ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Comparative analysis of radon, thoron and thoron progeny concentration measurements.

https://repo.qst.go.jp/records/46872
https://repo.qst.go.jp/records/46872
2e610602-262e-41af-83d2-bb9b7cbfbe7d
Item type 学術雑誌論文 / Journal Article(1)
公開日 2014-10-21
タイトル
タイトル Comparative analysis of radon, thoron and thoron progeny concentration measurements.
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Janik, Miroslaw

× Janik, Miroslaw

WEKO 467649

Janik, Miroslaw

Search repository
Tokonami, Shinji

× Tokonami, Shinji

WEKO 467650

Tokonami, Shinji

Search repository
Kranrod, Chutima

× Kranrod, Chutima

WEKO 467651

Kranrod, Chutima

Search repository
Sorimachi, Atsuyuki

× Sorimachi, Atsuyuki

WEKO 467652

Sorimachi, Atsuyuki

Search repository
Ishikawa, Tetsuo

× Ishikawa, Tetsuo

WEKO 467653

Ishikawa, Tetsuo

Search repository
Hosoda, Masahiro

× Hosoda, Masahiro

WEKO 467654

Hosoda, Masahiro

Search repository
McLaughlin, James

× McLaughlin, James

WEKO 467655

McLaughlin, James

Search repository
Chang, Byung-Uck

× Chang, Byung-Uck

WEKO 467656

Chang, Byung-Uck

Search repository
Jae, Kim Yong

× Jae, Kim Yong

WEKO 467657

Jae, Kim Yong

Search repository
ミロソラフ ヤニック

× ミロソラフ ヤニック

WEKO 467658

en ミロソラフ ヤニック

Search repository
石川 徹夫

× 石川 徹夫

WEKO 467659

en 石川 徹夫

Search repository
抄録
内容記述タイプ Abstract
内容記述 This study examined correlations between radon, thoron and thoron progeny concentrations based on surveys conducted in several different countries. For this purpose, passive detectors developed or modified by the National Institute of Radiological Sciences (NIRS) were used. Radon and thoron concentrations were measured using passive discriminative radon-thoron detectors. Thoron progeny measurements were conducted using the NIRS-modified detector, originally developed by Zhuo and Iida. Weak correlations were found between radon and thoron as well as between thoron and thoron progeny. The statistical evaluation showed that attention should be paid to the thoron equilibrium factor for calculation of thoron progeny concentrations based on thoron measurements. In addition, this evaluation indicated that radon, thoron and thoron progeny were independent parameters, so it would be difficult to estimate the concentration of one from those of the others.
書誌情報 Journal of radiation research

巻 54, 号 4, p. 597-610, 発行日 2013-07
出版者
出版者 Oxford University Press
ISSN
収録物識別子タイプ ISSN
収録物識別子 0449-3060
PubMed番号
識別子タイプ PMID
関連識別子 23297318
DOI
識別子タイプ DOI
関連識別子 10.1093/jrr/rrs129
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:46:36.663622
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3