WEKO3
アイテム
{"_buckets": {"deposit": "224e1e6e-dd2a-4f35-9fb6-0ac1e66acde3"}, "_deposit": {"created_by": 1, "id": "47049", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "47049"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00047049", "sets": ["1"]}, "author_link": ["469814", "469815", "469810", "469817", "469812", "469811", "469808", "469816", "469813", "469809"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2014-11", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1043", "bibliographicPageStart": "20140233", "bibliographicVolumeNumber": "87", "bibliographic_titles": [{"bibliographic_title": "The British journal of radiology"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Treatment planning for charged particle therapy in the thoracic and abdominal regions should take account of range uncertainty due to intrafractional motion. Here, we developed a design tool (4Dtool) for the target volume [field-specific target volume (FTV)], which accounts for this uncertainty using four-dimensional CT (4DCT).", "subitem_description_type": "Abstract"}]}, "item_8_relation_13": {"attribute_name": "PubMed番号", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "25168286", "subitem_relation_type_select": "PMID"}}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1259/bjr.20140233", "subitem_relation_type_select": "DOI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0007-1285", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Mori, S"}], "nameIdentifiers": [{"nameIdentifier": "469808", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Inaniwa, T"}], "nameIdentifiers": [{"nameIdentifier": "469809", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Miki, K"}], "nameIdentifiers": [{"nameIdentifier": "469810", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Shirai, T"}], "nameIdentifiers": [{"nameIdentifier": "469811", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Noda, K"}], "nameIdentifiers": [{"nameIdentifier": "469812", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "森 慎一郎", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "469813", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "稲庭 拓", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "469814", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "三木 健太朗", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "469815", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "白井 敏之", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "469816", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "野田 耕司", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "469817", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Implementation of a target volume design function for intrafractional range variation in a particle beam treatment planning system.", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Implementation of a target volume design function for intrafractional range variation in a particle beam treatment planning system."}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/47049", "pubdate": {"attribute_name": "公開日", "attribute_value": "2015-03-25"}, "publish_date": "2015-03-25", "publish_status": "0", "recid": "47049", "relation": {}, "relation_version_is_last": true, "title": ["Implementation of a target volume design function for intrafractional range variation in a particle beam treatment planning system."], "weko_shared_id": -1}
Implementation of a target volume design function for intrafractional range variation in a particle beam treatment planning system.
https://repo.qst.go.jp/records/47049
https://repo.qst.go.jp/records/47049ae9a3d9f-d3a4-4802-87cd-4e5f5d1ec2eb
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2015-03-25 | |||||
タイトル | ||||||
タイトル | Implementation of a target volume design function for intrafractional range variation in a particle beam treatment planning system. | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Mori, S
× Mori, S× Inaniwa, T× Miki, K× Shirai, T× Noda, K× 森 慎一郎× 稲庭 拓× 三木 健太朗× 白井 敏之× 野田 耕司 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Treatment planning for charged particle therapy in the thoracic and abdominal regions should take account of range uncertainty due to intrafractional motion. Here, we developed a design tool (4Dtool) for the target volume [field-specific target volume (FTV)], which accounts for this uncertainty using four-dimensional CT (4DCT). | |||||
書誌情報 |
The British journal of radiology 巻 87, 号 1043, p. 20140233, 発行日 2014-11 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0007-1285 | |||||
PubMed番号 | ||||||
識別子タイプ | PMID | |||||
関連識別子 | 25168286 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1259/bjr.20140233 |