{"_buckets": {"deposit": "114d9b9d-480c-4ae0-946c-f8ee7265a5dc"}, "_deposit": {"created_by": 1, "id": "47130", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "47130"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00047130", "sets": ["1"]}, "author_link": ["470949", "470952", "470953", "470956", "470959", "470958", "470951", "470954", "470955", "470957", "470950"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2015-05", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "056103-3", "bibliographicPageStart": "056103-1", "bibliographicVolumeNumber": "86", "bibliographic_titles": [{"bibliographic_title": "Review of Scientific instruments"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "A CR-39 plastic nuclear track detector was used for quality assurance of mixed oxide fuel pellets for next-generation nuclear power plants. Plutonium (Pu) spot sizes and concentrations in the pellets are significant parameters for safe use in the plants. We developed an automatic Pu detection system based on dense α-radiation tracks in the CR-39 detectors. This system would greatly improve image processing time and measurement accuracy, and will be a powerful tool for rapid pellet quality assurance screening.", "subitem_description_type": "Abstract"}]}, "item_8_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "AIP Scitation"}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1063/1.4919904", "subitem_relation_type_select": "DOI"}}]}, "item_8_relation_17": {"attribute_name": "関連サイト", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "http://scitation.aip.org/content/aip/journal/rsi/86/5/10.1063/1.4919904"}], "subitem_relation_type_id": {"subitem_relation_type_id_text": "http://scitation.aip.org/content/aip/journal/rsi/86/5/10.1063/1.4919904", "subitem_relation_type_select": "URI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0034-6748", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "S.Kodaira"}], "nameIdentifiers": [{"nameIdentifier": "470949", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "M.Kurano"}], "nameIdentifiers": [{"nameIdentifier": "470950", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hosogane, T."}], "nameIdentifiers": [{"nameIdentifier": "470951", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ishikawa, F."}], "nameIdentifiers": [{"nameIdentifier": "470952", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kageyama, T."}], "nameIdentifiers": [{"nameIdentifier": "470953", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sato, M."}], "nameIdentifiers": [{"nameIdentifier": "470954", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kayano, M."}], "nameIdentifiers": [{"nameIdentifier": "470955", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yasuda, N."}], "nameIdentifiers": [{"nameIdentifier": "470956", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小平 聡", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "470957", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "蔵野 美恵子", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "470958", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "安田 仲宏", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "470959", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Application of CR-39 plastic nuclear track detectors for quality assurance of mixed oxide fuel pellets", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Application of CR-39 plastic nuclear track detectors for quality assurance of mixed oxide fuel pellets"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/47130", "pubdate": {"attribute_name": "公開日", "attribute_value": "2015-05-11"}, "publish_date": "2015-05-11", "publish_status": "0", "recid": "47130", "relation": {}, "relation_version_is_last": true, "title": ["Application of CR-39 plastic nuclear track detectors for quality assurance of mixed oxide fuel pellets"], "weko_shared_id": -1}
Application of CR-39 plastic nuclear track detectors for quality assurance of mixed oxide fuel pellets
https://repo.qst.go.jp/records/47130
https://repo.qst.go.jp/records/471302094c358-b0fe-457f-9110-6bec8ee84c9b
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2015-05-11 | |||||
タイトル | ||||||
タイトル | Application of CR-39 plastic nuclear track detectors for quality assurance of mixed oxide fuel pellets | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
S.Kodaira
× S.Kodaira× M.Kurano× Hosogane, T.× Ishikawa, F.× Kageyama, T.× Sato, M.× Kayano, M.× Yasuda, N.× 小平 聡× 蔵野 美恵子× 安田 仲宏 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | A CR-39 plastic nuclear track detector was used for quality assurance of mixed oxide fuel pellets for next-generation nuclear power plants. Plutonium (Pu) spot sizes and concentrations in the pellets are significant parameters for safe use in the plants. We developed an automatic Pu detection system based on dense α-radiation tracks in the CR-39 detectors. This system would greatly improve image processing time and measurement accuracy, and will be a powerful tool for rapid pellet quality assurance screening. | |||||
書誌情報 |
Review of Scientific instruments 巻 86, p. 056103-1-056103-3, 発行日 2015-05 |
|||||
出版者 | ||||||
出版者 | AIP Scitation | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0034-6748 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1063/1.4919904 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | http://scitation.aip.org/content/aip/journal/rsi/86/5/10.1063/1.4919904 | |||||
関連名称 | http://scitation.aip.org/content/aip/journal/rsi/86/5/10.1063/1.4919904 |