WEKO3
-
RootNode
アイテム
Potential for reducing the numbers of SiPM readout surfaces of laser-processed X'tal cube PET detectors
https://repo.qst.go.jp/records/46665
https://repo.qst.go.jp/records/4666521d49c05-abb6-47e3-abe3-1af0655d8eae
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2013-12-06 | |||||
タイトル | ||||||
タイトル | Potential for reducing the numbers of SiPM readout surfaces of laser-processed X'tal cube PET detectors | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Hirano, Yoshiyuki
× Hirano, Yoshiyuki× Inadama, Naoko× Yoshida, Eiji× Nishikido, Fumihiko× Murayama, Hideo× Watanabe, Mitsuo× Yamaya, Taiga× 平野 祥之× 稲玉 直子× 吉田 英治× 錦戸 文彦× 村山 秀雄× 山谷 泰賀 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | We are developing a three-dimensional (3D) position-sensitive detector with isotropic spatial resolution, the X'tal cube. Originally, our design consisted of a crystal block for which all six surfaces were covered with arrays of multi-pixel photon counters (MPPCs). In this paper, we examined the feasibility of reducing the number of surfaces on which a MPPC array must be connected with the aim of reducing the complexity of the system. We evaluated two kinds of laser-processed X'tal cubes of 3 mm and 2 mm pitch segments while varying the numbers of the 4 * 4 MPPC arrays down to two surfaces. The sub-surface laser engraving technique was used to fabricate 3D grids into a monolithic crystal block. The 3D flood histograms were obtained by the Anger-type calculation. Two figures of merit, peak-to-valley ratios and distance-to-width ratios, were used to evaluate crystal identification performance. Clear separation was obtained even in the 2-surface configuration for the 3 mm X'tal cube, and the average peak-to-valley ratios and the distance-to-width ratios were 6.7 and 2.6, respectively. Meanwhile, in the 2 mm X'tal cube, the 6-surface configuration could separate all crystals and even the 2-surface case could also, but the flood histograms were relatively shrunk in the 2-surface case, especially on planes parallel to the sensitive surfaces. However, the minimum peak-to-valley ratio did not fall below 3.9. We concluded that reducing the numbers of MPPC readout surfaces was feasible for both the 3 mm and the 2 mm X'tal cubes. | |||||
書誌情報 |
Physics in Medicine and Biology 巻 58, 号 5, p. 1361-1374, 発行日 2013-02 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0031-9155 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1088/0031-9155/58/5/1361 |
Share
Cite as
Hirano, Yoshiyuki, Inadama, Naoko, Yoshida, Eiji, Nishikido, Fumihiko, Murayama, Hideo, Watanabe, Mitsuo, Yamaya, Taiga, 平野 祥之, 稲玉 直子, 吉田 英治, 錦戸 文彦, 村山 秀雄, 山谷 泰賀, n.d., Potential for reducing the numbers of SiPM readout surfaces of laser-processed X'tal cube PET detectors: 1361–1374 p.
Loading...