier": "471500", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yasuda, Shigeo"}], "nameIdentifiers": [{"nameIdentifier": "471501", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "森 慎一郎", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "471502", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Zenklusen Silvan Marius", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "471503", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "稲庭 拓", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "471504", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "古川 卓司", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "471505", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "今田 浩史", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "471506", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "白井 敏之", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "471507", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "野田 耕司", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "471508", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "安田 茂雄", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "471509", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Conformity and robustness of gated rescanned carbon ion pencil beam scanning of liver tumors at NIRS.", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Conformity and robustness of gated rescanned carbon ion pencil beam scanning of liver tumors at NIRS."}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/47181", "pubdate": {"attribute_name": "公開日", "attribute_value": "2015-07-23"}, "publish_date": "2015-07-23", "publish_status": "0", "recid": "47181", "relation": {}, "relation_version_is_last": true, "title": ["Conformity and robustness of gated rescanned carbon ion pencil beam scanning of liver tumors at NIRS."], "weko_shared_id": -1}
Conformity and robustness of gated rescanned carbon ion pencil beam scanning of liver tumors at NIRS.
https://repo.qst.go.jp/records/47181
https://repo.qst.go.jp/records/47181e76dec11-b8cb-48bd-ae0d-cfa7bcaa9300
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2015-07-23 | |||||
タイトル | ||||||
タイトル | Conformity and robustness of gated rescanned carbon ion pencil beam scanning of liver tumors at NIRS. | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Mori, Shinichiro
× Mori, Shinichiro× Zenklusen, Silvan× Inaniwa, Taku× Furukawa, Takuji× Imada, Hiroshi× Shirai, Toshiyuki× Noda, Koji× Yasuda, Shigeo× 森 慎一郎× Zenklusen Silvan Marius× 稲庭 拓× 古川 卓司× 今田 浩史× 白井 敏之× 野田 耕司× 安田 茂雄 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Pencil beam scanning offers excellent conformity, but is sensitive to organ motion. We conducted a simulation study to validate our rescanning approach in combination with gating in the irradiation of liver tumors. | |||||
書誌情報 |
Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology 巻 111, 号 3, p. 431-436, 発行日 2014-06 |
|||||
出版者 | ||||||
出版者 | Elsevier Scientific Publishers | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0167-8140 | |||||
PubMed番号 | ||||||
識別子タイプ | PMID | |||||
関連識別子 | 24785510 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1016/j.radonc.2014.03.009 |