ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Japanese structure survey of radiation oncology i n 2009 with special reference to designated canser care hospitals

https://repo.qst.go.jp/records/46717
https://repo.qst.go.jp/records/46717
8160bc04-1b69-4bf2-94ba-1cb872494bb7
Item type 学術雑誌論文 / Journal Article(1)
公開日 2014-02-17
タイトル
タイトル Japanese structure survey of radiation oncology i n 2009 with special reference to designated canser care hospitals
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Numasaki, Hodaka

× Numasaki, Hodaka

WEKO 465812

Numasaki, Hodaka

Search repository
Nishio, Masamichi

× Nishio, Masamichi

WEKO 465813

Nishio, Masamichi

Search repository
Ikeda, Hiroshi

× Ikeda, Hiroshi

WEKO 465814

Ikeda, Hiroshi

Search repository
Sekiguchi, Kenji

× Sekiguchi, Kenji

WEKO 465815

Sekiguchi, Kenji

Search repository
Kamikonya, Norihiko

× Kamikonya, Norihiko

WEKO 465816

Kamikonya, Norihiko

Search repository
Koizumi, Masahiko

× Koizumi, Masahiko

WEKO 465817

Koizumi, Masahiko

Search repository
Tago, Masao

× Tago, Masao

WEKO 465818

Tago, Masao

Search repository
Ando, Yutaka

× Ando, Yutaka

WEKO 465819

Ando, Yutaka

Search repository
et.al

× et.al

WEKO 465820

et.al

Search repository
池田 恢

× 池田 恢

WEKO 465821

en 池田 恢

Search repository
関口 建次

× 関口 建次

WEKO 465822

en 関口 建次

Search repository
小泉 雅彦

× 小泉 雅彦

WEKO 465823

en 小泉 雅彦

Search repository
安藤 裕

× 安藤 裕

WEKO 465824

en 安藤 裕

Search repository
抄録
内容記述タイプ Abstract
内容記述 BACKGROUND:
The structure of radiation oncology in designated cancer care hospitals in Japan was surveyed in terms of equipment, personnel, patient load, and geographic distribution, and compared with the structure in other radiotherapy facilities and the previous survey.
METHODS:
The Japanese Society for Therapeutic Radiology and Oncology surveyed the national structure of radiation oncology in 2009. The structures of 365 designated cancer care hospitals and 335 other radiotherapy facilities were compared.
RESULTS:
Designated cancer care hospitals accounted for 50.0 % of all the radiotherapy facilities in Japan. The patterns of equipment and personnel in designated cancer care hospitals and the other radiotherapy facilities were, respectively, as follows: linear accelerators per facility: 1.4 and 1.0; dual-energy function: 78.6 and 61.3 %; three-dimensional conformal radiotherapy function: 88.5 and 70.0 %; intensity-modulated radiotherapy function: 51.6 and 25.3 %; annual number of patients per linear accelerator: 301.3 and 185.2; Ir-192 remote-controlled after-loading systems: 31.8 and 4.2 %; and average number of full-time equivalent radiation oncologists per facility: 1.8 and 0.8. Compared with the previous survey, the ownership ratio of equipment and personnel improved in both designated cancer care hospitals and the other radiotherapy facilities. Annual patient loads per full-time equivalent radiation oncologist in the designated cancer care hospitals and the other radiotherapy facilities were 225.5 and 247.6, respectively. These values exceeded the standard guidelines level of 200.
CONCLUSIONS: The structure of radiation oncology in designated Japanese cancer care hospitals was more mature than that in the other radiotherapy facilities. There is still a shortage of personnel. The serious understaffing problem in radiation oncology should be corrected in the future.
書誌情報 International Journal of Clinical Oncology

巻 18, 号 5, p. 775-783, 発行日 2012-10
ISSN
収録物識別子タイプ ISSN
収録物識別子 1341-9625
DOI
識別子タイプ DOI
関連識別子 10.1007/s10147-012-0468-7.
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:48:28.171452
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3