{"_buckets": {"deposit": "3bf8b667-a6ca-4bba-a411-77024331f840"}, "_deposit": {"created_by": 1, "id": "46695", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "46695"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00046695", "sets": ["1"]}, "author_link": ["465595", "465594", "465596", "465599", "465600", "465601", "465597", "465598"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2013-11", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "187", "bibliographicPageStart": "181", "bibliographicVolumeNumber": "116", "bibliographic_titles": [{"bibliographic_title": "Talanta"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "In this work, we report a rapid and highly sensitive analytical method for the determination of tellurium in soil and plant samples using sector field inductively coupled plasma mass spectrometry (SF-ICP-MS). Soil and plant samples were digested using aqua regia. After appropriate dilution, Te in soil and plant samples was directly analyzed without any separation and preconcentration. This simple sample preparation approach avoided to a maximum extent any contamination and loss of Te prior to the analysis. The developed analytical method was validated by the analysis of soil/sediment and plant reference materials. Satisfactory detection limits of 0.17 ng g-1 for soil and 0.02 ng g-1 for plant samples were achieved, which meant the developed method was applicable to studying the soil-to-plant transfer factor of Te. Our work represents the first time that data on the soil-to-plant transfer factor of Te were obtained for Japanese samples which can be used for the estimation of internal radiation dose of radioactive tellurium due to the Fukushima Daiichi Nuclear Power Plant accident.", "subitem_description_type": "Abstract"}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0039-9140", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Yang, Guosheng"}], "nameIdentifiers": [{"nameIdentifier": "465594", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Zheng, Jian"}], "nameIdentifiers": [{"nameIdentifier": "465595", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tagami, Keiko"}], "nameIdentifiers": [{"nameIdentifier": "465596", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Uchida, Shigeo"}], "nameIdentifiers": [{"nameIdentifier": "465597", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "楊 国勝", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "465598", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "鄭 建", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "465599", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "田上 恵子", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "465600", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "内田 滋夫", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "465601", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Rapid and sensitive determination of tellurium in soil and plant samples by sector-field inductively coupled plasma mass spectrometry", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Rapid and sensitive determination of tellurium in soil and plant samples by sector-field inductively coupled plasma mass spectrometry"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/46695", "pubdate": {"attribute_name": "公開日", "attribute_value": "2014-01-14"}, "publish_date": "2014-01-14", "publish_status": "0", "recid": "46695", "relation": {}, "relation_version_is_last": true, "title": ["Rapid and sensitive determination of tellurium in soil and plant samples by sector-field inductively coupled plasma mass spectrometry"], "weko_shared_id": -1}
Rapid and sensitive determination of tellurium in soil and plant samples by sector-field inductively coupled plasma mass spectrometry
https://repo.qst.go.jp/records/46695
https://repo.qst.go.jp/records/466955e38e557-6ccf-4d40-9ab7-a1cc7667a928
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2014-01-14 | |||||
タイトル | ||||||
タイトル | Rapid and sensitive determination of tellurium in soil and plant samples by sector-field inductively coupled plasma mass spectrometry | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Yang, Guosheng
× Yang, Guosheng× Zheng, Jian× Tagami, Keiko× Uchida, Shigeo× 楊 国勝× 鄭 建× 田上 恵子× 内田 滋夫 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | In this work, we report a rapid and highly sensitive analytical method for the determination of tellurium in soil and plant samples using sector field inductively coupled plasma mass spectrometry (SF-ICP-MS). Soil and plant samples were digested using aqua regia. After appropriate dilution, Te in soil and plant samples was directly analyzed without any separation and preconcentration. This simple sample preparation approach avoided to a maximum extent any contamination and loss of Te prior to the analysis. The developed analytical method was validated by the analysis of soil/sediment and plant reference materials. Satisfactory detection limits of 0.17 ng g-1 for soil and 0.02 ng g-1 for plant samples were achieved, which meant the developed method was applicable to studying the soil-to-plant transfer factor of Te. Our work represents the first time that data on the soil-to-plant transfer factor of Te were obtained for Japanese samples which can be used for the estimation of internal radiation dose of radioactive tellurium due to the Fukushima Daiichi Nuclear Power Plant accident. | |||||
書誌情報 |
Talanta 巻 116, p. 181-187, 発行日 2013-11 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0039-9140 |