{"_buckets": {"deposit": "f7efa85c-5470-4f44-9a11-639a213a2c80"}, "_deposit": {"created_by": 1, "id": "47019", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "47019"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00047019", "sets": ["1"]}, "author_link": ["469405", "469409", "469407", "469412", "469411", "469406", "469410", "469408"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2014-04", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1/4", "bibliographicPageEnd": "440", "bibliographicPageStart": "437", "bibliographicVolumeNumber": "161", "bibliographic_titles": [{"bibliographic_title": "Radiation Protection Dosimetry"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "A thermoluminescent (TL) phosphor Li3B7O12:Cu was irradiated by a proton beam at NIRS-HIMAC in Japan. Irradiation was performed at different water-equivalent depths using range shifters made of polymethyl methacrylate. The thermoluminescent responses of Li3B7O12:Cu were analysed, focusing on the TL efficiency and glow curve. The irradiated samples were heated from room temperature to 200°C at 0.16°C s−1. The high-temperature area of the glow curve under proton irradiation changed in comparison with that under 60Co gamma-ray irradiation. The relative TL efficiency of the main peak slightly varied between 0.8 and 1.1. The relationship between the relative TL efficiency of the main peak and the high-temperature area ratio (HTR) value, the relative TL ratio of the main peak to the high-temperature area, showed approximate linearity for proton dosimetry. Using correction based on the HTR method, the TL phosphor Li3B7O12:Cu can become a useful dosimetric tool for therapeutic proton beams. ", "subitem_description_type": "Abstract"}]}, "item_8_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Oxford Journals"}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1093/rpd/ncu140", "subitem_relation_type_select": "DOI"}}]}, "item_8_relation_17": {"attribute_name": "関連サイト", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "http://rpd.oxfordjournals.org/content/161/1-4/437.full"}], "subitem_relation_type_id": {"subitem_relation_type_id_text": "http://rpd.oxfordjournals.org/content/161/1-4/437.full", "subitem_relation_type_select": "URI"}}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "古場, 裕介"}], "nameIdentifiers": [{"nameIdentifier": "469405", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "福田, 茂一"}], "nameIdentifiers": [{"nameIdentifier": "469406", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "眞正, 浄光"}], "nameIdentifiers": [{"nameIdentifier": "469407", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "若林, 源一郎"}], "nameIdentifiers": [{"nameIdentifier": "469408", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "古場 裕介", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "469409", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "福田 茂一", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "469410", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "眞正 浄光", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "469411", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "若林 源一郎", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "469412", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "THERMOLUMINESCENT RESPONSES OF Li3B7O12:Cu TO PROTON BEAM", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "THERMOLUMINESCENT RESPONSES OF Li3B7O12:Cu TO PROTON BEAM"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/47019", "pubdate": {"attribute_name": "公開日", "attribute_value": "2015-01-20"}, "publish_date": "2015-01-20", "publish_status": "0", "recid": "47019", "relation": {}, "relation_version_is_last": true, "title": ["THERMOLUMINESCENT RESPONSES OF Li3B7O12:Cu TO PROTON BEAM"], "weko_shared_id": -1}
THERMOLUMINESCENT RESPONSES OF Li3B7O12:Cu TO PROTON BEAM
https://repo.qst.go.jp/records/47019
https://repo.qst.go.jp/records/47019ce90c435-6c68-471c-a0a5-aa566c56d93e
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2015-01-20 | |||||
タイトル | ||||||
タイトル | THERMOLUMINESCENT RESPONSES OF Li3B7O12:Cu TO PROTON BEAM | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
古場, 裕介
× 古場, 裕介× 福田, 茂一× 眞正, 浄光× 若林, 源一郎× 古場 裕介× 福田 茂一× 眞正 浄光× 若林 源一郎 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | A thermoluminescent (TL) phosphor Li3B7O12:Cu was irradiated by a proton beam at NIRS-HIMAC in Japan. Irradiation was performed at different water-equivalent depths using range shifters made of polymethyl methacrylate. The thermoluminescent responses of Li3B7O12:Cu were analysed, focusing on the TL efficiency and glow curve. The irradiated samples were heated from room temperature to 200°C at 0.16°C s−1. The high-temperature area of the glow curve under proton irradiation changed in comparison with that under 60Co gamma-ray irradiation. The relative TL efficiency of the main peak slightly varied between 0.8 and 1.1. The relationship between the relative TL efficiency of the main peak and the high-temperature area ratio (HTR) value, the relative TL ratio of the main peak to the high-temperature area, showed approximate linearity for proton dosimetry. Using correction based on the HTR method, the TL phosphor Li3B7O12:Cu can become a useful dosimetric tool for therapeutic proton beams. | |||||
書誌情報 |
Radiation Protection Dosimetry 巻 161, 号 1/4, p. 437-440, 発行日 2014-04 |
|||||
出版者 | ||||||
出版者 | Oxford Journals | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1093/rpd/ncu140 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | http://rpd.oxfordjournals.org/content/161/1-4/437.full | |||||
関連名称 | http://rpd.oxfordjournals.org/content/161/1-4/437.full |