WEKO3
アイテム
{"_buckets": {"deposit": "2cca2eed-97c6-4741-bbd4-8730d2f112a6"}, "_deposit": {"created_by": 1, "id": "47006", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "47006"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00047006", "sets": ["1"]}, "author_link": ["469254", "469248", "469269", "469262", "469270", "469259", "469258", "469272", "469261", "469249", "469256", "469257", "469253", "469266", "469252", "469271", "469267", "469263", "469260", "469250", "469264", "469265", "469251", "469268", "469247", "469255"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2014-03", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "8", "bibliographicPageEnd": "1859", "bibliographicPageStart": "1852", "bibliographicVolumeNumber": "135", "bibliographic_titles": [{"bibliographic_title": "International journal of cancer"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Oncoimaging using positron emission tomography (PET) with a specific radioprobe would facilitate individualized cancer management. Evidence indicates that ectopically expressed metabotropic glutamate 1 (mGlu1) receptor independently induces melanocyte carcinogenesis, and it is therefore becoming an important target for personalized diagnosis and treatment strategies for melanomas. Here, we report the development of an oncoprotein-based PET imaging platform in melanomas for noninvasive visualization and quantification of mGlu1 with a novel mGlu1-specific radioprobe, 4-(18) F-fluoro-N-[4-[6-(isopropyl amino)pyrimidin-4-yl]-1,3-thiazol-2-yl]-N-methylbenzamide ((18) F-FITM). (18) F-FITM shows excellent pharmacokinetics, namely the dense and specific accumulation in mGlu1-positive melanomas versus mGlu1-negative hepatoma and normal tissues. Furthermore, the accumulation levels of radioactivity corresponded to the extent of tumor and to levels of mGlu1 protein expression in melanomas and melanoma metastasis. The (18) F-FITM PET imaging platform, as a noninvasive personalized diagnostic tool, is expected to open a new avenue for defining individualized therapeutic strategies, clinical trials, patient management and understanding mGlu1-triggered oncologic events in melanomas.", "subitem_description_type": "Abstract"}]}, "item_8_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Wiley-Liss"}]}, "item_8_relation_13": {"attribute_name": "PubMed番号", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "24643962", "subitem_relation_type_select": "PMID"}}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1002/ijc.28842", "subitem_relation_type_select": "DOI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0020-7136", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Xie, Lin"}], "nameIdentifiers": [{"nameIdentifier": "469247", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yui, Joji"}], "nameIdentifiers": [{"nameIdentifier": "469248", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Fujinaga, Masayuki"}], "nameIdentifiers": [{"nameIdentifier": "469249", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hatori, Akiko"}], "nameIdentifiers": [{"nameIdentifier": "469250", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamasaki, Tomoteru"}], "nameIdentifiers": [{"nameIdentifier": "469251", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kumata, Katsushi"}], "nameIdentifiers": [{"nameIdentifier": "469252", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Wakizaka, Hidekatsu"}], "nameIdentifiers": [{"nameIdentifier": "469253", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Furutsuka, Kenji"}], "nameIdentifiers": [{"nameIdentifier": "469254", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Takei, Makoto"}], "nameIdentifiers": [{"nameIdentifier": "469255", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Jin, Zhao-Hui"}], "nameIdentifiers": [{"nameIdentifier": "469256", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Furukawa, Takako"}], "nameIdentifiers": [{"nameIdentifier": "469257", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kawamura, Kazunori"}], "nameIdentifiers": [{"nameIdentifier": "469258", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Zhang, Ming-Rong"}], "nameIdentifiers": [{"nameIdentifier": "469259", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "謝 琳", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "469260", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "由井 譲二", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "469261", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "藤永 雅之", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "469262", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "羽鳥 晶子", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "469263", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山崎 友照", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "469264", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "熊田 勝志", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "469265", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "脇坂 秀克", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "469266", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "古塚 賢士", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "469267", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "武井 誠", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "469268", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "金 朝暉", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "469269", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "古川 高子", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "469270", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "河村 和紀", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "469271", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "張 明栄", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "469272", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Molecular imaging of ectopic metabotropic glutamate 1 receptor in melanoma with a positron emission tomography radioprobe (18) F-FITM.", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Molecular imaging of ectopic metabotropic glutamate 1 receptor in melanoma with a positron emission tomography radioprobe (18) F-FITM."}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/47006", "pubdate": {"attribute_name": "公開日", "attribute_value": "2014-12-22"}, "publish_date": "2014-12-22", "publish_status": "0", "recid": "47006", "relation": {}, "relation_version_is_last": true, "title": ["Molecular imaging of ectopic metabotropic glutamate 1 receptor in melanoma with a positron emission tomography radioprobe (18) F-FITM."], "weko_shared_id": -1}
Molecular imaging of ectopic metabotropic glutamate 1 receptor in melanoma with a positron emission tomography radioprobe (18) F-FITM.
https://repo.qst.go.jp/records/47006
https://repo.qst.go.jp/records/470063e355aab-8cff-44f2-a958-ac4351df4f10
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2014-12-22 | |||||
タイトル | ||||||
タイトル | Molecular imaging of ectopic metabotropic glutamate 1 receptor in melanoma with a positron emission tomography radioprobe (18) F-FITM. | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Xie, Lin
× Xie, Lin× Yui, Joji× Fujinaga, Masayuki× Hatori, Akiko× Yamasaki, Tomoteru× Kumata, Katsushi× Wakizaka, Hidekatsu× Furutsuka, Kenji× Takei, Makoto× Jin, Zhao-Hui× Furukawa, Takako× Kawamura, Kazunori× Zhang, Ming-Rong× 謝 琳× 由井 譲二× 藤永 雅之× 羽鳥 晶子× 山崎 友照× 熊田 勝志× 脇坂 秀克× 古塚 賢士× 武井 誠× 金 朝暉× 古川 高子× 河村 和紀× 張 明栄 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Oncoimaging using positron emission tomography (PET) with a specific radioprobe would facilitate individualized cancer management. Evidence indicates that ectopically expressed metabotropic glutamate 1 (mGlu1) receptor independently induces melanocyte carcinogenesis, and it is therefore becoming an important target for personalized diagnosis and treatment strategies for melanomas. Here, we report the development of an oncoprotein-based PET imaging platform in melanomas for noninvasive visualization and quantification of mGlu1 with a novel mGlu1-specific radioprobe, 4-(18) F-fluoro-N-[4-[6-(isopropyl amino)pyrimidin-4-yl]-1,3-thiazol-2-yl]-N-methylbenzamide ((18) F-FITM). (18) F-FITM shows excellent pharmacokinetics, namely the dense and specific accumulation in mGlu1-positive melanomas versus mGlu1-negative hepatoma and normal tissues. Furthermore, the accumulation levels of radioactivity corresponded to the extent of tumor and to levels of mGlu1 protein expression in melanomas and melanoma metastasis. The (18) F-FITM PET imaging platform, as a noninvasive personalized diagnostic tool, is expected to open a new avenue for defining individualized therapeutic strategies, clinical trials, patient management and understanding mGlu1-triggered oncologic events in melanomas. | |||||
書誌情報 |
International journal of cancer 巻 135, 号 8, p. 1852-1859, 発行日 2014-03 |
|||||
出版者 | ||||||
出版者 | Wiley-Liss | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0020-7136 | |||||
PubMed番号 | ||||||
識別子タイプ | PMID | |||||
関連識別子 | 24643962 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1002/ijc.28842 |