The dosimetric impact of respiratory breast movement and daily setup error on tangential whole breast irradiation using conventional wedge, field-in-field and irregular surface compensator techniques.

https://repo.qst.go.jp/records/46738
https://repo.qst.go.jp/records/46738
c758f1ee-21d6-47a5-9a8f-9c0838aa9733
Item type 学術雑誌論文 / Journal Article(1)
公開日 2014-03-06
タイトル
タイトル The dosimetric impact of respiratory breast movement and daily setup error on tangential whole breast irradiation using conventional wedge, field-in-field and irregular surface compensator techniques.
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Furuya, Tomohisa

× Furuya, Tomohisa

WEKO 466081

Furuya, Tomohisa

Search repository
Sugimoto, Satoru

× Sugimoto, Satoru

WEKO 466082

Sugimoto, Satoru

Search repository
Kurokawa, Chie

× Kurokawa, Chie

WEKO 466083

Kurokawa, Chie

Search repository
Ozawa, Shuichi

× Ozawa, Shuichi

WEKO 466084

Ozawa, Shuichi

Search repository
Karasawa, Kumiko

× Karasawa, Kumiko

WEKO 466085

Karasawa, Kumiko

Search repository
Sasai, Keisuke

× Sasai, Keisuke

WEKO 466086

Sasai, Keisuke

Search repository
唐澤 久美子

× 唐澤 久美子

WEKO 466087

en 唐澤 久美子

Search repository
抄録
内容記述タイプ Abstract
内容記述 To evaluate the dosimetric impact of respiratory breast motion and daily setup error on whole breast irradiation (WBI) using three irradiation techniques; conventional wedge (CW), field-in-field (FIF) and irregular surface compensator (ISC). WBI was planned for 16 breast cancer patients. The dose indices for evaluated clinical target volume (CTV(evl)), lung, and body were evaluated. For the anterior-posterior (AP) respiratory motion and setup error of a single fraction, the isocenter was moved according to a sine function, and the dose indices were averaged over one period. Furthermore, the dose indices were weighted according to setup error frequencies that have a normal distribution to model systematic and random setup error for the entire treatment course. In all irradiation techniques, AP movement has a significant impact on dose distribution. CTV(evl)D(95) (the minimum relative dose that covers 95 % volume) and V(95) (the relative volume receiving 95 % of the prescribed dose) were observed to significantly decrease from the original ISC plan when simulated for the entire treatment course. In contrast, the D(95), V(95) and dose homogeneity index did not significantly differ from those of the original plans for FIF and CW. With regard to lung dose, the effect of motion was very similar among all three techniques. The dosimetric impact of AP respiratory breast motion and setup error was largest for the ISC technique, and the second greatest effect was observed with the FIF technique. However, these variations are relatively small.
書誌情報 Journal of radiation research

巻 54, 号 1, p. 157-65, 発行日 2013-01
出版者
出版者 Oxford University Press
ISSN
収録物識別子タイプ ISSN
収録物識別子 0449-3060
PubMed番号
識別子タイプ PMID
関連識別子 22859565
DOI
識別子タイプ DOI
関連識別子 10.1093/jrr/rrs064
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:48:13.033510
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3